Eastman Pediatric Clinic

CLIA Laboratory Citation Details

3
Total Citations
10
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 11D0685804
Address 1223 Plaza Ave, Eastman, GA, 31023
City Eastman
State GA
Zip Code31023
Phone478 374-3814
Lab DirectorJOHN MD

Citation History (3 surveys)

Survey - February 22, 2022

Survey Type: Special

Survey Event ID: W7VY11

Deficiency Tags: D0000 D2130 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D0000 A proficiency testing desk review was completed on February 22, 2022. At the time of the review, the laboratory was not in compliance with the Clinical Laboratory Improvement Amendments of 1988, 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two of three consecutive events (3rd event of 2020 and 1st event of Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- 2021), resulting in the first unsuccessful occurrence for Hematology # 760 : including red blood cell count (RBC) #775 Findings include: Refer to D 2130 D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory failed to maintain satisfactory performance in two of three consecutive events (3rd event of 2020 and 1st event 2021), resulting in the first unsuccessful occurrence for red blood cell (RBC) # 775. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte #775 RBC on Event 3 of 2020 with a score of 40% and & Event 1 of 2021 with a score of 60%. 2. Desk review of the laboratory's proficiency testing reports from American Academy of Family Physicians (AAFP)confirmed the laboratory failed RBC on Event 3 of 2020 and 1 of 2021 resulting in the first unsuccessful performance.. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two of three consecutive events ( 3rd event of 2020 and 1st event of 2021), resulting in the first unsuccessful occurrence for red blood cell (RBC), analyte # 775 Findings include: Refer to D 6016 D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on proficiency testing desk review using the Centers for Medicare and Medicaid (CMS) Casper Reports 155 and 153 and review of the laboratory's -- 2 of 3 -- proficiency testing (PT) reports, the laboratory director failed to ensure the laboratory maintained satisfactory performance in two of three consecutive events (3rd event 2020 and 1st event of 2021) resulting in the first unsuccessful occurrence for red blood cell (RBC), analyte # 775. Findings include: 1. Desk review of Casper Reports 153 and 155 disclosed the laboratory failed analyte # 775 , RBC on event 3 of 2020 with a score of 40% and event 1 of 2021 with a score of 60%. 2. Desk review of the laboratory's proficiency testing reports from American Proficiency Institute (API) confirmed the laboratory failed RBC on Events 3 of 20202 and 1 of 2021, resulting in the first unsuccessful performance. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 25, 2021

Survey Type: Standard

Survey Event ID: 8BZN11

Deficiency Tags: D5211 D0000 D6018

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) Recertification survey was completed on February 25, 2021. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on the review of the American Academy of Family Physicians (AAFP) Proficiency Testing (PT) provider, the Laboratory failed to ensure that all PT reports received are reviewed by the appropriate staff to evaluate the laboratory's performance and to identify any problems that require

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 15, 2018

Survey Type: Standard

Survey Event ID: FP4R11

Deficiency Tags: D0000 D5805

Summary:

Summary Statement of Deficiencies D0000 A Clinical Laboratory Improvement Amendments (CLIA) recertification survey was completed on August,15 2018. The laboratory was not in compliance with applicable CLIA requirements found at 42 CFR 493.1 through 42 CFR 493.1780. The following deficiencies were cited: D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on patient chart review and reports for 2017 and 2018, and staff interview, the laboratory failed to provide the units of measure and reference ranges for results from the Abbott Cell-Dyn Emerald hematology analyger. Findings: 1. Review of patient charts and patient reports for 2017 and 2018, the reports did not have the units of measure and the reference range for each analyte of the Complete Blood Count, from the Abbott Cell-Dyn Emerald. 2. Interview with staff #3, and the Laboratory Director, on August 15, 2018 at approximately 1:30 pm in the nurses station, confirmed that the units of measure and the reference ranges for each analyte were not on the reports pulled from 2017 and 2018, from the Abbott Cell-Dyn Emerald. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access