Direct Path Services, P C

CLIA Laboratory Citation Details

2
Total Citations
11
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 23D2063166
Address 30200 Telegraph Road Suite 405, Bingham Farms, MI, 48025
City Bingham Farms
State MI
Zip Code48025
Phone(248) 220-4425

Citation History (2 surveys)

Survey - February 7, 2022

Survey Type: Standard

Survey Event ID: LV2811

Deficiency Tags: D5217 D5217 D5417 D6168 D6171 D3039 D5417 D6168 D6171

Summary:

Summary Statement of Deficiencies D3039 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(5) Quality system assessment records. Retain all laboratory quality system assessment records for at least 2 years. This STANDARD is not met as evidenced by: . Based on record review and interview with the Manager, the laboratory failed to retain

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 4, 2020

Survey Type: Standard

Survey Event ID: L6X911

Deficiency Tags: D5429 D5429

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: A Based on document review and interview with the Laboratory Director (LD) and the Operations Manager (OM), the laboratory failed to perform and document room temperature and humidity readings for 2 (February 2018 and February 2019) of 2 years. Findings include: 1. Document review revealed a lack of documentation of the room temperature and humidity readings in the main laboratory, the Laboratory Director's office, and the conference room where microscopes are located. 2. Review of the "Olympus BX41" and the "Biological Microscope M Series" instructions revealed the operating environment should be as follows: a. Olympus BX41 - room temperature 5-40 degrees C / 41-104 degrees F with a relative humidity 80% b. M Series - room temperature 0-40 degrees C and a relative humidity of 85%. 3. During the interview on 2/4/2020 at 11:13 am, the LD and OM confirmed the temperature and humidity readings were not performed and documented. B Based on document review and interview with the Laboratory Director (LD) and the Operations Manager (OM), the laboratory failed to perform and document pipette calibrations for 2 (February 2018 and February 2019) of 2 years in use. Findings include: 1. Review of "Diamond Instruction Manual" under the calibration section states "It is recommended to check the calibration as least once a year, for regularly used pipette." 2. Document review revealed a lack of documentation for pipette calibrations for 2 (February 2018 and February 2019) of 2 years. 3. During the interview on 2/4/2020 at 11:20 am, the LD and OM confirmed the pipettes were not calibrated regularly. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access