Dothan Hematology And Oncology Pc

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 01D0687538
Address 287 Healthwest Drive, Dothan, AL, 36303
City Dothan
State AL
Zip Code36303
Phone(334) 792-9500

Citation History (2 surveys)

Survey - September 13, 2022

Survey Type: Standard

Survey Event ID: F2XV11

Deficiency Tags: D5407 D5775 D6013 D6036 D6045

Summary:

Summary Statement of Deficiencies D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on a review of the Beckman Coulter DxH 520 Operator's Manual, and interviews with Testing Personnel #1, the surveyor determined the Laboratory Director failed to document his review and approval (as indicated by signature and date) for one of one new procedures used by the testing personnel on the new Hematology instruments. The findings include: 1. A review of the Beckman Coulter DxH 520 Operator's Manual, "Instructions for Use" revealed no signature and date on the procedures to indicate the the Laboratory Director's review and approval. 2. A review of new laboratory instrumentation revealed two new Beckman Coulter (B-C) DxH-520 Hematology analyzers: A) The "Top" analyzer (SN BD060566) was installed 12/15/2020; patient CBC (Complete Blood Count) testing began 3/19/2021. B) The "Bottom" analyzer (SN BD070624) was installed 4/19/2021; patient CBC testing began 4/19/2021. 3. During an interview and review of the manual on 9/13 /2022 5:15 PM, Testing Personnel #1 confirmed the above findings. . D5775 COMPARISON OF TEST RESULTS CFR(s): 493.1281(a)(c) (a) If a laboratory performs the same test using different methodologies or instruments, or performs the same test at multiple testing sites, the laboratory must have a system that twice a year evaluates and defines the relationship between test results using the different methodologies, instruments, or testing sites. (c) The laboratory must document all test result comparison activities. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on a review of comparison data between the two Beckman Coulter (B-C) DxH- 520 Hematology analyzers and an interview with Testing Personnel #1, the laboratory failed to ensure the differences in results between the two instruments did not exceed acceptable performance limits on five out of six studies between 6/29/2021 and 6/9 /2022. The findings include: 1. A review of records comparing results between the two B-C DxH-520 Hematology analyzers revealed the laboratory ran two samples on both instruments semi-annually, documented the results and calculated the CV (Coefficient of Variation) to demonstrate precision. The chart specified the CV Limits for all CBC (Complete Blood Count) parameters, with the question, "Acceptable?" on the bottom line. 2. A further review of the comparison charts revealed the laboratory had answered "yes" to the "Acceptable?" question on all the charts, however the surveyor noted the following: A) 6/29/2021 Sample #1: One of nine parameters unacceptable B) 6/29/2021 Sample #2: Three of nine parameters unacceptable C) 12 /28/2021 Sample #1: Two of nine parameters unacceptable D) 6/09/2022 Sample #1: Eight of nine parameters unacceptable E) 6/09/2022 Sample #2: Three of nine parameters unacceptable The surveyor noted there was no evidence of review of the comparison studies, and the laboratory further failed to implement an investigation and

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 6, 2021

Survey Type: Standard

Survey Event ID: FP9S11

Deficiency Tags: D2009 D5437

Summary:

Summary Statement of Deficiencies D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on a review of College of American Pathologists (CAP) Proficiency Testing (PT) records and an interview with Testing Personnel #1, the Laboratory Director and Testing Personnel failed to sign the attestation statement for eight out of eight 2018 - 2020 Hematology PT events. The findings include: 1. A review of CAP PT records revealed the attestation statements for 2018 FH2 - B, 2018 FH2 - C, 2019 FH2 - A, 2019 FH2 - B, 2019 FH2 - C, 2020 FH2 - A, and 2020 FH2 - B were not signed by the Laboratory Director/delegate and the testing personnel. Also, 2020 FH2 - C was not signed by the Laboratory Director. 2. During an interview with Testing Personnel #1 on 01/06/2021 at 12:55 PM, the surveyor reviewed the instructions on the attestation statement which specified the Laboratory Director and testing personnel must physically sign the document. Testing Personnel #1 explained once the laboratory began entering the results electronically, they had not realized signing the statement was still required. . D5437 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(a) Unless otherwise specified in this subpart, for each applicable test system the laboratory must perform and document calibration procedures-- (1) Following the manufacturer's test system instructions, using calibration materials provided or specified, and with at least the frequency recommended by the manufacturer; (2) Using the criteria verified or established by the laboratory as specified in 493.1253(b) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (3)-- (2)(i) Using calibration materials appropriate for the test system and, if possible, traceable to a reference method or reference material of known value; and (2)(ii) Including the number, type, and concentration of calibration materials, as well as acceptable limits for and the frequency of calibration; and (3) Whenever calibration verification fails to meet the laboratory's acceptable limits for calibration verification. This STANDARD is not met as evidenced by: Based on reviews of the Beckman Coulter AcT diff 2 Hematology analyzer Operator's Manual, calibration and quality control (QC) records, and interviews with Testing Personnel #1, the laboratory failed to follow the manufacturer's instructions to verify calibrations by running quality controls (QC), for ten out of eleven calibrations performed on the two Hematology analyzers in 2018 - 2020. In addition, the laboratory failed to ensure at least two levels of quality control were performed and acceptable, prior to analyzing patient specimens and reporting the results on five out of the eleven days the instrument was calibrated. The findings include: 1. During the entrance tour on 1/6/2021 at approximately 11:30 AM, Testing Personnel #1 stated the only test performed on site were CBC's (Complete Blood Counts) on two Beckman Coulter AcT diff 2 Hematology analyzers: SN (Serial Number) BA25346 (Top analyzer) and SN BA25347 (Bottom analyzer). 2. A review of the Hematology calibration records revealed the following: A) 09/07/2018 at 1:14 PM: Calibration on the "Top" AcT diff 2 analyzer B) 03/05/2019 at 3:52 PM: Calibration on the "Bottom" AcT diff 2 analyzer C) 03/05/2019 at 5:23 PM: Calibration on the "Top" AcT diff 2 analyzer D) 09/16/2019 at 4:44 PM: Calibration on the "Bottom" AcT diff 2 analyzer E) 09/24/2019 at 3:24 PM: Calibration on the "Top" AcT diff 2 analyzer F) 03/17 /2020 at 10:06 AM: Calibration on the "Bottom" AcT diff 2 analyzer G) 03/17/2020 at 3:00 PM: Calibration on the "Top" AcT diff 2 analyzer H) 06/17/2020 at 3:20 PM: Calibration on the "Bottom" AcT diff 2 analyzer I) 07/23/2020 at 2:02 PM: Calibration on the "Top" AcT diff 2 analyzer J) 09/28/2020 at 2:15 PM: Calibration on the "Bottom" AcT diff 2 analyzer 3. A review of the QC records for the above dates revealed QC was only performed in the morning at approximately 7:00 AM each day. 4. A review of the Coulter AcT diff 2 Analyzer Operator's Guide, under the CALIBRATION section on page 5-18 revealed, "...17. Verify calibration by running 4C PLUS Cell Control. ..." 5. A review of the patient logs revealed patient CBC's were performed and results reported on five calibration days, as follows: A) 03/05 /2019 4:00 - 4:22 PM: 5 patient CBC's were run on the "Bottom" AcT diff 2 analyzer B) 09/24/2019 3:31 - 3:37 PM: 2 patient CBC's were run on the "Top" AcT diff 2 analyzer C) 03/17/2020 11:58 AM - 2:38 PM: 14 patient CBC's were run on the "Bottom" AcT diff 2 analyzer D) 7/23/2020 at 2:13 PM: 1 patient CBC was run on the "Top" AcT diff 2 analyzer E) 9/28/2020 2:25 - 2:52 PM: 3 patient CBC's were run on the "Bottom" AcT diff 2 analyzer There was no documentation of QC performance after the calibrations and before the patient CBC testing. 6. During an interview on 1/6 /2020 at 1:15 PM, Testing Personnel #1 confirmed the laboratory had not performed QC after the calibrations on the above dates, stating QC was not run until the following morning. SURVEYOR ID #32558 Licensure and Certification Surveyor -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access