Dena'Ina Wellness Center

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 02D0708909
Address 508 Upland Street, Kenai, AK, 99611
City Kenai
State AK
Zip Code99611
Phone(907) 335-7500

Citation History (1 survey)

Survey - March 29, 2018

Survey Type: Special

Survey Event ID: SNKO11

Deficiency Tags: D2107 D2016

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of proficiency testing records, the laboratory unsuccessfully participated in proficiency testing (PT) for the specialty Endocrinology, and the Thyroid Stimulating Hormone analyte. See D2017 D2107 ENDOCRINOLOGY CFR(s): 493.843(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of proficiency testing records, the laboratory failed to achieve satisfactory proficiency testing performance for the specialty Endocrinology and the Thyroid Stimulating Hormone (TSH) analyte in two of three testing events. Findings: 1. The laboratory is subscribed to the American Proficiency Institute Chemistry Core proficiency testing program. 2. The laboratory received the following scores: Endocrinology: 2017 Third Testing Event: 66% 2018 First Testing Event: 40% TSH: 2017 Third Testing Event: 0% 2018 First Testing Event: 0% -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access