Gove County Medical Center

CLIA Laboratory Citation Details

2
Total Citations
6
Total Deficiencyies
5
Unique D-Tags
CMS Certification Number 17D0453076
Address 520 W 5th Street, Quinter, KS, 67752
City Quinter
State KS
Zip Code67752
Phone(785) 754-3341

Citation History (2 surveys)

Survey - November 10, 2021

Survey Type: Standard

Survey Event ID: 7WF811

Deficiency Tags: D5783 D6118

Summary:

Summary Statement of Deficiencies D5783

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - November 13, 2018

Survey Type: Standard

Survey Event ID: OJKX11

Deficiency Tags: D5413 D5445 D5783 D5791

Summary:

Summary Statement of Deficiencies D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: A review of temperature and humidity logs, manufacturer operator manuals and interview with staff revealed the laboratory failed to define an acceptable humidity range for the main laboratory and then document the humidity as required by the GeneXpert Dx system, Architect chemistry system, Sysmex XS-1000i analyzer and the Sysmex CA-600 analyzer. Findings were: 1. Based upon review of temperature and humidity logs humidity was not being documented for the main laboratory room and no range had been established. 2. Architect chemistry manufacturer's operators manual show the instrument requires 10 - 85% humidity. 3. Sysmex XS-1000i and Sysmex CA-600 manufacturer's operators manuals show the instruments require 30 - 85% humidity. 4. GeneXpert Dx System operator manual show the instrument requires 10 - 95% humidity. 5. The above information was confirmed by General Supervisor #1 (refer to laboratory personnel report (CMS-209)) at 9:55 AM on November 13, 2018. D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based upon a review of policies/procedures for microbiology,and virology quality control records and staff interview, the laboratory failed to complete the Individualized Quality Control Plan (IQCP) to demonstrate equivalent quality control . Findings were as follows: a. The laboratory's procedure manual for microbiology showed that the laboratory was performing Quality Control (QC) for the GeneXpert DxSystem ( Cephied) for the analytes Flu A&B, RSV, C Diff, and MRSA every 30 days without doing an IQCP b. The laboratory stated the Manufacture says " External QC only need to be done every 30 days " Documentation failed to be produced at the time of the survey making this statement. The IQCP must have the following elements. 1. Risk Assessment (RA) - must include risk assessment of: a. Specimen b. Test System c. Reagent d. Environment e. Testing Personnel 2. Quality Control Plan (QCP) - describes the practices, resources and procedures to control the quality of a particular test process. 3. Quality Assessment (QA) - the new QCP must be incorporated into the lab's ongoing quality assurance plan, and should include elements of the risk assessment c. The above findings were confined by interview with the lab manager/technical supervisor on 11/13/2018 at 1020 hours in the laboratory. D5783

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access