Digestive Disease Center Histology Lab

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 33D0960211
Address 400 Westage Business Ctr Dr, Ste 104, Fishkill, NY, 12524
City Fishkill
State NY
Zip Code12524
Phone845 231-5389
Lab DirectorNICOS NICOLAOU

Citation History (1 survey)

Survey - March 19, 2024

Survey Type: Standard

Survey Event ID: F8R111

Deficiency Tags: D0000 D5413

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA exempt-state validation survey was conducted at Digestive Disease Center - Histology on March 19, 2024, by the CMS New York CLIA Branch Location federal surveyor. The laboratory was surveyed under 42 CFR part 493 CLIA regulations. The laboratory is in compliance with condition-level CLIA requirements. The following standard-level deficiency was found during the CLIA exempt-state validation survey performed on March 19, 2024. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on the lack of laboratory humidity records, and interview with histology supervisor, the laboratory failed to document relative humidity conditions in the histology laboratory from 2022 to 2024. Finding Include: 1. The Agilent Technologies Dako PT Link's manufacture manual stated a an environmental requirement of 25 - 85% relative humidity. 2. The Tissue-Tek VIP 6 AI Tissue Processor manual stated an environmental requirement of 30 -85% relative humidity. 3. The Olympus BX41system microscope instructions, 8. operating environment states, maximum relative humidity 80%. 4. On the day of survey, March 19, 2024 the laboratory could not provide documentation of humidity conditions monitored in the histology Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- laboratory from 2022 to 2024. 5. The histology supervisor and laboratory director confirmed relative humidity conditions was being monitored but not documented in the histology laboratory on March 19, 2024 at 12: 50 PM. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access