David F Young Md Pc

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 38D0627955
Address 1309 Ne 6th St, Grants Pass, OR, 97526
City Grants Pass
State OR
Zip Code97526
Phone541 479-3367
Lab DirectorDAVID YOUNG

Citation History (2 surveys)

Survey - July 31, 2024

Survey Type: Standard

Survey Event ID: RZH511

Deficiency Tags: D5217 D5217

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) records and an interview with the Laboratory Director (LD), the laboratory failed to perform biannual verification of the test KOH test slides. Findings include: 1. A review of PT records revealed no biannual verification was performed for KOH for 2023 and 2024. 2. An interview with the Laboratory Director and Office Manager confirmed these findings on 07/31/2024 @ 14:30 PM. 3. The laboratory performs approximately 10 KOH tests per year. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 15, 2020

Survey Type: Standard

Survey Event ID: EKP211

Deficiency Tags: D5217 D5417 D5417 D5217 D5401 D5401

Summary:

Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of testing personnel competency records, no written competency records could be produced for staff performing potassium hydroxide (KOH) preparations. Findings include: 1. Upon review of the CMS 116 form for renewal, it was noted that the facility had logged twenty three (23) KOH preps performed on page four (4) of the document. 2. When asked for the required written documentation of bi-annual verification for staff performing KOH preps, none could be provided during survey 07/15/2020. 3. During a phone converstaion with the Laboratory Director on 07/15/2020 at approximately 12:00 pm, he confirmed that the laboratory had failed to perform bi-annual verification for staff performing KOH preps. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based upon review of the procedure manual for Histopathology tissues and slides for this laboratory, there was no written procedure for the process of sending out "Slow Mohs" specimens. Findings include: 1. Upon review of the procedure manual, it was Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- noted that a written procedure for the process of specimens sent for Slow Mohs tissues collected on site was lacking. 2. Upon interview with the back office manager during survey 07/15/2020 at approximately 1230 pm, she confirmed no written procedure could be produced. 3. No procedure on what to do after the results / diagnosis for the Slow Mohs specimens were received could be produced as well. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on physical inspection of reagent and discussion with staff, the potassium hydroxide (KOH) used to perform KOH mounts was out dated. Findings include: 1. The KOH solution provided to me during survey outdated 09/09/2010. -- 2 of 2 --