Freeman Physician Group Of Pittsburg

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 17D2066674
Address 1201 East Centennial, Pittsburg, KS, 66762
City Pittsburg
State KS
Zip Code66762
Phone(620) 231-0204

Citation History (1 survey)

Survey - July 18, 2022

Survey Type: Standard

Survey Event ID: EN9R11

Deficiency Tags: D3017 D5421 D5421

Summary:

Summary Statement of Deficiencies D3017 REQUIREMENTS FOR TRANSFUSION SERVICES CFR(s): 493.1103(a) Arrangement for services. The facility must have a transfusion service agreement reviewed and approved by the responsible party(ies) that govern the procurement, transfer, and availability of blood and blood products. This STANDARD is not met as evidenced by: Based on documentation of transfusion services provided on site, the lack of a transfusion service agreement, and interview, the laboratory failed to have a transfusion service agreement reviewed and approved by the responsible parties that govern the procurement, transfer, and availability of blood and blood products. Findings: 1. The surveyor noted that a blood bank refrigerator was in the lab. The surveyor asked the general supervisor (GS) if blood and/or blood products were transfused at this site. The GS confirmed that blood and blood products were transfused, but no immunohematology testing was performed at this site. 2. Request was made to see the transfusion services agreement with the blood product service provider. The document provided was a procedure from another CLIA laboratory (lab B) which provided immunohematology services, blood and blood products to this site. The lab B document did not list any information as to an agreement with this laboratory for immunohematology services. 3. Interview with the GS on 7/18/22 at 3: 15 p.m. confirmed, the laboratory failed to have a transfusion service agreement reviewed and approved by the responsible parties that govern the procurement, transfer, and availability of blood and blood products. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of performance verification documentation for the Sysmex XN1000 hematology analyzer, non-waived test lists, and interview, the laboratory failed to verify the reference intervals (normal values) were appropriate for the laboratory's patient population prior to performing patient testing. Findings: 1. Review of the verification documentation of the Sysmex XN1000 hematology analyzer, S/N N81132, for the analytes: White Blood Cell Differential, Red Blood Cell Count, Hemoglobin, Hematocrit, White Blood Cell Count, and Platelet testing showed no verification of normal values at time of survey. Document listed patient testing began in 1/17/22. 2. Review of the KS-CLIA-PS02 non-waived test lists showed the XN1000 annual test volume was 17,423 patient test results. 3. Interview with the GS on 7/18/22 at 2:10 p.m. confirmed, the laboratory failed to verify the reference intervals (normal values) were appropriate for the laboratory's patient population prior to performing patient testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access