Encompass Health Rehabilitation Hospital Of

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 03D0885959
Address 9630 E Shea Blvd, Scottsdale, AZ, 85260
City Scottsdale
State AZ
Zip Code85260
Phone(480) 551-5400

Citation History (2 surveys)

Survey - August 10, 2021

Survey Type: Standard

Survey Event ID: JE4511

Deficiency Tags: D5445 D6046 D5439 D6020

Summary:

Summary Statement of Deficiencies D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on lack of calibration verification documentation for blood gas testing and Chem8+ testing and interview with the testing personnel, the laboratory failed to perform and document calibration verification procedures as required. Findings include: 1. The laboratory performs Arterial Blood Gas (ABG) testing and Chem8+ testing on the I-Stat analyzer, with an approximate annual test volume of 900. 2. No documentation was presented for review to indicate the laboratory performed a Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- calibration verification for ABG testing at least once every six months during 2019, 2020 and in 2021 through the date of the survey conducted on 8/10/21, including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results. 3. No documentation was presented for review to indicate the laboratory performed a calibration verification for Chem8+ testing at least once every six months during 2020 and in 2021 through the date of the survey conducted on 8/10/21, including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results. 4. The facility personnel acknowledged that a calibration verification was not performed every 6 months as indicated above on the I-stat analyzer as required for ABG and Chem8+ testing. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on lack of Quality Control (QC) documentation and interview with the facility personnel, the laboratory failed to perform and document control procedures using the number and frequency as required for testing performed in the specialties of Hematology and Chemistry. Findings include: 1. The laboratory began using the Chem8+ test cartridge performed on the i-Stat in January 2020. The Chem8+ panel includes the following analytes: Sodium, Potassium, Chloride, Ionized Calcium, Total CO2, Glucose, BUN, Creatinine, Hematocrit and Hemoglobin. The laboratory's approximate annual test volume for the Chem8+ test is 248 tests. 2. On the date of the survey, August 10, 2021, it was the policy of the laboratory to test 3 levels of QC material at the beginning of each month. 3. No daily QC documentation for Chem8+ testing was provided for review during the survey from the time period of January 1, 2020 through August 10, 2021, to indicate the laboratory performed at least two levels of control material of different concentrations each day of patient testing, as required. The laboratory had not established an Individualized Quality Control Plan (IQCP) for this test. 4. The facility personnel confirmed the laboratory did not perform and document external controls each day of patient testing as required since patient testing began on 1/01/2020. D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and -- 2 of 3 -- maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on lack of Quality Control documentation for review for Chem8+ testing performed on the I-stat analyzer, the laboratory director failed to ensure that the quality control program is established to assure the quality of laboratory services provided. See D5445 for findings. D6046 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8) (b) The technical consultant is responsible for-- (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: Based on review of testing personnel competency assessments for 2020 pertaining to blood gas testing and interview with the facility personnel, the technical consultant failed to indicate by signature and date that any of the assessments performed on six out of six testing personnel were evaluated by the technical consultant indicated on the CMS-209 form (Laboratory Personnel Report). Findings include: 1. The competency assessment evaluations were being signed off by one of the testing personnel indicated on the CMS-209 form with no indication of competency assessment being performed by the technical consultant for moderate complexity testing under the specialty of Chemistry. 2. The annual competency assessment form from 2020 presented for review for one testing personnel failed to include the signature of the individual who performed the competency evaluation. The form was only signed by the testing personnel who was being evaluated and dated 2/06/2020. 3. The facility personnel acknowledged that the competency assessments were being performed by the testing personnel and not the Technical Consultant. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 24, 2019

Survey Type: Standard

Survey Event ID: 324B11

Deficiency Tags: D2009 D6054 D5787 D6065

Summary:

Summary Statement of Deficiencies D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on review of proficiency testing (PT) records from 2018 and 2019 and interview with the facility personnel, the laboratory director and testing personnel failed to sign the PT attestation statement for the 2nd event of 2019 for Chemistry for Blood Gas testing. Findings include: 1. The PT attestation statement presented for review for the second event of 2019 for Chemistry lacked the director's signature and the signature of the testing personnel. 5. The facility personnel confirmed that the PT attestation statement indicated above was not signed by the laboratory director or the testing personnel. D5787 TEST RECORDS CFR(s): 493.1283(a) The laboratory must maintain an information or record system that includes the following: (a)(1) The positive identification of the specimen. (a)(2) The date and time of specimen receipt into the laboratory. (a)(3) The condition and disposition of specimens that do not meet the laboratory's criteria for specimen acceptability. (a)(4) The records and dates of all specimen testing, including the identity of the personnel who performed the test(s). This STANDARD is not met as evidenced by: Based on review of i-Stat Blood Gas test records and interview with the facility Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- personnel, the laboratory failed to have a system in place to positively identify the individual that was associated with the specific operator ID indicated on each test result strip. Findings include: 1. The i-Stat Blood Gas test result strips indicate different operator ID numbers depending on which testing personnel performed the test. 2. There was no reference sheet or key that indicated each individual testing personnel's name and their specific operator ID that was associated with their name. 3. Each test result sheet had a signature of the testing personnel, but there was no way to verify that the operator ID indicated on the test result strip belonged to the individual that signed the test result sheet. 4. The facility personnel acknowledged that a operator ID reference sheet or key did not exist. D6054 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least annually, after the first year. This STANDARD is not met as evidenced by: Based on lack of competency evaluation documentation for review and interview with the facility personnel, the technical consultant failed to provide verification documentation of the performance of individuals responsible for moderate complexity testing at least annually. Findings include: 1. No annual competency evaluation verification documentation for Blood Gas testing was presented for 2 out of 4 testing personnel for 2018. 2. The facility personnel acknowledged that the annual competency evaluations for two testing personnel were not provided for review at the time of the survey. D6065 TESTING PERSONNEL QUALIFICATIONS CFR(s): 493.1423(b)(1)(2)(3)(4)(i) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located or have earned a doctoral, master's, or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution; or (b)(2) Have earned an associate degree in a chemical, physical or biological science or medical laboratory technology from an accredited institution; or (b)(3) Be a high school graduate or equivalent and have successfully completed an official military medical laboratory procedures course of at least 50 weeks duration and have held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); or (b)(4)(i) Have earned a high school diploma or equivalent; and This STANDARD is not met as evidenced by: Based on lack of verification of educational requirements and interview with the laboratory personnel, the laboratory failed to provide required documentation of testing personnel qualifications for one out of four testing personnel. Findings include: 1. No documentation of education qualifications were presented for review for one out of four testing personnel who performs moderate complexity patient -- 2 of 3 -- testing under the sub-specialty of Routine Chemistry. 2. The facility personnel confirmed that the education documentation for the testing personnel indicated above was not available at the time of the survey. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access