Dermatology & Skin Surgery Specialists Of Arizona

CLIA Laboratory Citation Details

2
Total Citations
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 03D2089517
Address 8415 N Pima Rd Ste 212, Scottsdale, AZ, 85258
City Scottsdale
State AZ
Zip Code85258
Phone(480) 434-6600

Citation History (2 surveys)

Survey - September 24, 2024

Survey Type: Standard

Survey Event ID: 762911

Deficiency Tags: D5473

Summary:

Summary Statement of Deficiencies D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on lack of Quality Control (QC) documentation for two out of five testing dates reviewed during the survey and interview with the facility personnel, the laboratory failed to document the acceptability of Hematoxylin & Eosin (H&E) staining materials each day of use, for intended reactivity to ensure predictable staining characteristics. Findings include: 1. No documentation of the H&E stain acceptability was presented for review for the Mohs procedures that occurred on 3/31/23 and 9/26 /23. 2. Nine Mohs cases were performed on 3/31/23 and six Mohs cases were performed on 9/26/23. 3. The facility personnel interviewed on 9/24/24 at 8:50 AM confirmed the laboratory failed to document the H&E stain acceptability on the testing dates indicated above, for intended reactivity to ensure predictable staining characteristics. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 20, 2022

Survey Type: Standard

Survey Event ID: 89Y411

Deficiency Tags: D5413 D5433

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on lack of temperature records for review and interview with the facility personnel, the laboratory failed to monitor and document the room temperature where dermatopathology reagents are utilized and stored and failed to monitor and document the temperature of the cryostat used in conjunction with Mohs testing during 2021. Findings include: 1. The laboratory processes and interprets dermatopathology slides in conjunction with Mohs surgery, with an approximate annual test volume of 2,000. 2. No room temperature documentation was presented for review from 2021 to indicate the laboratory monitored and documented the temperature of the room each day of patient testing, where dermatopathology reagents are utilized and stored. 3. No documentation was presented for review to indicate the laboratory monitored and documented the cryostat temperature each day of patient testing during 2021. 4. The facility personnel confirmed that the laboratory failed to monitor and document the cryostat temperature and the room temperature of the laboratory where reagents are stored and used for patient testing during 2021. D5433 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(b)(1) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- For equipment, instruments, or test systems developed in-house, commercially available and modified by the laboratory, or maintenance and function check protocols are not provided by the manufacturer, the laboratory must establish a maintenance protocol that ensures equipment, instrument, and test system performance that is necessary for accurate and reliable test results and test result reporting. The laboratory must perform and document the maintenance activities specified in paragraph (b)(1)(i) of this section. This STANDARD is not met as evidenced by: Based on review of the laboratory's established microscope maintenance policy and interview with the facility personnel, the laboratory failed to perform and document the microscope maintenance as defined by policy during 2020 and 2021. Findings include: 1. The laboratory's policy titled, "Microscope Use Protocol Quality Control" indicates that the microscope stage and ocular eyepieces are to be cleaned every 6 months or sooner if needed, grounding check is monitored when service is completed and the ocular micrometer is calibrated as needed. 2. No documentation was presented for review to indicate the laboratory performed the microscope maintenance as indicated above during 2020 and 2021. The microscope was used for patient testing regularly during that time period. 3. The facility personnel confirmed that the laboratory failed to perform maintenance on the microscope as indicated in policy during the timeframe indicated above. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access