Galen East Laboratory

CLIA Laboratory Citation Details

2
Total Citations
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 44D2020576
Address 1651 Gunbarrel Rd, Suite 102-A, Chattanooga, TN, 37421
City Chattanooga
State TN
Zip Code37421
Phone423 468-1543
Lab DirectorTHOMAS BRIEN

Citation History (2 surveys)

Survey - July 30, 2025

Survey Type: Standard

Survey Event ID: NVGX11

Deficiency Tags: D5417

Summary:

Summary Statement of Deficiencies D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) (d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on observation of the laboratory and staff interviews, the laboratory failed to ensure that it did not use nine of nine lots of tissue marking dyes beyond their expiration dates in histopathology patient testing in 2024 and 2025. The findings include: 1. Observation of the laboratory on 07/30/2025 at 09:20 a.m. revealed two grossing stations used for gross examination of tissue specimens. Both stations contained marking dyes used for marking tissue. The following dyes had expired: Grossing station 1: Color Lot No Exp Date Orange 22349 12.31.24 Green 23062 03.31.25 Yellow Illegible Illegible Red 22203 10.21.24 Grossing station 2: Color Lot No Exp Date Green 22322 11.30.24 Red 22306 11.30.24 Yellow 22308 11.30.24 Orange 22214 08.31.24 Violet 22276 10.31.24 The histology technician discarded the dyes on the day of the survey. 3. An interview with the histology technician on 07/30 /2025 at 9:20 a.m. confirmed that the laboratory used the observed tissue marking dyes for patient testing after expiration. . Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 13, 2023

Survey Type: Standard

Survey Event ID: X7ER11

Deficiency Tags: D5413

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of the manufacturer's operating manuals, environmental records request, and interview with the lead histotech, the laboratory failed to monitor room humidity for the Leica EG 1150 H Paraffin Embedding Station, Leica EG 1150 C Cold Plate, and Sakura Tissue-Tek SCA Coverslipper in 2021, 2022, and 2023. The findings include: 1. Observation of the laboratory on April 13, 2023 at 9:30 a.m. revealed the Leica EG 1150 H Paraffin Embedding Station (serial #038837689), Leica EG 1150 C Cold Plate (serial #038838038), and Sakura Tissue-Tek SCA Coverslipper (serial #90060107) in use for processing tissues removed during surgical procedures in preparation for histopathology procedures. 2. Review of the manufacturer's operating manuals revealed the following: - Leica EG 1150 H Paraffin Embedding Station environmental conditions require a maximum relative humidity of 60%. - Leica EG 1150 C Cold Plate environmental conditions require a maximum relative humidity of 80%. - Sakura Tissue-Tek SCA Coverslipper environmental conditions require an operating humidity range 30% - 70%. 3. Request of environmental records revealed no records for monitoring room humidity available for surveyor review. 4. Interview on April 13, 2023, at approximately 11:45 a.m. with the lead histotech confirmed the laboratory failed to monitor room humidity for the use of the Leica EG 1150 H Paraffin Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Embedding Station, Leica EG 1150 C Cold Plate, and Sakura Tissue-Tek SCA Coverslipper in 2021, 2022, and 2023. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access