Doctors Care - Cayce

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 42D0248630
Address 977 Knox Abbott Drive, Cayce, SC, 29033
City Cayce
State SC
Zip Code29033
Phone(888) 843-3719

Citation History (2 surveys)

Survey - May 30, 2019

Survey Type: Special

Survey Event ID: 0R7I11

Deficiency Tags: D2121 D6016 D2130 D2016 D6000

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: During the proficiency test desk review performed on 05/30/2019, based on review of CASPER report 155D and graded reports from American Proficiency Institute (API), it was determined that the laboratory failed to successfully participate in proficiency testing for the specialty of hematology, the analyte white blood cell differential (WBC Diff) for three consecutive proficiency testing events reviewed (2017, Event 1 and 2018, Events 2 and 3). See D2121 and D2130. D2121 HEMATOLOGY CFR(s): 493.851(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: During a proficiency testing desk review performed on 05/30/2019, based on review of the CASPER report 155D and laboratory proficiency testing records (graded copies from American Proficiency Institute), it was determined that the laboratory failed to attain a score of at least 80 percent in proficiency testing for the specialty of hematology, the analyte white blood cell differential (WBC Diff) for three consecutive proficiency testing events (2017, Event 1 and 2018 Event 2 and 3). The findings include: 1. Review of CASPER report 155D revealed the following WBC Diff proficiency scores for your laboratory: a. 2017, Event 1: 0% b. 2018, Event 2: 73% c. 2018, Event 3: 73% 2. The scores were confirmed upon review of the graded API results. Scores less than 80% for these analytes indicate failure or unsatisfactory performance. A failure of the analytes for two consecutive or two out of three testing events is scored as unsuccessful. A failure of the analyte for three consecutive or three out of four/five events is scored as a repeat unsuccessful. D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: During the proficiency test desk review performed on 05/30/2019, based on review of CASPER report 155D and graded American Proficiency Institute results, it was determined that the laboratory failed to achieve satisfactory performance for the analyte WBC Diff in three consecutive testing events (2017, Event 1 and 2018, Events 2 and 3) resulting in unsuccessful proficiency testing performance. See D2121. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: During the proficiency testing desk review performed on 05/30/2019, based on review of CASPER report 155D and graded reports from API, the laboratory director failed to ensure proficiency testing for WBC Differential was performed as required by 42 CFR, Part 493.801 (see D2016, D2130, and D6016). D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform -- 2 of 3 -- test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: During the proficiency testing desk review on 05/30/2019, based on CASPER report 155D review and American Proficiency Institute graded report review, the laboratory director failed to ensure the laboratory attained a result of 80% for white blood cell differential, specialty of hematology. The laboratory failed three consecutive proficiency testing events(2017, Event 1, and 2018, Events 2 and 3). -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 27, 2018

Survey Type: Standard

Survey Event ID: 2SF311

Deficiency Tags: D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: During an onsite recertification survey on 06/27/2018, based on laboratory procedure manual review, laboratory room temperature record review, and staff interview, it was determined that the laboratory failed to document acceptable room temperatures between August 4, 2017 through April 21, 2018. Findings include: 1. The laboratory procedure manual had a required room temperature range between 64 and 90 degrees Celsius. 2. Review of the laboratory's temperature records revealed that room temperatures were not recorded for a total of 9 days between August 4, 2017 through April 21, 2018. There was no

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access