Dupage County Diagnostics Llc

CLIA Laboratory Citation Details

2
Total Citations
25
Total Deficiencyies
23
Unique D-Tags
CMS Certification Number 14D2252339
Address 1315 Butterfield Rd - Unit 200, Downers Grove, IL, 60515
City Downers Grove
State IL
Zip Code60515
Phone(630) 541-5031

Citation History (2 surveys)

Survey - October 7, 2024

Survey Type: Complaint

Survey Event ID: PXL111

Deficiency Tags: D2007 D3000 D3005 D3037 D5213 D5305 D5400 D5401 D5411 D5415 D5423 D5455 D6076 D6086 D6093 D6098 D6102 D8100 D8103

Summary:

Summary Statement of Deficiencies D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods This STANDARD is not met as evidenced by: Based on review of laboratory records, lack of documentation and interview with the technical supervisor (TS), the laboratory failed to perform American Proficiency Institute (API) proficiency testing (PT) sub-specialty virology samples (SARS-CoV-2, Influenza A, Influenza B and Respiratory Syncytial Virus (RSV)) with the laboratory's regular patient workload for five of five Microbiology PT Events from Event 1, 2023 to Event 2, 2024. Findings include: 1. Review of the "Dupage County Diagnostics Proficiency Testing" policy revealed the following information: " ...5. PT samples should be tested in the same manner as the patient's sample ...the lab director (or the designee) are required to attest that the PT samples were tested I the same manner as patient's samples." 2. Review of the laboratory's API PT instrument run printouts for Microbiology Events 1, 2, and 3, 2023 and Microbiology Events 1 and 2, 2024 revealed no patient samples included on the PT runs. a) API 2023 Microbiology - Event 1: Samples: COV - 01 (SARS-CoV-2), COV - 02 (SARS-CoV-2), COV - 03 (SARS-CoV-2), COV - 04 (SARS-CoV-2) b) API 2023 Microbiology - Event 2: Samples: COV - 03 (SARS-CoV-2), COV - 04 (SARS-CoV-2) c) API 2023 Microbiology - Event 3: Samples: COV - 05 (SARS-CoV-2), COV - 06 (SARS-CoV- 2) d) API 2024 Microbiology - Event 1: Samples: SAR - 01 (SARS-CoV-2), SAR - 02 (SARS-CoV-2) e) API 2024 Microbiology - Event 2: Samples: SAR - 06 (SARS-CoV- 2), SAR - 07 (SARS-CoV-2) Influenza A (SFR-06, SFR-07, SFR-08, SFR-09, SFR- 10) Influenza B (SFR-06, SFR-07, SFR-08, SFR-09, SFR-10) RSV (SFR-06, SFR-07, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 12 -- SFR-08, SFR-09, SFR-10) SARS-CoV-2 (SFR-06, SFR-07, SFR-08, SFR-09, SFR- 10) 3. On 10/07/2024, at 4:27 p.m., the TS confirmed the PT was not peformed with patient samples. D3000 FACILITY ADMINISTRATION CFR(s): 493.1100 Each laboratory that performs nonwaived testing must meet the applicable requirements under 493.1101 through 493.1105, unless HHS approves a procedure that provides equivalent quality testing as specified in Appendix C of the State Operations Manual (CMS Pub. 7). (a) Reporting of SARS-CoV-2 test results During the Public Health Emergency, as defined in 400.200 of this chapter, each laboratory that performs a test that is intended to detect SARS-CoV-2 or to diagnose a possible case of COVID-19 (hereinafter referred to as a "SARS-CoV-2 test") must report SARS-CoV-2 test results to the Secretary in such form and manner, and at such timing and frequency, as the Secretary may prescribe. This CONDITION is not met as evidenced by: Repeat Deficiency Based on surveyor's direct observation, laboratory records, and interview with the technical supervisor (TS), the laboratory failed to maintain a uni- directional workflow for molecular amplification procedures to prevent potential cross-contamination in specimen processing, preparation, amplification, and detection of SARS-CoV-2, Influenza A, Influenza B, and Respiratory Syncytial Virus (RSV) from December 2022 through 2024, affecting over 77,500 patient tests (Refer to D3005) and failed to retain American Proficiency Institute (API) proficiency testing (PT) records for two years (Refer to D3037). D3005 FACILITIES CFR(s): 493.1101(a)(3) Molecular amplification procedures that are not contained in closed systems have a uni-directional workflow. This must include separate areas for specimen preparation, amplification and product detection, and, as applicable, reagent preparation. This STANDARD is not met as evidenced by: Repeat Deficiency Based on surveyor's direct observation, laboratory records, and interview with the technical supervisor (TS), the laboratory failed to maintain a uni- directional workflow for molecular amplification procedures to prevent potential cross-contamination in specimen processing, preparation, amplification, and detection of SARS-CoV-2, Influenza A, Influenza B, and Respiratory Syncytial Virus (RSV) from December 2022 through 2024, affecting over 77,500 patient tests. Findings include: 1. Review of the "Dupage County Diagnostics Molecular Testing, Quality Control and Quality Assessment Policy" revealed the following information: "Avoiding Contamination Policy: ...Avoid Cross Contamination between specimens ... ...two separate areas will be designated for PCR testing: Pre - and Post - PCR ... ... Sample Preparation and RNA Extraction will take place in Biosafety Cabinet (BSC) ... ...We will have one dedicated refrigerator/freezer for kit storage and another for storage of samples ... ...Tubes will be discarded after PCR amplification and analysis is complete. It will not be opened or will they be taken into the pre-PCR room ..." 2. On 10/07/2024, at 2:30 p.m., direct observation during a laboratory tour with the TS revealed the laboratory failed to maintain a uni-directional workflow for the molecular -- 2 of 12 -- amplification of SARS-CoV-2, Influenza A, Influenza B, and Respiratory Syncytial Virus (RSV): a. The transfer of patient samples to the patient testing plates and the addition of positive and negative control samples to the patient testing plates all performed in one BSC (Baker SterilGARD SN: 127773); b. Transfer pipettes found on a storage shelf outside of the processing cabinet; c. Unmarked reagents, Laboratory B American Proficiency Institute (API) proficiency testing (PT) samples (SARS-CoV- 2 liquid molecular CAT # 385 - Microbiology Events 1, 2, and 3, 2023, and five SARS-CoV-2 positive patient samples (ID Numbers: 52515, 80435, 62587, 81077 and 81083) stored in one freezer (Frigidaire SN:1K14671595). 3. On 10/07/2024, at 2: 30 p.m., the TS confirmed the laboratory did not follow uni-directional flow. D3037 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(4) Proficiency testing records. Retain all proficiency testing records for at least 2 years. This STANDARD is not met as evidenced by: Based on review of laboratory records, lack of documentation and interview with the technical supervisor (TS), the laboratory failed to retain American Proficiency Institute (API) proficiency testing (PT) records for one of five Microbiology PT events (Event 2) reviewed in 2024. Findings include: 1. Review of the "Dupage County Diagnostics Proficiency Policy" revealed the following guidelines: " - ...The laboratory's PT record keeping will include: All PT test records, such as instrument tapes and logs, PT Result Form, PT Attestation Statement and PT score Report. - ... All PT records will be retained for a minimum of two years ..." 2. Review of the submitted laboratory API PT instrument runs for Microbiology Event 2, 2024, revealed the surveyor was unable to determine the date of PT testing and the analyzer utilized to perform the following API PT samples: 2024 Event 2: SAR-06, SAR-07, SFR-06, SFR-07, SFR-08, SFR-09 SFR-10 (no documentation submitted) 3. On 10/07 /2024, at 1:30 p.m., the TS confirmed the laboratory faied to provide instrument run data for API PT Microbiology Event 2. D5213 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(1) The laboratory must verify the accuracy of any analyte or subspecialty without analytes listed in subpart I of this part that is not evaluated or scored by a CMS- approved proficiency testing program. This STANDARD is not met as evidenced by: Based on review of laboratory records and interview with the technical supervisor (TS), the laboratory failed to examine the self-graded performance of sub-specialty virology analyte (COV - 05, SARS-CoV-2) on the American Proficiency Institute (API) proficiency testing (PT) Microbiology Event 3, 2023. Findings include: 1. Review of the "Dupage County Diagnostics Proficiency Testing" policy revealed the following information: " ...10. Upon receipt of evaluation results, review and investigate and document the finding for all unacceptable results. Self-grade specimens that were not graded by comparing expected values and/or peer group results." 2. Review of the laboratory's result sheet marked, "Proficiency Test 2023 Microbiology 3rd Event - Reagent Kit Lot: COVID20230419" revealed the following information: Sample ID - COV-05 Result - NEGATIVE Expected Result - POSITIVE -- 3 of 12 -- 3. Review of the API "Comparative Evaluation 2023 Microbiology - 3rd Event" report revealed the following information: Analyte / Method: SARS-CoV-2 Sample: COV-05 Reported Result: Not Detected Expected Result: See Data Summary Performance: Not Graded 4. Review of the API PT "2023 Microbiology - 3rd Event Performance Review and

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 20, 2023

Survey Type: Standard

Survey Event ID: OTZR11

Deficiency Tags: D3000 D3005 D5787 D6026 D6168 D6171

Summary:

Summary Statement of Deficiencies D3000 FACILITY ADMINISTRATION CFR(s): 493.1100 Each laboratory that performs nonwaived testing must meet the applicable requirements under 493.1101 through 493.1105, unless HHS approves a procedure that provides equivalent quality testing as specified in Appendix C of the State Operations Manual (CMS Pub. 7). (a) Reporting of SARS-CoV-2 test results During the Public Health Emergency, as defined in 400.200 of this chapter, each laboratory that performs a test that is intended to detect SARS-CoV-2 or to diagnose a possible case of COVID-19 (hereinafter referred to as a "SARS-CoV-2 test") must report SARS-CoV-2 test results to the Secretary in such form and manner, and at such timing and frequency, as the Secretary may prescribe. This CONDITION is not met as evidenced by: Based on surveyor's direct observation, laboratory documentation, and interview with the technical supervisor (TS), the laboratory failed to meet the requirements of this condition. The laboratory failed to provide a unidirectional workflow for molecular amplification procedures to minimize contamination of patient specimens, equipment, instruments, reagents, materials, and supplies. (Refer to D3005). D3005 FACILITIES CFR(s): 493.1101(a)(3) Molecular amplification procedures that are not contained in closed systems have a uni-directional workflow. This must include separate areas for specimen preparation, amplification and product detection, and, as applicable, reagent preparation. This STANDARD is not met as evidenced by: Based on surveyor's direct observation, manufacturers' instructions for use, laboratory Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- records, and interview with the technical supervisor (TS), the laboratory failed to maintain a uni-directional workflow for molecular amplification procedures to prevent potential cross-contamination in specimen processing, preparation, amplification, and detection for SARS-CoV-2 for two of two testing years (2022 and 2023). Findings Include: 1. Review of the "iAMP - COVID19-100" (iAMP) Detection Kit Instructions for Use" revealed the following: a. "Personnel must be familiar with the protocol and equipment/instruments used." b. "Maintain separate areas and dedicated equipment (e. g., pipettes, microcentrifuges) and supplies (e.g., microcentrifuge tubes, pipette tips, gowns and gloves) for assay reagent setup and handling of processed samples." c. "Workflow must always be from the clean area to the dirty area." 2. On 11/20/2023 at 11:35 a.m., direct observation of the TS demonstrating the testing procedures for the "iAMP - COVID19-100" (iAMP) assay revealed the following: a) the preparation of extraction buffer reagent, the transfer of patient samples to the patient testing plates, and the addition of positive and negative control samples to the patient testing plates all performed utilizing the same pipettes in one biosafety cabinet ("SterilGARD SN: 127773"); b) patient samples stored with new patient samples in one refrigerator / freezer ("Frigidaire EVENTEMP Serial No. 1K14671595"). 3. Review of laboratory records and lack of documentation revealed the laboratory failed to ensure one of two (TP 2) was qualified for high complexity molecular biology testing of SARS- CoV-2 in 2023. (Refer to D6171). 4. On 11/20/2023, at 11:35 a.m., an interview with the TS revealed, "Run samples go back into fridge, keep for two days; positives for three days in the freezer." D5787 TEST RECORDS CFR(s): 493.1283(a) The laboratory must maintain an information or record system that includes the following: (a)(1) The positive identification of the specimen. (a)(2) The date and time of specimen receipt into the laboratory. (a)(3) The condition and disposition of specimens that do not meet the laboratory's criteria for specimen acceptability. (a)(4) The records and dates of all specimen testing, including the identity of the personnel who performed the test(s). This STANDARD is not met as evidenced by: Based on review of laboratory records, lack of documentation, and interview with the technical supervisor (TS), the laboratory failed to identify the personnel performing high complexity molecular biology SARS-CoV-2 assay on five of five patient test runs from 11/2022 to date of survey 11/20/2023. Findings include: 1. Review of patient test run data for the SARS-CoV-2 assay ("iAMP - COVID19-100" (iAMP) found five of five instrument printouts from 11/2022 to date of survey 11/20/2023 failed to identify the testing personnel that performed the test run. a) Instrument printout A (Date: 11/29/2022): "Experiment Name: COVID19 TEST_20221129_193437 - admin" b) Instrument printout B (Date: 02/27/2023): "Experiment Name: COVID19 TEMPLATE_20230227_173853 - admin" c) Instrument printout C (Date: 08/21/2023): "Experiment Name: COVID19 TEMPLATE_20230821_160114 - admin" d) Instrument printout D (Date: 09/13 /2023): "Experiment Name: COVID19 TEMPLATE_20230913_164102 - admin" e) Instrument printout E (Date: 11/07/2023): "Experiment Name: COVID19 TEMPLATE_20231107_180835 - admin" 2. On 11/20/2023, at 1:33 p.m., an interview with the TS revealed, "No way to enter which testing personnel did the run, not listed on raw data, enter as admin only." -- 2 of 5 -- D6026 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(8) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(8) Ensure that reports of test results include pertinent information required for interpretation. This STANDARD is not met as evidenced by: Based on review of laboratory records, patient test reports and interview with the technical supervisor (TS), the laboratory failed to ensure 9 of 15 patient test reports reviewed for SARS-CoV-2, Influenza A, Influenza B and Respiratory Syncytial Virus (RSV) testing included pertinent information required for the interpretation of Influenza A, Influenza B and Respiratory Syncytial Virus (RSV). Findings include: 1. Review of the "Dupage County Diagnostics Molecular testing, Quality Control and Quality Assessment Policy" revealed the following information. "COVID policy: CLIA Self-Assessment ...3. Does the molecular diagnostics laboratory provide ... Availability of consultation regarding test selection, results interpretation, and implication of results?" 2. Review of patient test reports and lack of documentation revealed 9 of 15 SARS-CoV-2, Influenza A, Influenza B and RSV final test reports failed to include pertinent information required for the interpretation of Influenza A, Influenza B and RSV. a) MRN: 102696 DATE: 03/06/2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV b) MRN: 103327 DATE: 03/11 /2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV c) MRN: 104363 DATE: 03/18/2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV d) MRN: 109206 DATE: 05/01/2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV e) MRN: 110023 DATE: 05/06 /2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV f) MRN: 110742 DATE: 05/10/2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV g) MRN: 116471 DATE: 09/03/2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV h) MRN: 117270 DATE: 09/11 /2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV i) MRN: 118776 DATE: 09/24/2024 TESTS REPORTED: SARS-CoV-2, Influenza A, Influenza B and RSV 3. On 10/07/2024, at 4:27 p.m., the TS confirmed the results of the final test results documented in Finding 1. D6168 TESTING PERSONNEL CFR(s): 493.1487 The laboratory has a sufficient number of individuals who meet the qualification requirements of 493.1489 of this subpart to perform the functions specified in 493. 1495 of this subpart for the volume and complexity of testing performed. This CONDITION is not met as evidenced by: Based on review of laboratory records, lack of documentation, Laboratory Personnel Report (CMS-209), and interview with the technical supervisor (TS), the laboratory failed to retain education transcripts to qualify one of two testing personnel (TP 2) for high complexity SARS-CoV-2 testing from 01/16/2023 to date of survey 11/20/2023 affecting 7000 tests performed. (Refer to D6171). -- 3 of 5 -- D6171 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1489(b) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located or have earned a doctoral, master's or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution; (b)(2)(i) Have earned an associate degree in a laboratory science, or medical laboratory technology from an accredited institution or-- (b)(2)(ii) Have education and training equivalent to that specified in paragraph (b)(2)(i) of this section that includes-- (b)(2)(ii)(A) At least 60 semester hours, or equivalent, from an accredited institution that, at a minimum, include either-- (b)(2)(ii)(A)(1) 24 semester hours of medical laboratory technology courses; or (b)(2)(ii)(A)(2) 24 semester hours of science courses that include-- (b)(2) (ii)(A)(2)(i) Six semester hours of chemistry; (b)(2)(ii)(A)(2)(ii) Six semester hours of biology; and (b)(2)(ii)(A)(2)(iii) Twelve semester hours of chemistry, biology, or medical laboratory technology in any combination; and (b)(2)(ii)(B) Have laboratory training that includes either of the following: (b)(2)(ii)(B)(1) Completion of a clinical laboratory training program approved or accredited by the ABHES, the CAHEA, or other organization approved by HHS. (This training may be included in the 60 semester hours listed in paragraph (b)(2)(ii)(A) of this section.) (b)(2)(ii)(B)(2) At least 3 months documented laboratory training in each specialty in which the individual performs high complexity testing. (b)(3) Have previously qualified or could have qualified as a technologist under 493.1491 on or before February 28, 1992; (b) (4) On or before April 24, 1995 be a high school graduate or equivalent and have either-- (b)(4)(i) Graduated from a medical laboratory or clinical laboratory training program approved or accredited by ABHES, CAHEA, or other organization approved by HHS; or (b)(4)(ii) Successfully completed an official U.S. military medical laboratory procedures training course of at least 50 weeks duration and have held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); (b)(5)(i) Until September 1, 1997-- (b)(5)(i)(A) Have earned a high school diploma or equivalent; and (b)(5)(i)(B) Have documentation of training appropriate for the testing performed before analyzing patient specimens. Such training must ensure that the individual has-- (b)(5)(i)(B)(1) The skills required for proper specimen collection, including patient preparation, if applicable, labeling, handling, preservation or fixation, processing or preparation, transportation and storage of specimens; (b)(5)(i)(B)(2) The skills required for implementing all standard laboratory procedures; (b)(5)(i)(B)(3) The skills required for performing each test method and for proper instrument use; (b)(5)(i)(B)(4) The skills required for performing preventive maintenance, troubleshooting, and calibration procedures related to each test performed; (b)(5)(i)(B)(5) A working knowledge of reagent stability and storage; (b)(5)(i)(B)(6) The skills required to implement the quality control policies and procedures of the laboratory; (b)(5)(i)(B)(7) An awareness of the factors that influence test results; and (b)(5)(i)(B)(8) The skills required to assess and verify the validity of patient test results through the evaluation of quality control values before reporting patient test results; and (b)(5)(i)(B)(8)(ii) As of September 1, 1997, be qualified under 493.1489(b)(1), (b)(2), or (b)(4), except for those individuals qualified under paragraph (b)(5)(i) of this section who were performing high complexity testing on or before April 24, 1995; (b)(6) For blood gas analysis-- (b)(6) (i) Be qualified under 493.1489(b)(1), (b)(2), (b)(3), (b)(4), or (b)(5); (b)(6)(ii) Have earned a bachelor's degree in respiratory therapy or cardiovascular technology from an accredited institution; or (b)(6)(iii) Have earned an associate degree related to pulmonary function from an accredited institution; or (b)(7) For histopathology, meet -- 4 of 5 -- the qualifications of 493.1449 (b) or (l) to perform tissue examinations. This STANDARD is not met as evidenced by: Based on review of laboratory records, lack of documentation, Laboratory Personnel Report (CMS-209), and interview with technical supervisor (TS), the laboratory failed to ensure one of two testing personnel were qualified for high complexity molecular biology testing of SARS- CoV-2 in 2023. Affecting 7000 test performed. Findings Include: 1. Review of the CMS-209 (11/20/2023) and lack of documentation revealed the laboratory failed to retain education transcripts to qualify one of two testing personnel (TP 2) for high complexity SARS-CoV-2 testing from 01/16/2023 to date of survey 11/20/2023 affecting 7000 tests performed. 2. On 11/20/2023, at 2:39 p.m., the TS confirmed the above finding. -- 5 of 5 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access