Dr Thomas P Lenns, Llc

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 42D2103364
Address 89 Main Street, Hilton Head Island, SC, 29926
City Hilton Head Island
State SC
Zip Code29926
Phone(877) 888-5565

Citation History (1 survey)

Survey - November 26, 2018

Survey Type: Standard

Survey Event ID: FJK011

Deficiency Tags: D2016 D2087 D5413

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: During an onsite recertification survey on 11/26/2018, based on review of CASPER Report 155D and proficency testing results from College of American Pathologists (CAP), the laboratory failed to successfully participate in proficiency testing for the sub-specialty of routine chemistry, the analyte high densilty lipoproteins (HDL), for two consecutive proficiency events (2018, Events A and B). See D2087. D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: During an onsite recertification survey performed on 11/26/2018, based on the CASPER 155D report review and onsite proficiency testing results review from CAP, the laboratory failed to attain a satisfactory score of at least 80% for HDL for two consecutive proficiency testing events. Findings include: 1. The CASPER 155D report revealed the following scores for HDL: a. 2018, Event A: 0% b. 2018, Event B: 40% 2. The scores were confirmed by onsite review of the graded CAP results. Scores less than 80% for this analyte indicates unsatisfactory performance. A failure of this analyte for two consecutive or two out of three consecutive testing events is scored as unsuccessful. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: During an onsite recertification survey on 11/26/2018, based on the Access 2 chemistry analyzer operator's manual review, laboratory humidity record review, and staff interview, it was determined that the laboratory failed to maintain acceptable humidity recordings for a total of 86 of 528 days reviewed from December 2016 to November 2018. Findings include: 1. Review of the Access 2 chemistry analyzer operator's manual revealed that performance is only guaranteed from the instrument in an operating environment of 20 to 80 percent humidity. 2. Review of the laboratory's humidity recordings revealed that the laboratory reached less than 20 percent humidity for a total of 86 of 528 days reviewed from December 2016 to November 2018. There was no

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access