Gopal Reddy Gade Md

CLIA Laboratory Citation Details

3
Total Citations
16
Total Deficiencyies
14
Unique D-Tags
CMS Certification Number 05D0713674
Address 6183 N Fresno St Ste 105, Fresno, CA, 93710
City Fresno
State CA
Zip Code93710
Phone(559) 261-0794

Citation History (3 surveys)

Survey - August 18, 2021

Survey Type: Special

Survey Event ID: CGW311

Deficiency Tags: D2028 D6089 D2016 D6076

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events in the specialty of Bacteriology constituting unsuccessful PT performances. (See D2028) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2028 BACTERIOLOGY CFR(s): 493.823(e) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT events for the analyte, Bacteriology, resulting in an non-initial unsuccessful performances. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for Bacteriology, as follows: 2020 2020 2020 Q1 Q2 Q3 Bacteriology 0% 0% 0% Q1 = First Testing Event Q2 = Second Testing Event Q3 = Third Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an non-initial unsuccessful performances for Bacteriology. D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6076) D6089 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(4)(i) The laboratory director must ensure the proficiency testing samples are tested as required under subpart H of this part. This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the analyte, Bacteriology, the laboratory repeatedly failed to achieve satisfactory performance for the same analyte or test in two out of three consecutive testing events, resulting in unsuccessful PT performances. (See D2016 and D2028) -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 10, 2020

Survey Type: Standard

Survey Event ID: 3B6S11

Deficiency Tags: D5200 D5217 D6017 D6053 D5203 D5891 D6030 D6054

Summary:

Summary Statement of Deficiencies D5200 GENERAL LABORATORY SYSTEMS CFR(s): 493.1230 Each laboratory that performs nonwaived testing must meet the applicable general laboratory systems requirements in 493.1231 through 493.1236, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the general laboratory systems and correct identified problems specified in 493.1239 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition for General Laboratory Systems was not met. The laboratory failed to follow the written laboratory policy and procedure to assess employee competency (See D6030); failed to evaluate and document the performance of an individual(s) responsible for moderate complexity testing at least semiannually during the first year the individual (s) tests patients, and thereafter, evaluations must be performed at least annually (See D6053, D6054). The laboratory failed to establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the general laboratory systems (See D5891). D5203 SPECIMEN IDENTIFICATION AND INTEGRITY CFR(s): 493.1232 The laboratory must establish and follow written policies and procedures that ensure positive identification and optimum integrity of a patient's specimen from the time of collection or receipt of the specimen through completion of testing and reporting of results. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- This STANDARD is not met as evidenced by: Based on review of patient testing log, patient final testing reports [electronic medical records (EMR)], and interview with the laboratory personnel, it was determined that from 03/26/2019 through 07/10/2020 for one (1) out of ten (10) random patient testing records reviewed, the laboratory failed to follow written policies and procedures for specimen collection, through completion of testing and reporting results. The findings included: 1. Review of the AFFIRM VPIII Microbial Identification (AFFIRM) patient test logs on 09/10/2020 at 11 a.m. (survey date) and patient medical record (MR), it was found that patient test results were not reported (scanned) in the patient's medical record. On 07/10/202 review of the AFFIRM testing log showed patient ID M M receipt time of 9:54 [Trichomonas vaginalis (-), Gardnerella vaginalis (+) and Candida sp. (-)] were resulted in the patient test log, but could not be retrieved in the patient's electronic medical record (EMR). 2. On 09/10//2020 at 12:30 a.m. (survey date), the laboratory personnel affirmed that the patient testing results could not retrieve in the patient medical records. 3. Based on the laboratory's annual test volume declaration 08 /30/2019 (last test volume submitted) the laboratory performed 10,000 AFFIRM VPII patient microbial identification tests. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on record review of the laboratory's AFFIRM VPII microbial testing records and interview with the laboratory personnel on 09/10/2020, the laboratory failed to establish and maintain the accuracy of its testing procedures, in accordance with 493. 1236(c)(1), "to at least twice annually verify the accuracy of any test or procedure it performs that is not included in subpart I". The findings included: 1. The laboratory was enrolled in the American Academy of Family Physicians (AAFP) proficiency testing for AFFIRM VPIII (G. vaginalis, Candida sp., T. vaginalis) for events 2020-A and 2020-B, the laboratory failed to verify the accuracy of the tests performed by nonparticipation in both consecutive events of 2020. 2. The laboratory personnel affirmed by interview on 09/10/2020 at 12:30 a.m. that the laboratory failure to perform and document twice annual verification for the AFFIRM VPII (G. vaginalis, Candida sp. and T. vaginalis) testing 3. Based on the laboratory's annual test volume declaration 08/30/2019 (last test volume submitted) the laboratory performed 10,000 AFFIRM VPII patient microbial identification tests. D5891 POSTANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1299(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems specified in 493.1291. This STANDARD is not met as evidenced by: Based on surveyor review of laboratory's policy & procedure, patient test record review from 03/26/2019 to 07/10/2020 for 10 randomly selected patients, and interview with the laboratory personnel on 09/10/2020, at 12:30 a.m. it was -- 2 of 4 -- determined that the laboratory failed to establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems. The findings included: 1. No written policies and procedures for postanalytic system quality assessment reviews could be retrieve. (See D5203). D6017 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(ii) Ensure that results are returned within the timeframes established by the proficiency testing program. This STANDARD is not met as evidenced by: Based on review of the 2020-A and 2020-B American Academy of Family Physicians (AAFP) proficiency events of the AFFIRM VPIII testing records, random patient test results and interview with the laboratory personnel, it was determined that the laboratory director failed to ensure that results are returned within the timeframes established by the proficiency testing program. (See D 5217). D6030 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(12) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(12) Ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills; This STANDARD is not met as evidenced by: Based on the lack of laboratory personnel competency evaluation, the lack of laboratory written policies and procedures for assessing individual performances and interview with the testing person, the laboratory director failed to ensure that policies and procedures are established for monitoring individuals who conduct preanalytical, analytical, and postanalytical phases of testing to assure that they are competent and maintain their competency to process specimens, perform test procedures and report test results promptly and proficiently, and whenever necessary, identify needs for remedial training or continuing education to improve skills. (See D6053, D6054). D6053 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the -- 3 of 4 -- performance of individuals responsible for moderate complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on review and the lack of documentation for competency assessments, and interview with a laboratory personnel, it was determined that the laboratory technical consultant (laboratory director) failed to perform and document the performance of individuals responsible for moderate complexity testing at least semiannually during the first year and yearly thereafter the individual tests patient specimens. The evaluations must include but are not limited to the following: a. No documentation could be retrieved to show that the new testing personnel was evaluated during the first six months (2020) for their responsibilities as testing personnel. The evaluation must include following: Direct observations of the testing performed (including sample handling, processing and testing) Monitoring the recording and reporting of results Direct observation of instrument maintenance Review of intermediate worksheets, quality control records. Assessment of testing previously analyzed specimens (external QC and proficiently testing) Assessment of problem-solving skills 1. The laboratory personnel affirmed 09/10/2020 at 12:30 a.m. (survey date) that no semiannual competency assessment was performed and documented by the technical consultant (laboratory director) on the new testing personnel performing moderate complexity testing in 2020. D6054 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing at least annually, after the first year. This STANDARD is not met as evidenced by: Based on review and the lack of documentation for competency assessments, and interview with the laboratory personnel, it was determined that the laboratory technical consultant (laboratory director) failed to perform and document the performance of individuals responsible for moderate complexity at least annually. The evaluations must include but are not limited to the following: a. No documentation could be retrieved to show that the testing personnel was evaluated at least annually the responsibilities as testing personnel. The evaluation must include following: Direct observations of the testing performed (including sample handling, processing and testing) Monitoring the recording and reporting of results Direct observation of instrument maintenance Review of intermediate worksheets, quality control records. Assessment of testing previously analyzed specimens (external QC and proficiently testing) Assessment of problem-solving skills 1. The laboratory testing personnel confirmed 09/10/2020 (survey date) 12:30 a.m. that no competency assessment could be retrieved evaluating and documenting the performance by the technical consultant (laboratory director) of the testing personnel responsible for moderate complexity testing for 2018 and 2019. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 7, 2019

Survey Type: Special

Survey Event ID: 7X5B11

Deficiency Tags: D2028 D6016 D2016 D6000

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on desk review of CMS proficiency testing (PT) records (i.e. CMS CASPER Reports 0155D entitled, "Individual Laboratory Profile" and CMS CASPER Report 0153D entitled, "Unsuccessful (2 of 3) Report"), it was determined that the laboratory failed to successfully participate in a PT program approved by CMS for each analyte or test in which the laboratory is certified under CLIA. The findings included: The laboratory failed to achieve satisfactory performance in two out of three consecutive testing events in the specialty of Bacteriology, constituting unsuccessful PT performance. (See D2028) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D2028 BACTERIOLOGY CFR(s): 493.823(e) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on desk review of CMS PT records (CMS CASPER Report 0155D and 0153D, it was determined that the laboratory failed to achieve satisfactory performance for two out of three consecutive PT events for Bacteriology, resulting in an "initial" (first) unsuccessful performance. The findings include: a. The laboratory failed to maintain successful performance with the PT program by failing to obtain a score of 80% of acceptable responses in two out of three consecutive PT events for Bacteriology, as follows: 2018 Q3 2019 Q1 Bacteriology 0% 0% Q1 = First Testing Event Q3 = Third Testing Event b. Failure to achieve satisfactory performance for the same analyte or test in two out of three consecutive PT resulted in an initial unsuccessful performance for Bacteriology. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on the severity of the deficiencies cited herein, the Condition: Laboratories Performing Moderate Complexity Testing: Laboratory director was not met. The laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under Subpart H of this part. (See D6016) D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on a desk review of CMS PT records, it was determined the laboratory director, moderate complexity testing, failed to ensure that PT samples were tested as required under subpart H. of this part. The findings included: For the speciality, Bacteriology, the laboratory repeatedly failed to achieve satisfactory performance for two out of three consecutive testing events, resulting in unsuccessful PT performance. (See D2016 and D2028) -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access