Froedtert Community Hospital - Pewaukee

CLIA Laboratory Citation Details

3
Total Citations
16
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 52D2193939
Address 209 Pewaukee Road, Pewaukee, WI, 53072
City Pewaukee
State WI
Zip Code53072
Phone(262) 956-6150

Citation History (3 surveys)

Survey - January 7, 2025

Survey Type: Standard

Survey Event ID: II2711

Deficiency Tags: D5415 D5415

Summary:

Summary Statement of Deficiencies D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) (c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (c)(1) Identity and when significant, titer, strength or concentration. (c)(2) Storage requirements. (c)(3) Preparation and expiration dates. (c)(4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on surveyor observation of the Abbott I-Stat reagent cartridges and interview with a technical consultant, staff A, testing personnel did not label nineteen of nineteen I-Stat Chem 8+ cartridges with the shortened room temperature expiration date. Findings include: 1. Observation of the Abbott I-Stat Chem 8+ cartridges box on January 7, 2025, at 12::13 PM revealed nineteen cartridges, Lot# H24349A, original expiration date of June 12, 2025, were being stored at room temperature. Further observation of the cartridge box showed a line for the new expiration date after being placed at room temperature and the new expiration date was not labeled on the cartridges or the box. 2. Interview with staff A on January 7, 2025, at 12:15 PM, confirmed the expiration date of the cartridges changed when the cartridges were stored at room temperature and testing personnel did not label the Abbott I-Stat Chem 8+ cartridges with the shortened expiration date after being placed at room temperature. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 14, 2023

Survey Type: Standard

Survey Event ID: ZLAD11

Deficiency Tags: D5215 D5409 D5545 D5787 D6019 D6072 D5215 D5409 D5545 D5787 D6019 D6072

Summary:

Summary Statement of Deficiencies D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on surveyor review of proficiency testing (PT) records from the 2022 Chemistry Core events and interview with the technical consultant, the laboratory did not document review of D-dimer results that the PT provider did not grade in two of two events performed with the Pathfast analyzer. Findings include: 1. Review of API (American Proficiency Institute) PT records for the Chemistry core events in 2022 showed the laboratory used the Pathfast analyzer for D-dimer testing in the second and third events. The records showed the PT provider did not grade the D-dimer results for samples CM-08 and CM-09 in the second event and samples CM-11 and CM-12 in the third event. The laboratory reported the D-dimer concentration for each of these samples as >5 ugFEU/mL (greater than 5 microgram Fibrinogen Equivalent Units / milliliter). The records showed no documented review of the ungraded results. 2. Interview with the technical consultant on March 14, 2023 at 10:50 AM confirmed the laboratory did not document the review of the unscored D-dimer PT results. D5409 PROCEDURE MANUAL CFR(s): 493.1251(e) The laboratory must maintain a copy of each procedure with the dates of initial use and discontinuance as described in 493.1105(a)(2). Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- This STANDARD is not met as evidenced by: Based on surveyor review of laboratory procedures and interview with the technical consultant, the laboratory did not maintain one of one discontinued procedure with the date the test was discontinued and one of one new procedure with the initiation date of testing at this laboratory. Findings include: 1. Interview with the technical consultant on March 14, 2023 at 12:30 PM confirmed the laboratory's use of the Triage test system was discontinued on April 11, 2022 and replaced with the Fastpath test system. 2. Review of the printed procedure manual showed no procedure for the Triage test system. The procedure for the Fastpath system showed the origination date for the procedure was January 1, 2022. The procedure did not include an initiation date for use in this laboratory. 3. Review of the electronic version of the Triage test system procedure showed no date of discontinuation for the test system at this laboratory. 4. Further interview with the technical consultant on March 14, 2023 at 12: 30 PM confirmed the laboratory had removed the Triage procedure from the manual without documenting the date of discontinuation and confirmed the Fastpath procedure did not show the initiation date for testing at this laboratory. D5545 HEMATOLOGY CFR(s): 493.1269(b)(d) (b) For all nonmanual coagulation test systems, the laboratory must include two levels of control material each 8 hours of operation and each time a reagent is changed. (d) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on surveyor review of laboratory records and procedures, and interview with the laboratory director, the laboratory has not performed two levels of quality control (QC) each eight hours of patient testing in twelve of twelve months since starting D- dimer testing on the Fastpath analyzer in April 2022. Findings include: 1. Review of Pathfast worksheets showed QC testing was performed once per day for the three tests performed on the test system. 2. Review of the 'Pathfast Instrument Testing (Troponin I, NT-pro-BNP, D-dimer)' procedure showed the procedure required two levels of external QC daily for D-dimer testing. The procedure did not include instructions to perform QC testing every eight hours of patient testing. 3. Interview with the laboratory director on March 14, 2023 at 11:50 AM confirmed the laboratory did not perform QC testing each eight hours of patient testing on the Fastpath D-dimer test since starting testing in April 2022. D5787 TEST RECORDS CFR(s): 493.1283(a) The laboratory must maintain an information or record system that includes the following: (a)(1) The positive identification of the specimen. (a)(2) The date and time of specimen receipt into the laboratory. (a)(3) The condition and disposition of specimens that do not meet the laboratory's criteria for specimen acceptability. (a)(4) The records and dates of all specimen testing, including the identity of the personnel who performed the test(s). This STANDARD is not met as evidenced by: -- 2 of 4 -- Based on surveyor review of test records and interview with the laboratory director, the laboratory did not maintain a record system that identified which testing person performed each complete blood count (CBC) analysis on the Sysmex XN-330 hematology analyzer in 2022 and 2023. Findings include: 1. Review of test records showed no paper records of CBC tests performed on the Sysmex XN-330 hematology analyzer. Review of electronic records in the medical record showed no record of which person performed the CBC tests on the Sysmex XN-330. The laboratory estimated they performed 2583 CBCs annually. 2. Interview with the laboratory director on March 14, 2023 at 1:25 PM confirmed the laboratory did not maintain a record system that included the identity of the testing personnel who performed CBC testing on the Sysmex XN-330 analyzer. D6019 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(iv) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(iv) Ensure that an approved

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 21, 2021

Survey Type: Standard

Survey Event ID: PHVZ11

Deficiency Tags: D6006 D6006

Summary:

Summary Statement of Deficiencies D6006 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(d) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (d) Each individual may direct no more than five laboratories. This STANDARD is not met as evidenced by: Based on surveyor review of the Clinical Laboratory Improvement Amendments (CLIA) Search Results List from the federal ASPEN database for laboratories directed by the laboratory director for Froedtert Community Hospital-Pewaukee CLIA laboratory, email from the manager of accreditation and safety, staff A, and interview with the technical consultant, the director is directing six non-waived laboratories. Finding include: 1. Review of the CLIA Search Results List for laboratories directed by the laboratory director for Froedtert Community Hospital-Pewaukee queried from the federal ASPEN database on September 7, 2021 showed this laboratory director is directing the following laboratories: CLIA number/Name/Certificate Type 52D2140776/Froedtert & MCW Drexel Town Square Laboratory/Certificate of Compliance 52D2115357/Froedtert Community Hospital-New Berlin/Certificate of Compliance 52D2193939/Froedtert Community Hospital-Pewaukee/Certificate of Registration 52D0715725/Froedtert Memorial Lutheran Hospital/Certificate of Accreditation 52D0720169/Medical College of Wisconsin Pathology/Certificate of Accreditation 52D0391886/Wisconsin Diagnostic Laboratories, LLC/Certificate of Accreditation 2. Email from staff A on September 19, 2021 at 6:56 PM confirmed the laboratory director for Froedtert Community Hospital-Pewaukee is directing six non- waived laboratories. 3. Interview with the technical consultant on September 21, 2021 at 10:10 AM confirmed the laboratory director for Froedtert Community Hospital- Pewaukee was directing six non-waived laboratories. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access