Gbmc Main Laboratory

CLIA Laboratory Citation Details

1
Total Citation
10
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 21D0216885
Address 6701 North Charles Street, Baltimore, MD, 21212
City Baltimore
State MD
Zip Code21212
Phone(443) 849-2000

Citation History (1 survey)

Survey - April 5, 2024

Survey Type: Standard

Survey Event ID: 74FV11

Deficiency Tags: D2011 D5403 D5417 D5429 D5783 D2011 D5403 D5417 D5429 D5783

Summary:

Summary Statement of Deficiencies D2011 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(3) Laboratories that perform tests on proficiency testing samples must not engage in any inter-laboratory communications pertaining to the results of proficiency testing sample (s) until after the date by which the laboratory must report proficiency testing results to the program for the testing event in which the samples were sent. Laboratories with multiple testing sites or separate locations must not participate in any communications or discussions across sites/locations concerning proficiency testing sample results until after the date by which the laboratory must report proficiency testing results to the program. This STANDARD is not met as evidenced by: Based on review of proficiency testing (PT) records and interview with the histology and immunohistochemistry pathologist, the laboratory did not ensure that PT results were independently reviewed by the pathologists until after the PT results were submitted to the PT provider. Findings: 1. Records for the ISH-A 2023 PT event included a worksheet showing that six pathologists reviewed the PT samples and recorded their results. The worksheets did not include the date each pathologist reviewed the PT samples. 2. During the survey on 04/04/2024 at 3:20 PM, the histology and immunohistochemistry pathologist confirmed that the six pathologists reviewed the PT results independently prior to submitting the results to the PT provider. D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access