Dermatology Associates & Surgery Center Williamson

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 51D2189388
Address 150 E Second Avenue, Williamson, WV, 25661
City Williamson
State WV
Zip Code25661
Phone(304) 235-5780

Citation History (1 survey)

Survey - December 17, 2020

Survey Type: Standard

Survey Event ID: 1E5011

Deficiency Tags: D3001 D5403 D5403

Summary:

Summary Statement of Deficiencies D3001 FACILITIES CFR(s): 493.1101(a)(1) The laboratory must be constructed, arranged, and maintained to ensure the space, ventilation, and utilities necessary for conducting all phases of the testing process. This STANDARD is not met as evidenced by: Based on a review of the laboratory written policies and procedures (P&P), the Safety Data Sheets (SDS) for the chemical inventory, a tour of the laboratory, and an interview with the laboratory manager, the laboratory failed to ensure a ventilation system that removes vapors and fumes from the use of chemicals for the processing of MOHs specimens. Findings: 1. A review of the written P&P identified a "Chemical Hygiene Plan" that listed the workplace chemicals and the PPE required. The PPE listed as required for CitraClear and Select Eosin included "respiratory protection" and "vent". 2. A review of P&P identified a "Air Vent/Fume Hood Policy" that stated "The air vent or fume hood should be turned on as soon as the lab is open for operation, should remain on during operating hours." 3. A tour of the laboratory identified no air ventilation system or fume hood in the small space that the processing of slides with Select Eosin and CitraClear occur. 4. A review of SDS sheets for CitraClear and Select Eosin identified both chemicals as having Hazard Statements and Precautionary Statements of "do not breathe vapors". 5. During an interview with the laboratory manager, on 12/17/20 at approximately 10:40 AM, the laboratory manager stated there was no ventilation system or fume hood for the laboratory. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access