East Tn Hematology & Oncology

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 44D0896759
Address 1021 Coolidge St Ste 3, Greeneville, TN, 37743
City Greeneville
State TN
Zip Code37743
Phone(423) 787-7080

Citation History (2 surveys)

Survey - May 14, 2019

Survey Type: Standard

Survey Event ID: EO2Q11

Deficiency Tags: D5291 D5429 D5439

Summary:

Summary Statement of Deficiencies D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. This STANDARD is not met as evidenced by: ==================================== Based on review of Quality Assurance (QA) Plan, lack of QA documentation for 2018 and 2019 and upon interview with the primary testing person and Laboratory Supervisor, determined the laboratory failed to follow QA plan for 2018 and 2019. The findings include: 1. Review of QA Plan states that monitors will be: a. Monthly Chart Audits b. Proficiency Testing Tracking Sheet c. Mainenance, Calibration and QC Tracking Sheet d. Communications, Complaints, Problems and Personnel Tracking Sheet 2. Lack of QA documentation for 2018 and 2019. 3. Interview with the primary testing person and Laboratory Supervisor at approximately 12:30 p.m. May 14, 2019 confirmed the laboratory had not been performing Quality Assurance Monitors for the last 2 years. ===================================== D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- ==================================== Based on review of CBC (Complete Blood Count) instrument maintenance requirements, review of maintenance logs for 2019 and interview with the primary testing person and laboratory supervisor, determined the laboratory failed to document CBC instrument maintenance since April 15th, 2019. The findings include: 1. Review of the CBC instrument maintenance requires daily, monthly and PRN (as needed) maintenance to be performed (see maintenance log attachment). 2. Review of maintenance logs for 2019 revealed maintenance had not been documented since April 15th, 2019. 3. Interview with primary testing person and laboratory supervisor at approximately 12: 30 p.m. May 14, 2019 confirmed that maintenance for the CBC instrument had not been documented since April 15th, 2019. ===================================== D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: ==================================== Based on review of Calibration Verification for the CBC instrument to be done every 6 months per procedure, lack of 6 month calibration verification after 8/6/18 and interview with the primary testing person, determined the laboratory failed to follow their procedure for calibration verificaton every 6 months. The findings include: 1. Review of the Calibration Verification procedure for the CBC instrument states to perform every 6 months. 2. Lack of 6 month calibration verification after 8/6/18. 3. Interview with the primary testing person at approximately 12:00 p.m. May 14, 2019 confirmed the last calibration verification for the CBC instrument was performed 9 months previously on 8/6/18, thus failing to follow procedure for performing every 6 months. ===================================== -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 14, 2019

Survey Type: Special

Survey Event ID: E5IW11

Deficiency Tags: D2016 D2130

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: =================================== Hematology: The laboratory failed to maintain satisfactory participation in two out of three events for the Automated White Blood Cell (WBC) Differential, resulting in the first unsuccessful proficiency testing (PT) occurrence for the automated WBC Differential analyte (Refer to D2130). ==================================== D2130 HEMATOLOGY CFR(s): 493.851(f) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: ==================================== Based on a desk review of the CMS CASPER Report 0155D and the laboratory's 2018 Proficiency Testing (PT) records, the laboratory failed to maintain satisfactory performance for Hematology in the 1st and 3rd events of 2018, resulting in the first unsuccessful occurrence. The findings include: 1. Review of the CMS 0155D report revealed the 2018 Hematology score for event one was 60% and for event three was 0%. 2. Review of the laboratory's 2018 PT records revealed event one had unacceptable scores for Red Blood Cells (RBC's) of 60%; Hematocrit (Hct) of 40%; Hemoglobin (Hgb) of 40%; White Blood Cells (WBC's) of 60% and Platelets (Plt's) of 60%. 3. Review of the laboratory's 2018 PT records revealed event three had unacceptable scores of 0% for RBC's; Hct; Hgb; WBC's and Plt's resulting in the first unsuccessful PT occurrence for Hematology. ==================================== -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access