Dermatology Consultants Pc

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 11D0258633
Address 3280 Howell Mill Road, Nw, Suite 101, Atlanta, GA, 30327
City Atlanta
State GA
Zip Code30327
Phone(404) 351-7546

Citation History (2 surveys)

Survey - September 16, 2019

Survey Type: Standard

Survey Event ID: 0WI811

Deficiency Tags: D5209 D5291 D0000 D5217

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on September 16, 2019. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: After a review of the procedure manual, personnel records and an interview with the clinic administrator, it was determined that the laboratory did not have a comprehensive competency assessment policy with CLIA standards for its testing personnel specific to the specialty of Histopathology. Findings include: 1.) Testing Personnel (TP) record review revealed there was not a competency assessment policy that contained the six (6) CLIA criteria and no annual competencies performed on TPs #2 and #3 (CMS 209) specific to Histopathology (Mohs) proccesses in 2017, 2018 and 2019. 2.) The clinic administrator confirmed on September 16, 2019 , at approximately, 12:15 pm, in the conference room, that the laboratory did not have a competency assessment policy containing the six (6) CLIA criteria specific to Histopathology and did not perform annual competencies for TPs #2 and #3 (CMS 209) in 2017, 2017 and 2019.. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on Quality Control(QC) slides peer review documents and an interview with the clinic administrator, the laboratory failed to proof that peer reviews were done at least twice a year in 2018. Findings include: 1.) Peer review documents revealed that there were no (QC) slides sent out for review at least twice annually in 2018. 2.) An interview with the histotech and clinic administrator, in the conference room, at approximately 12:17 pm, on September 16, 2019 confirmed that the laboratory had no proof that (QC) slide peer review was completed at least twice annually in 2018. D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. This STANDARD is not met as evidenced by: A review of the procedure manual and an interview with the clinic administrator confirmed that the laboratory failed to have a Quality Assurance (QA) policy specific to the specialty of Histopathology in 2017, 2018 and 2019. Findings include: 1.) Procedure manual review revealed that the clinic does not have a (QA) policy specific to the specialty of Histopathology for 2017, 2018 and 2019. 2.) An interview with the histotech and clinic administrator, at approximately at 12:20 pm, on September 16, 2019, in the conference room, confirmed that the clinic did not have a written QA policy specific to Histopathology for years 2017, 2018 and 2019. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 6, 2019

Survey Type: Complaint

Survey Event ID: H5B311

Deficiency Tags: D0000 D3011

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on June 6, 2019. The laboratory was found to be not in compliance with all applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on surveyor observation and an interview with office manager, the laboratory failed to ensure safety procedures for proper storage of medicine, patient samples, and laboratory supplies in a designated area. The findings include: 1. An observation of one of the laboratory refrigerators revealed that beverages and food items were being stored in the same area as the Cosentyx prefilled injectable, previously tested patient samples, and other laboratory supplies, which affects the integrity, quality, and purity of the products. 2. The office manager confirmed on June 6, 2019 at 10:45 AM in the laboratory that beverages and food were being stored in the same refrigerator as laboratory supplies and other medicines. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access