Gulf Coast Health Center, Inc

CLIA Laboratory Citation Details

7
Total Citations
115
Total Deficiencyies
47
Unique D-Tags
CMS Certification Number 45D0707586
Address 2548 Memorial Blvd, Port Arthur, TX, 77640
City Port Arthur
State TX
Zip Code77640
Phone(409) 983-1161

Citation History (7 surveys)

Survey - November 3, 2023

Survey Type: Special

Survey Event ID: LOKM11

Deficiency Tags: D6000 D6016 D0000 D2016 D2096 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 The following deficiencies are a result of a desk review of proficiency testing scores obtained from the national database and verified with the proficiency testing company. The facility was found to be out of compliance with the conditions of the CLIA program The following CONDITION LEVEL DEFICIENCIES were found to be out of compliance: D2016 - 42 C.F.R. 493.803 Condition: Successful participation [proficiency testing] D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director; D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on a review of the Certification and Survey Provider Enhanced Reporting Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (CASPER) Report 155 Individual Laboratory Profile, American Proficiency Institute (API) records, the facility failed to successfully participate in three of five consecutive testing events for the chemistry analytes chloride (Cl) and sodium (Na), resulting in a non-initial unsuccessful performance. Refer to D2096. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, American Proficiency Institute (API) records from 2022 and 2023, the laboratory failed to satisfactorily perform (80% or greater) three of five testing events for the chemistry analytes chloride (Cl) and sodium (Na). Three out of five unsatisfactory testing event scores result in non- initial unsuccessful PT performance. Findings were: 1. A review of the CASPER Report 155 listed the following scores for the chemistry analytes Cl and Na from 2022 and 2023: 2022 Event 2: CL: 0% Na: 0% 2023 Event 1: CL: 0% Na: 0% 2023 Event 3: CL: 20% Na: 20% 2. A proficiency testing desk review of American Proficiency Institute (API)proficiency testing records from 2022 and 2023 confirmed the above scores for the chemistry analytes Cl and Na. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on a proficiency testing desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, American Proficiency Institute (API) proficiency testing records from 2022 and 2023, the laboratory director failed to ensure successful participation in an HHS approved proficiency testing program for three out of five testing events for the chemistry analytes chloride (Cl) and sodium (Na). Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; -- 2 of 3 -- This STANDARD is not met as evidenced by: Based on a desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, American Proficiency Institute (API) proficiency testing records, the laboratory director failed to ensure successful participation in a HHS approved proficiency testing program for the chemistry analytes chloride (Cl) and sodium (Na) for three of five events from 2022 to 2023, resulting in non-initial unsuccessful performance. Refer to D2096. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 23, 2023

Survey Type: Special

Survey Event ID: UYZR11

Deficiency Tags: D2097 D6000 D6016 D6000 D6016 D0000 D2016 D2097

Summary:

Summary Statement of Deficiencies D0000 Based on a proficiency testing desk review survey performed on March 23, 2023, the laboratory was found to be out of compliance based on the following CONDITION LEVEL DEFICIENCIES: D2016 - 42 C.F.R. 493.803 Condition: Successful participation D6000 - 42 C.F.R. 493.1403 Condition: Laboratory Director, moderate complexity D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on a review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, the American Proficiency Institute (API) testing records, the facility failed to achieve successful performance for Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- two of three consecutive proficiency testing events for the specialty of Routine Chemistry, resulting in unsuccessful performance. Refer to D2097. D2097 ROUTINE CHEMISTRY CFR(s): 493.841(g) Failure to achieve an overall testing event score of satisfactory performance for two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, American Proficiency Institute (API) testing records for 2022 and 2023, the laboratory failed to achieve an overall testing event score of satisfactory performance (80% or greater) for two of three consecutive proficiency testing (PT) events for the specialty of Routine Chemistry. Two out of three testing event scores of unsatisfactory performance result in unsuccessful PT performance. Findings were: 1. A review of the CASPER Report 155 lists the following unsatisfactory scores for the specialty of Routine Chemistry in 2022 and 2023: 2022 - Event 2 - Routine Chemistry - 0% 2023 - Event 1 - Routine Chemistry - 0% 2. A proficiency desk review of American Proficiency Institute (API) proficiency testing (PT) records from 2022 and 2023 confirmed that the laboratory received the following unsatisfactory scores for the specialty of Routine Chemistry: 2022 - Event 2 - Routine Chemistry - 0% 2023 - Event 1 - Routine Chemistry - 0% D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on a desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile American Proficiency Institute (API) testing records, the laboratory director failed to ensure successful participation in an HHS-approved proficiency testing program for Routine Chemistry. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: -- 2 of 3 -- Based on a desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile American Proficiency Institute (API) proficiency testing records, the laboratory director failed to ensure successful participation in an HHS-approved proficiency testing program for Routine Chemistry for two of three consecutive events in 2022 to 2023. Refer to D2097. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - July 21, 2022

Survey Type: Standard

Survey Event ID: 6ZGJ11

Deficiency Tags: D2010 D5439 D5785 D5793 D5793 D0000 D2010 D5439 D5785

Summary:

Summary Statement of Deficiencies D0000 . An onsite survey conducted 07/21/2022 found the laboratory in compliance with 42 CFR Part 493, Requirements for Laboratories. . D2010 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(2) The laboratory must test samples the same number of times that it routinely tests patient samples. This STANDARD is not met as evidenced by: Based on review of the laboratory's policies, review of the laboratory's American Proficiency Institute's (API) proficiency testing (PT) records from 2022, and confirmed in interview, the laboratory failed to have documentation of testing proficiency testing samples the same number of times as patient samples for two of two events reviewed. The findings were: 1. A review of the laboratory's policy Proficiency Testing (LAB005) under Testing Personnel Responsibilities revealed "Guidelines for PT testing are the same as for patients, if patient's samples are normally run in duplicate, so are the PT samples...If a very high or low otherwise unusual result would normally be rechecked with a patient sample, the same rule applies to the PT samples" 2. Review of the laboratory LIS settings revealed the following values as critical lab values: Potassium (K) high 6 mmol/L and low 3 mmol /L Chloride (Cl) high 120 mmol/L Sodium (Na) high 160 mmol/L 3. A review of the laboratory's American Proficiency Institute's proficiency testing records from 2022 revealed the following four proficiency testing sample with results which met the laboratory's criteria for repeat testing with no documentation of the repeat testing. API Event 1 CH-01 K 2.96 mmol/L CH-02 Na 161 mmol/L Cl 123.7 mmol/L K 7.24 mmol /L API Event 2 CH-06 K 7.04 mmol/L CH-07 K 2.86 mmol/L 4. An interview with the technical consultant on 7/21/2022 at 1430 hours in the laboratory confirmed the above findings. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on review of laboratory policy, laboratory documents, the Centers for Medicaid and Medicare Services (CMS) form 116, and confirmed in interview, the laboratory failed to perform calibration twice annually for the Sysmex XP-300 hematology analyzer from August 2021 to June 2022 as described in their policy. The findings include: 1. Review of the laboratory policy titled "Method Validation" section "I" stated the following: "4. Criteria for frequency of recalibration or calibration verification, (v.) At least every 6 months." 2. Review of laboratory documents had the previous calibration verification for the Sysmex XP-300 hematology analyzer being performed on February 10, 2021, with the next calibration verification to be performed on August 9, 2021. Surveyor queried the technical consultant (TC), on 6/21 /2022 at 11:30 hours, for the calibration documentation for August 2021 to current and none was provided. 3. Review of the CMS-116, section VII. "Non-Waived Testing" listed an estimated annual volume for the specialty of hematology at 44,000. 4. In an interview on 6/21/2022 at 12:46 hours, in the conference room, the TC confirmed that the calibration verification had not been performed every six months since February of 2021. D5785

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 3, 2021

Survey Type: Standard

Survey Event ID: FKTJ11

Deficiency Tags: D0000 D2089 D5209 D5215 D5309 D5311 D5400 D5417 D5417 D5429 D5441 D5469 D5469 D5791 D5805 D6000 D6020 D6022 D6028 D0000 D2089 D5209 D5215 D5309 D5311 D5400 D5429 D5441 D5447 D5447 D5481 D5481 D5791 D5805 D6000 D6020 D6022 D6028 D6033 D6036 D6042 D6045 D6054 D6055 D6070 D6033 D6036 D6042 D6045 D6054 D6055 D6070

Summary:

Summary Statement of Deficiencies D0000 The laboratory was found out of compliance with the CLIA regulations. The conditions not met were: D5400 - 42 C.F.R. 493.1250 Condition: Analytic systems; D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director D6033 - 42 C.F.R. 493.1409 Condition: Laboratories performing moderate complexity testing; technical consultant; The facility representative was given an opportunity to provide evidence of compliance with the noted deficiencies, and no such evidence was provided prior to survey exit. D2089 ROUTINE CHEMISTRY CFR(s): 493.841(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3)The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on review of the laboratory policy, CMS national database, laboratory's American Proficiency Institute (API) proficiency testing records from 2019 to 2021, quality assurance records, testing records and confirmed in interview, the laboratory failed to participate for all analytes in the specialty of Chemistry for the second event of 2019. The findings were: 1. Review of the laboratory policy Proficiency Testing (LAB005, effective 1/20/20) under Testing/Service Interruptions revealed "In the event testing cannot be performed due to supplies, equipment or personnel changes Gulf Coast HC will notify the testing/survey agency via phone. Notifications should Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 19 -- be made prior to the deadline of testing if at all possible." 2. A review of the CMS national proficiency testing database revealed a score of "0" for the specialty of Chemistry on the 2nd event of 2019 for this facility. 3. A review of the laboratory's API proficiency testing records for the second event of 2019 revealed the laboratory failed to participate in the proficiency testing and received a score of 0 NR (not reported) for 2019 Chemistry Core API 2nd event for the following 16 analytes: ALT, ALBUMIN, ALK PHOS, AST, TOTAL BILI, CA, TOTAL CL, CHOLESTEROL, HDL, CREATINE, GLUCOSE, K, NA, TOTAL PROTEIN, TRIGL, and BUN. 4. A review of quality assurance records for 2019 revealed the facility had not notified API nor the state agency that they had discontinued chemistry patient testing during the time period of non participation. Surveyor review of testing records confirmed no patient testing were performed from 05/2019 to 12/2020. Cross refer to 5215 5. An interview with the testing person #1 on 6/2/21 at 1135 hours in the conference room confirmed the above findings. D3000 FACILITY ADMINISTRATION CFR(s): 493.1100 Each laboratory that performs nonwaived testing must meet the applicable requirements under 493.1101 through 493.1105, unless HHS approves a procedure that provides equivalent quality testing as specified in Appendix C of the State Operations Manual (CMS Pub. 7). (a) Reporting of SARS-CoV-2 test results During the Public Health Emergency, as defined in 400.200 of this chapter, each laboratory that performs a test that is intended to detect SARS-CoV-2 or to diagnose a possible case of COVID-19 (hereinafter referred to as a "SARS-CoV-2 test") must report SARS-CoV-2 test results to the Secretary in such form and manner, and at such timing and frequency, as the Secretary may prescribe. This CONDITION is not met as evidenced by: I. Based on review of the manufacturer's instructions, laboratory and patient test records from 2020-2021, and confirmed in interview, the laboratory failed to report 21 SARS-CoV-2 positive and negative Antigen test results as required by 400.200 for 5 of 5 days reviewed from 10/01/2020 to 6/3/2021. Findings were: 1. Review of the Instructions for Use for the Sofia 2 SARS Antigen FIA test cassettes (1438905EN00 (03/21)) under CONDITIONS OF AUTHORIZATION FOR THE LABORATORY revealed "authorized laboratories using your product will have a process in place for reporting test results to healthcare providers and relevant public health authorities, as appropriate." 4. Review of the laboratory test records from 2020 to 2021 revealed the laboratory started SARS-CoV-2 Antigen patient testing Sofia 2 SARS Antigen FIA test cassettes on 01/20/21. 5. Review of the laboratory policies available revealed no documentation of a policy/procedure related to SARS-CoV-2 test reporting. 6. Review of the laboratory SARS-CoV-2 Antigen patient test records from 2021 revealed no documentation the laboratory reported 21 of 21 patient positive and negative test records for 5 of 5 days of testing (5/27/21, 2/26/21, 1/25/21, 1/20/21, 1/21/21). Refer to Covid Antigen Patient Alias list. 7. An interview with the testing person #1 on 6/3 /21 at 1425 hours in the laboratory confirmed the above findings. II. Based on review of the manufacturer's instructions, laboratory and patient test records from 2020-2021, and confirmed in interview, the laboratory failed to report 4 postive and negative SARS-CoV-2 Antibody test results as required by 42 CFR 493.41 and 493.1100(a) for 3 of 3 days reviewed from 10/1/2020 to 6/3/2021. Findings were: 1. Review of the Instructions for Use for the Ecotest COVID-19 IgG/IgM Rapid Test Device cassette (Number:1110032033 REV1.4 Effective date: 2020-09-22) under CONDITIONS OF -- 2 of 19 -- AUTHORIZATION FOR THE LABORATORY revealed "authorized laboratories using your product will have a process in place for reporting test results to healthcare providers and relevant public health authorities, as appropriate." 2. Review of the laboratory test records from 2020 to 2021 revealed the laboratory started SARS-CoV- 2 IgG/IgM patient testing using Ecotest COVID-19 IgG/IgM Rapid Test Device on 1 /12/21. 3. Review of the laboratory policies available revealed no documentation of a policy/procedure related to SARS-CoV-2 test reporting. 4. Review of the laboratory SARS-CoV-2 IgG/IgM patient test records from 2021 revealed no documentation the laboratory reported 4 of 4 postivie and negative patient test records for 3 of 3 days of testing (1/19/21, 1/14/21, 1/12/21). Refer to Covid Antibody Patient Alias list. 5. An interview with the testing person #1 on 6/3/21 at 1535 hours in the laboratory confirmed the above findings. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of technical consultant (TC) competency assessment from 2019- 2020, Competency Policy, and confirmed in an interview revealed that the laboratory failed to document 1 of 1 technical consultant (TC) competency assessment. The findings were: 1. Review of Competency Evaluation (Policy# LAB 104) under "Scheduling of Competency Tests" revealed "All employees are required to participate in the program annually and new employees semi-annually." 2. Review of technical consultant competency assessments from 2019-2020 revealed the laboratory had no documentation of competency assessment for technical consultant (TC). 3. Confirmed in an interview with testing personnel #1 (TP#1) on 6/3/21 at 3:08 pm in the lab confirmed technical consultant competency assessment was not documented. D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on review of the CMS national database, 2019 to 2021 American Proficiency Institute (API) proficiency testing records, and confirmed in interview, the laboratory failed to verify the accuracy of their chemistry testing after receiving an artificial score of 100% for 4 of 7 of the chemistry proficiency testing events reviewed. Findings were: 1. Review of the CMS national database revealed the laboratory received "100" for all 16 analytes for 4 of 7 API testing events in 2019 to 2021. 2019 3rd event; 2020 1st, 2nd, 3rd events ALT (SGPT) ALBUMIN ALK PHOS AST (SGOT) BILI, TOTAL CA, TOTAL CL CHOLESTEROL, TOTAL CHOLESTEROL, HDL CREATINE GLUCOSE (NON-WAIVED) K NA TOTAL -- 3 of 19 -- PROTEIN TRIGL BUN 2. Review of the laboratory API test records revealed the laboratory received "100" for Not Graded for the above 4 proficiency testing events for all 16 analytes. 2019 3rd event; 2020 1st, 2nd, 3rd events ALT (SGPT) ALBUMIN ALK PHOS AST (SGOT) BILI, TOTAL CA, TOTAL CL CHOLESTEROL, TOTAL CHOLESTEROL, HDL CREATINE GLUCOSE (NON- WAIVED) K NA TOTAL PROTEIN TRIGL BUN 3. An interview with the testing person #1 on 6/2/21 at 1135 hours in the conference room confirmed the above findings. D5309 TEST REQUEST CFR(s): 493.1241(e) If the laboratory transcribes or enters test requisition or authorization information into a record system or a laboratory information system, the laboratory must ensure the information is transcribed or entered accurately. This STANDARD is not met as evidenced by: Review of patient test records, lab requests and interview of facility personnel found the laboratory failed to accurately enter collection times into the Laboratory Information System (LIS) correctly for seven of seven patient reports between March 2019 and January 2020. The findings included: 1. Review of seven patient reports randomly selected from dates between March 2019 and January 2020 found the collection times did not match the times entered on the requisition as follows: a. Patient 1105419 Collection Date 3/28/2019 9:27 AM Received Date 03/28/2019 9:27 AM b. Patient 1060078 Collection Date 3/20/2019 7:38 AM Received Date 03/20 /2019 7:38 AM c. Patient 1105112 Collection Date 3/18/2019 10:32 AM Received Date 3/18/2019 10:32 AM d. Patient 1059226 Collection Date 3/14/2019 9:32 AM Received Date 3/14/2019 9:32 AM e. Patient 1086800 Collection Date 4/5/2019 9:32 AM Received Date 4/5/2019 9:32 AM f. Patient 1110300 Collection Date 1/23/2020 8: 53 AM Received Date (not documented) g. Patient 1049942 Collection Date 1/23 /2020 1:34 PM Received Date (not documented) 2. Review of seven patient requisitions randomly selected from dates between March 2019 and January 2020 found the collection times did not match the times entered on the requisition as follows: a. Patient 1105419 Collection Date 3/26/2019 11:13 AM b. Patient 1060078 Collection Date 3/15/2019 6:32 PM c. Patient 1105112 Collection Date 3/11/2019 10: 36 AM d. Patient 1059226 Collection Date 3/14/2019 9:05 AM e. Patient 1086800 Collection Date 4/4/2019 1:50 PM f. Patient 1110300 Collection Date 1/23/2020 8:55 AM g. Patient 1049942 Collection Date 1/23/2020 1:34 PM 3. Interview of testing personnel conducted June 2, 2021 at 11:22 AM confirmed that the laboratory is supposed to enter the date and time of collection from the requisition into the LIS. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. -- 4 of 19 -- This STANDARD is not met as evidenced by: I. Based on review of the laboratory policy, surveyor observations, patient final reports, and confirmed in interview, the laboratory failed to follow its policy for specimen labeling for 3 of 4 patient specimens reviewed for chemistry testing on the Alfa Wassermann Ace Axcel chemistry analyzer. Findings included: 1. Review of the laboratory policy Labeling Specimen Tubes (LAB052, effective 8/21/18) revealed "a properly labeled specimen consists of patient's full name, date of birth, date of draw, intials of collector and time specimen was drawn." 2. Surveyor observations on 6/2/21 at 1535 hours in the laboratory revealed 3 of 4 patient specimens with no documentation of the collection date and time per the laboratory policy. Patient ID 67606 Patient ID 67607 Patient ID 67608 3. Review of patient final reports for 6/2/21 revealed the above patient specimens were analyzed and reported. 4. An interview with testing person #1 on 632/21 at 1500 hours in the laboratory confirmed the above findings. II. Based on review of the laboratory and patient test records from 2019 to 2021 and confirmed in interview, the laboratory failed to establish a policy and/or procedure that included the specimen acceptability and rejection for 16 of 16 chemistry analytes performed. Findings included: 1. Review of the laboratory records from 2019 to 2021 revealed the laboratory performed the following 16 chemistry analytes. ALBUMIN ALT (SGPT) ALK PHOS AST (SGOT) BILI, TOTAL CA, TOTAL CL CHOLESTEROL, TOTAL CHOLESTEROL, HDL CREATINE GLUCOSE (NON-WAIVED) K NA TOTAL PROTEIN TRIGL BUN 2. Random review of 14 ACE Alfa Wassermann package inserts revealed the following specimen stability: a. ACE Albumin (REF SA2001) under specimen collection, storage and handling revealed "specimen stable at 4 C for up to 72 hours and frozen at -20 C for 6 months or indefinitely at -70 C" b. ACE ALT (REF SA1052) under specimen collection, storage and handling revealed "specimen stable for 7 days at 4- 8 C and -20 C" c. ACE Alkaline Phosphatase (REF SA2002) under specimen collection, storage and handling revealed "specimen stable at 4 - 8 C and 2 months at -20 C" d. ACE AST (REFSA1053) under specimen collection, storage and handling revealed "specimen activity is stable for 28 days at 4 - 8 C and at least one year at -20 C." e. ACE Total Bilirubin (REF SA1008) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C) and for 6 months frozen (-20 C)." f. ACE Calcium-Arsenazo (REF SA1009) under specimen collection, storage and handling revealed "specimen stable for 7 days at 20-25C, 3 weeks at 4-8C, and 8 months at -20C." g. ACE HDL-C (REF SA1043) under specimen collection, storage and handling revealed " Specimen stable when stored in the refrigerator at 4C for 1 to 7 days." h. ACE BUN/Urea (REF SA2024) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C or frozen (-20 C) for 1 year." i. ACE Creatinine (REFSA1012) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C) and for 3 months frozen (-20 C)." j. ACE Cholesterol (REF SA1010) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C) and for 3 months frozen (-20 C)." k. ACE Direct Bilirubin (REF SA1007) under specimen collection, storage and handling revealed "specimen stable for 7 months refrigerated (4-8C) and for 6 months frozen (-20 C)." l. ACE Glucose (REF SA1014) under specimen collection, storage and handling revealed "specimen stable for 8 hours at 25 C, 72 hours at 4 C." m. ACE Total Protein (REFSA1022) under specimen collection, storage and handling revealed "specimen stable at 4 C for up to 72 hours and 6 months frozen (-20 C) or indefinitely at -70C." n. ACE Triglycerides (REFSA1023) under specimen collection, storage and handling revealed "specimen stable 4-7 days at 4C." 3. Review of the laboratory policy available revealed no documentation of the specimen acceptability and rejection for the above tests. 4. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above -- 5 of 19 -- findings. III. Based on review of the laboratory and patient test records from 2019 to 2021 and confirmed in interview, the laboratory failed to establish a policy and/or procedure that included the specimen acceptability and rejection for 6 of 6 hematology analytes performed. Findings included: 1. Review of the laboratory records from 2019 to 2021 revealed the laboratory performed the following 6 hematology analytes. CELL I.D. OR WBC DIFF RBC HCT (NON-WAIVED) HGB (NON-WAIVED) WBC PLATELETS 2. Review of the laboratory policy available revealed no documentation of the specimen acceptability and rejection for the above tests. 3. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. IV. Based on surveyor observations, review of manufacturer's instructions, laboratory and patient test records from 6/2/21, and confirmed in interview, the laboratory failed to establish the room temperature specimen stability for 13 of 16 analytes on the Alfa Wassermann ACE Axcel chemistry analyzer. Findings included: 1. Surveyor observations on 6/2/21 at 1535 hours in the laboratory revealed the laboratory stored 4 serum specimens for testing on the ACE Axcel chemistry analyzer at room temperature prior to testing. Patient ID 67606 Patient ID 67607 Patient ID 67608 Patient ID 67610 2. Random review of the package inserts for 13 of 16 analytes performed on the ACE Axcel chemistry analyzer revealed no documentation of the room temperature specimen stability. ACE Albumin Reagent (REF SA2001) ACE Total Protein (REF SA1022) ACE Alkaline Phosphatase (REF SA2002) ACE ALT (REF SA1052) ACE AST (REF SA1053) ACE BUN/Urea Reagent (REF SA2024) ACE Magnesium (REF SA2019) ACE Creatinine (REF SA1012) ACE Cholesterol (REF SA1010) ACE Direct Bilirubin (REF 1007) ACE Total Bilirubin (REF SA1008) ACE Glucose (REF SA1014) ACE Triglycerides (REF SA1023) 3. Review of the patient test records from 6/2/21 revealed the laboratory analyzed and reported the above 4 patient tests. 4. An interview with the testing person #1 on 6/3/21 at 1500 hours in the conference room confirmed the above findings. She confirmed that all specimens are stored at room temperature prior to analysis. D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: Based on review of policies, test reports, quality control records, and manufacturer's instructions, the laboratory failed to meet the requirements for the analytic systems, as evidenced by: Findings were: 1.The laboratory failed to establish their own control means and acceptable ranges and failed to verify controls prior to use as instructed by the manufacturer. Refer to D5469 2. The laboratory failed to document two levels of quality control each day of patient testing for chemistry and hematology testing. Refer to D5447-I, II, III 3. The laboratory failed to have an effective quality control program in place to ensure the accuracy and reliability of patient test results for chemistry and hematology testing. Refer to D5441-I, II 4. The laboratory failed to document the -- 6 of 19 -- required maintenance procedures on ACE Axcel for 30 of 30 daily maintenance, 10 of 10 weekly maintenance, and 5 of 5 months reviewed from January to May in 2021. Refer to D5429 D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions, surveyor observations, laboratory quality control and patient test records from 06/2021, and confirmed in interview, the laboratory failed to ensure no control material was used beyond its revised expiration date for 3 of 16 analytes tested on the Alfa Wassermann ACE Axcel chemistry analyzer. Findings included: 1. Review of the package insert for the Alfa Wassermann Level 1 (lot 1501UNCM, exp 11/28/24) and Level 2 (lot 1166UECM, exp 11/28/24) chemistry controls (Ref C-4, Ref C-5) under storage and stability "reconstituted at 2-8 C (when stored tightly capped); ALP, ALT, and AST: 5 days; all other analytes: 7 days" 2. Surveyor observations on 6/3/21 at 1430 hours in the laboratory refrigerator an opened bottle of Level 1 and Level 2 of quality control with an opened date of "5 /26/21" lot 1501UNCM, exp 11/28/24 lot 1166UECM, exp 11/28/24 3. Review of the laboratory records revealed the laboratory used the above quality controls for ALP, ALT, and AST beyond the 5 day open stability on 6/2/21. 4. Review of the laboratory patient test records for 6/2/21 revealed the laboratory performed ALP, ALT, and AST for the following 5 patients: 67606; 67607; 67608; 67609, and 67610. 5. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. She stated that she thought the open stability was 7 days. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on a review of ACE Axcel Clinical Chemistry System Operator's Manual, review of the laboratory's maintenance records, patient records, and confirmed in an interview revealed the laboratory failed to document the required maintenance procedures on ACE Axcel for 30 of 30 daily maintenance, 10 of 10 weekly maintenance, and 5 of 5 months reviewed from January to May in 2021. The Findings were: 1. Review of ACE Axcel Clinical Chemistry System Operator's Manual (P/N 701417, Rev. E - 8/18) under page 268 revealed "The following preventive maintenance procedures are required for the system: Daily (DM-1) Remove Condensation from Reagent Compartment (DM-2) Daily Touchplate Cleaning (DM- 3) Clean Exterior of Probe (DM-4) Clean Probe Alignment (DM-5) Clean and Condition ISE Weekly (WM-1) Clean ISE Sample Port (WM-2) Clean Exterior Surface of Instrument (WM-3) Inspect Air Filters and Clean if Necessary (WM-4) Weekly Touchplate Cleaning Monthly (MM-1) Rinse Probe and Fluid Lines with -- 7 of 19 -- Bleach (MM-2) Clean Cap Assemblies (MM-3) Calibrate Table Offset, Sample Delay, and Optics (MM-4) Clean ISE Reference Housing" 2. Random review of the laboratory's maintenance records revealed the laboratory had no documentation of performing the required maintenance procedures on ACE Axcel for 30 of 30 daily maintenance, 10 of 10 weekly maintenance, and 5 of 5 months from January to May in 2021. Daily: 1/21/21 1/22/21 1/23/21 1/24/21 1/25/21 2/4/21 2/5/21 2/6/21 2/7/21 2 /8/21 2/18/21 2/19/21 2/20/21 2/21/21 2/22/21 3/4/21 3/5/21 3/6/21 3/7/21 3/8/21 3/25 /21 3/26/21 4/15/21 4/16/21 4/17/21 4/18/21 5/1/21 5/2/21 5/8/21 5/9/21 Weekly: 1/14 /21-1/18/21 1/21/21-1/25/21 2/4/21-2/8/21 2/11/21-2/15/21 2/18/21-2/22/21 3/4/21-3/8 /21 3/11/21-3/15/21 3/18/21-3/22/21 4/15/21-4/19/21 5/6/21-5/10/21 Monthly: January, 2021 Feburary, 2021 March, 2021 April, 2021 May, 2021 3. Random review of patient records from 4/7/21-5/24/21 revealed the following 60 patient testing without required maintenance procedures performed on Ace Axcel. 4/7/21 Patient: 1107133 Accession#: 67031 4/16/21 Patient: 1029730 Accession#: 66968 Patient: 1011111 Accession#: 66970 Patient: 1002262 Accession#: 66971 Patient: 1090689 Accession#: 66975 Patient: 1116181 Accession#: 66977 Patient: 1063254 Accession#: 66978 Patient: 1073004 Accession#: 66979 Patient: 1090712 Accession#: 66980 Patient: 1070425 Accession#: 66982 Patient: 1010521 Accession#: 66983 Patient: 1044549 Accession#: 66984 Patient: 1063526 Accession#: 66985 Patient: 1008429 Accession#: 66986 Patient: 1096740 Accession#: 66987 Patient: 1037812 Accession#: 66989 Patient: 1042881 Accession#: 66990 Patient: 1018924 Accession#: 66992 Patient: 1049641 Accession#: 66993 Patient: 1111901 Accession#: 67084 Patient: 1051441 Accession#: 67153 4/28/21 Patient: 1115583 Accession#: 67145 Patient: 1105831 Accession#: 67148 Patient: 1055545 Accession#: 67150 Patient: 1116251 Accession#: 67156 Patient: 1079811 Accession#: 67157 Patient: 1116365 Accession#: 67159 Patient: 1089726 Accession#: 67162 Patient: 1022997 Accession#: 67164 Patient: 1069069 Accession#: 67165 Patient: 1052284 Accession#: 67166 Patient: 1088646 Accession#: 67168 Patient: 1011626 Accession#: 67169 5/3/21 Patient: 1016017 Accession#: 67211 Patient: 1047319 Accession#: 67215 Patient: 1026992 Accession#: 67216 Patient: 1007556 Accession#: 67217 Patient: 1112244 Accession#: 67218 Patient: 1015607 Accession#: 67221 Patient: 1104257 Accession#: 67222 Patient: 1009775 Accession#: 67223 Patient: 1013200 Accession#: 67224 Patient: 1077168 Accession#: 67225 Patient: 1116456 Accession#: 67227 Patient: 1016979 Accession#: 67228 Patient: 1033050 Accession#: 67231 Patient: 1026969 Accession#: 67247 Patient: 1007849 Accession#: 67261 Patient: 1035515 Accession#: 67263 Patient: 1075795 Accession#: 67292 Patient: 1061940 Accession#: 67293 5/14/21 Patient: 1019149 Accession#: 67594 5/21/21 Patient: 1017637 Accession#: 67481 Patient: 1016962 Accession#: 67489 Patient: 1111010 Accession#: 67491 Patient: 1096740 Accession#: 67492 5/24/21 Patient: 1020935 Accession#: 67508 Patient: 1088589 Accession#: 67509 Patient: 1078179 Accession#: 67510 Patient: 1063146 Accession#: 67514 4. An interview with testing person #1 (TP#1) on 6/3/21 at 3:08 pm in the laboratory confirmed the above findings. Key: DM = Daily Maintenance WM = Weekly Maintenance MM = Monthly Maintenance D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials -- 8 of 19 -- using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: I. Based on review of the laboratory's procedures, quality control records and interview of facility personnel, the laboratory failed to have an effective quality control program in place to ensure the accuracy and reliability of patient test results for complete blood counts (CBC) using the Sysmex XP 300 (SN B1754). Findings included: 1. Review of the laboratory's own written procedure titled Laboratory Internal Quality Control (effective 1/15/2020) found on pate 1 under the heading Policy: "All procedures performed in the laboratory are controlled for both accuracy and precision. Control material must be retained ( such as instrument tapes and package inserts ) for at least two years. Results of quality control testing shall be reviewed daily by the laboratory testing personnel and at least monthly by the Manager or designee. All quality control results must be within established guidelines before patient results are released." 2. Review of Hematology quality control records for January 2020 found no documentation of the laboratory testing at least two levels of quality control materials on eight of thirteen dates when patient specimens were reported. a. January 2, 2020 b. January 3, 2020 c. January 6, 2020 d. January 7, 2020 e. January 9, 2020 f. January 13, 2020 g. January 14, 2020 h. January 16, 2020 Levy Jennings graphs ( used to assess performance of quality control materials over time) were requested but not provided. 3. Interview of testing person conducted June 2, 2021 at 3:20 PM confirmed that there was no other documentation of quality control materials being tested in January of 2020. She stated that she cannot print any hematology quality control records from the analyzer or LabDaq. All the information she has available for review has been provided. She went on to say that she did not work during that time. She was on maternity leave. At 3:24 PM, she stated that she prints instrument printouts and gives those to the provider for review. 38387 II. Based on review of the laboratory quality control and patient test records from 2019 to 2021, and confirmed in interview, the laboratory failed to monitor over time the accuracy and precision for 5 of 5 quality control lot numbers for the Alfa Wassermann chemistry analyzer. Findings included: 1. Random review of the quality control data from 2019 and 2021 revealed the laboratory used the following 5 quality control lot numbers for the following 8 analytes Chol, Trig, NA, K, ALP, TP, Alb, CO2. lot 1213UNCM lot 1501UNCM lot 937UECM lot 677UECM lot 889UNCM 2. Review of the laboratory records available revealed no documentation the laboratory monitored over time the accuracy and precision of the above quality controls. 3. Random review of patient test records from 01/2019 to 03/2019 and 04/2021 to 05 /2021 revealed the laboratory performed 15 patient testing using the above quality controls for the 8 analytes: Chol, Trig, NA, K, ALP, TP, Alb, CO2. 1/09/19: 60191, 60196 1/22/19: 60414, 60415 2/06/19: 60739, 60740 2/12/19: 60748 3/05/19: 61270, 61268 5/20/21: 67433 5/21/21: 67467 4/21/21: 67046, 67047 4/22/21: 67068, 67069 4. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) -- 9 of 19 -- Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: I. Based on review of the laboratory's procedure, patient test records, and interview of facility personnel, the laboratory failed to include and document two control materials of different concentrations at least once each day patient specimens were tested for complete blood counts (CBC) using the Sysmex XP 300 (SN B1754). Findings included: 1. Review of the laboratory's own written procedure titled Laboratory Internal Quality Control (effective 1/15/2020) found on pate 1 under the heading Policy: "All procedures performed in the laboratory are controlled for both accuracy and precision. Control material must be retained ( such as instrument tapes and package inserts ) for at least two years. Results of quality control testing shall be reviewed daily by the laboratory testing personnel and at least monthly by the Manager or designee. All quality control results must be within established guidelines before patient results are released." 2. Review of Hematology quality control records for January 2020 found no documentation of the laboratory testing at least two levels of quality control materials on eight of thirteen dates when patient specimens were reported. a. January 2, 2020 b. January 3, 2020 c. January 6, 2020 d. January 7, 2020 e. January 9, 2020 f. January 13, 2020 g. January 14, 2020 h. January 16, 2020 3. Review of patient test records found the laboratory tested 16 patient specimens for CBC between January 2, 2020 and January 16, 2020 without testing at least two levels of quality control material: a. January 2, 2020 - 2 patients tested and reported b. January 3, 2020 - 4 patients tested and reported c. January 6, 2020 - 1 patient tested and reported d. January 7, 2020- 2 patients tested and reported e. January 9, 2020- 1 patient tested and reported f. January 13, 2020- 1 patient tested and reported g. January 14, 2020- 1 patient tested and reported h. January 16, 2020- 4 patients tested and reported 4. Interview of testing person conducted June 3, 2021 at 1:12 PM confirmed that there was no other documentation of quality control materials being tested in January of 2020. She stated that she cannot print any hematology quality control records from the analyzer or LabDaq. All the information she has available for review has been provided. She went on to say that she did not work during that time. She was on maternity leave. 38387 II. Based on review of the laboratory quality control and patient test records from 04/2021 to 05/2021, and confirmed in interview, the laboratory failed to document two levels of quality control each day of patient testing for 2 of 5 days reviewed for chemistry testing on the Alfa Wassermann ACE Axcel chemistry analyzer. Findings included: 1. Random review of the quality control records from 04/2021 to 05/2021 revealed the following 2 of 5 days when no quality control was documented for the following analytes. 4/21/21 ALT TBILI TP HDL TRIG CHOL 5/21/21 CO2 CL K NA 3. Random review of the above dates revealed the laboratory analyzed and resulted for the above analytes for both dates with no quality control for the following 5 patients. 4/21/21: 67046; 67047 5/21/21: 67481; 67489; 67491 4. An interview with the testing person #1 on 6/3/21 at 1420 hours in the conference room confirmed the above findings. She stated that she was performing QC for ALP, ALT and AST every 5 days and the other analytes every 7 days. She was unaware QC was required every day of testing. 44697 III. Based on a review of the laboratory's policy, random review of the laboratory's quality control records for the ACE Axcel from April to May, 2021, review of patient test records, -- 10 of 19 -- and confirmed in an interview revealed that the laboratory failed to have documentation of running two levels of quality control (QC) material for each day of patient testing for 7 of 10 days. The findings were: 1. Review of Laboratory Internal Quality Control (Policy#: LAB108) under 'For Quantitative Assays' revealed "At least two concentrations of analyte in matrix control materials are used where possible and clinical levels should reflect values encountered in patient specimens." 2. Random review of the laboratory's quality control records for ACE Axcel (SN# 20020507) from 4/7/21 to 5/24/21 revealed no documentation of two levels of quality control materials 7 of 7 days prior to patient testing for the following analytes: Cholesterol (CHOL) High Density Lipoprotein (HDL) Triglycerides (TRIG) Dates: 4/7/21 4/16 /21 4/28/21 5/3/21 5/14/21 5/21/21 5/24/21 3. Random review of the laboratory's quality control records for ACE Axcel (SN# 20020507) from 4/7/21 to 5/24/21 revealedno documentation of running two levels of quality control materials 4 of 7 days prior to patient testing for the following analytes: Glucose Dates: 4/7/21 5/3/21 5 /14/21 5/21/21 4. Random review of the laboratory's quality control records for ACE Axcel (SN# 20020507) from 4/7/21 to 5/24/21 revealed the no documentation of one level of quality control materials 3 of 7 days prior to patient testing for the following analytes: Glucose Dates: 4/16/21 5/28/21 5/24/21 5. Random review of patient test records from 4/7/21 to 5/24/21 revealed 60 of 60 patient's results for the above analytes were reported on days when there was no documentation of two levels of quality control material. Date: 4/7/21 Patient Accession#: 67031 Date: 4/16/21 Patient Accession#: 66968 Patient Accession#: 66970 Patient Accession#: 66971 Patient Accession#: 66975 Patient Accession#: 66977 Patient Accession#: 66978 Patient Accession#: 66979 Patient Accession#: 66980 Patient Accession#: 66982 Patient Accession#: 66983 Patient Accession#: 66984 Patient Accession#: 66985 Patient Accession#: 66986 Patient Accession#: 66987 Patient Accession#: 66989 Patient Accession#: 66990 Patient Accession#: 66992 Patient Accession#: 66993 Patient Accession#: 67084 Patient Accession#: 67153 Date: 4/28/21 Patient Accession#: 67145 Patient Accession#: 67148 Patient Accession#: 67150 Patient Accession#: 67156 Patient Accession#: 67157 Patient Accession#: 67159 Patient Accession#: 67162 Patient Accession#: 67164 Patient Accession#: 67165 Patient Accession#: 67166 Patient Accession#: 67168 Patient Accession#: 67169 Date: 5/3/21 Patient Accession#: 67211 Patient Accession#: 67215 Patient Accession#: 67216 Patient Accession#: 67217 Patient Accession#: 67218 Patient Accession#: 67221 Patient Accession#: 67222 Patient Accession#: 67223 Patient Accession#: 67224 Patient Accession#: 67225 Patient Accession#: 67227 Patient Accession#: 67228 Patient Accession#: 67231 Patient Accession#: 67247 Patient Accession#: 67261 Patient Accession#: 67263 Patient Accession#: 67292 Patient Accession#: 67293 Date: 5/14 /21 Patient Accession#: 67594 Date: 5/21/21 Patient Accession#: 67481 Patient Accession#: 67489 Patient Accession#: 67491 Patient Accession#: 67492 Date: 5/24 /21 Patient Accession#: 67508 Patient Accession#: 67509 Patient Accession#: 67510 Patient Accession#: 67514 4. An an interview with a testing personnel#1 (TP#1) on 6 /2/21 at 3:15 pm in the lab confirmed the above findings. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value -- 11 of 19 -- of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions, laboratory quality control and patient test records from 2019 to 2021, and confirmed in interview, the laboratory failed to establish the acceptable ranges for 5 of 5 quality control lot numbers for the Alfa Wassermann chemistry analyzer. Findings included: 1. Review of the package insert for the Alfa Wassermann Level 1 (lot 1501UNCM, exp 11/28/24) and Level 2 (lot 1166UECM, exp 11/28/24) chemistry controls (Ref C-4, Ref C-5) under Assay Values revealed "Each laboratory should establish its own mean and precision parameters." 2. Random review of the quality control data from 2019 and 2021 revealed the laboratory used the following acceptable quality control ranges for the following 5 quality control lot numbers for the following 8 analytes Chol, Trig, NA, K, ALP, TP, Alb, CO2. lot 1213UNCM Chol: 101 - 115 Trig: 93 - 115 NA: 136 - 155.4 K: 3.82 - 4.48 ALP: 60 - 78 TP: 4.4 - 5.0 Alb: 2.9 - 3.5 CO2: 12.4 - 17.2 lot 1501UNCM Chol: 101 - 115 Trig: 93 - 115 NA: 128.5 - 146.9 K: 3.7 - 4.4 ALP: 57.2 - 74.8 TP: 4.4 - 5.0 Alb: 2.6 - 3.2 CO2: 12.9 - 16.9 lot 937UECM Chol: 198 - 226 Trig: 157 - 195 NA: 117.9 - 134.7 K: 6.75 - 7.41 ALP: 341- 445 TP: 6.9 - 7.9 Alb: 4.1 - 4.9 CO2: 27.9 - 36.5 lot 677UECM Chol: 198 - 226 Trig: 157 - 195 NA: 117.9 - 134.7 K: 6.75 - 7.41 ALP: 341 - 445 TP: 6.9 - 7.9 Alb: 4.1 - 4.9 CO2: 27.9 - 36.5 lot 889UNCM Chol: 101 - 115 Trig: 93 - 115 NA: 136 - 155.4 K: 3.82 - 4.48 ALP: 60 - 78 TP: 4.4 - 5.0 Alb: 2.9 - 3.5 CO2: 12.4 - 17.2 3. Review of the laboratory records available revealed no documentation the laboratory established the above quality control ranges. 4. Random review of patient test records from 01/2019 to 03/2019 and 04/2021 to 05/2021 revealed the laboratory performed 15 patient testing using the above quality controls for the 8 analytes: Chol, Trig, NA, K, ALP, TP, Alb, CO2. 1/09 /19: 60191, 60196 1/22/19: 60414, 60415 2/06/19: 60739, 60740 2/12/19: 60748 3/05 /19: 61270, 61268 5/20/21: 67433 5/21/21: 67467 4/21/21: 67046, 67047 4/22/21: 67068, 67069 5. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. D5481 CONTROL PROCEDURES CFR(s): 493.1256(f)(g) (f) Results of control materials must meet the laboratory's and, as applicable, the manufacturer's test system criteria for acceptability before reporting patient test results. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the laboratory policy, review of the laboratory quality control records from 04/2019 to 10/2019, and confirmed in interview, the laboratory failed to ensure quality control were acceptable prior to reporting patient test results for 5 of 10 days reviewed for the analytes ALT and/or AST on the Alfa Wasserman ACE Alera chemistry analyzer. Findings included: 1. Review of the laboratory policy Laboratory Internal Quality Control (LAB108, effective 1/15/2020) under Daily Decision revealed "approximately 95% of all control values should fall within a range of X +/- -- 12 of 19 -- 2 SD. ...The decision whether to accept or reject a run is based on the set of rules developed by Dr. James Westgard et al. Westgard Rules Observed in the Facility: 1.2s = outside 2 sd. On both two level and three level controls, only one level can be >2sd > 3sd 1.3s = outside 3sd. Reject Run 4.1s = Four consecutive control observations exceed the same 1 SD limit. probable causes are problems with standards or calibration of instrument IF the run is rejected using these rules then: A. Hold patient results B. Repeat the patient and controls. If the repeated run is within acceptable limits patient results can be reported. C. If the repeated run is rejected, use fresh controls and repeat B... E. Document any out of control problems with their solution and outcome." 2. Random review of quality control records from 04/2019 to 10/2019 revealed the following 5 of 10 days when 2 levels of quality control were outside of the acceptable ranges for ALT and/or AST with no documentation of the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 3, 2021

Survey Type: Special

Survey Event ID: 2QVW11

Deficiency Tags: D3000 D3000

Summary:

Summary Statement of Deficiencies D0000 The laboratory was found out of compliance with the CLIA regulations. The conditions not met were: D5400 - 42 C.F.R. 493.1250 Condition: Analytic systems; D6000 - 42 C.F.R. 493.1403 Condition: Laboratories performing moderate complexity testing; laboratory director D6033 - 42 C.F.R. 493.1409 Condition: Laboratories performing moderate complexity testing; technical consultant; The facility representative was given an opportunity to provide evidence of compliance with the noted deficiencies, and no such evidence was provided prior to survey exit. D2089 ROUTINE CHEMISTRY CFR(s): 493.841(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3)The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on review of the laboratory policy, CMS national database, laboratory's American Proficiency Institute (API) proficiency testing records from 2019 to 2021, quality assurance records, testing records and confirmed in interview, the laboratory failed to participate for all analytes in the specialty of Chemistry for the second event of 2019. The findings were: 1. Review of the laboratory policy Proficiency Testing (LAB005, effective 1/20/20) under Testing/Service Interruptions revealed "In the event testing cannot be performed due to supplies, equipment or personnel changes Gulf Coast HC will notify the testing/survey agency via phone. Notifications should Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 19 -- be made prior to the deadline of testing if at all possible." 2. A review of the CMS national proficiency testing database revealed a score of "0" for the specialty of Chemistry on the 2nd event of 2019 for this facility. 3. A review of the laboratory's API proficiency testing records for the second event of 2019 revealed the laboratory failed to participate in the proficiency testing and received a score of 0 NR (not reported) for 2019 Chemistry Core API 2nd event for the following 16 analytes: ALT, ALBUMIN, ALK PHOS, AST, TOTAL BILI, CA, TOTAL CL, CHOLESTEROL, HDL, CREATINE, GLUCOSE, K, NA, TOTAL PROTEIN, TRIGL, and BUN. 4. A review of quality assurance records for 2019 revealed the facility had not notified API nor the state agency that they had discontinued chemistry patient testing during the time period of non participation. Surveyor review of testing records confirmed no patient testing were performed from 05/2019 to 12/2020. Cross refer to 5215 5. An interview with the testing person #1 on 6/2/21 at 1135 hours in the conference room confirmed the above findings. D3000 FACILITY ADMINISTRATION CFR(s): 493.1100 Each laboratory that performs nonwaived testing must meet the applicable requirements under 493.1101 through 493.1105, unless HHS approves a procedure that provides equivalent quality testing as specified in Appendix C of the State Operations Manual (CMS Pub. 7). (a) Reporting of SARS-CoV-2 test results During the Public Health Emergency, as defined in 400.200 of this chapter, each laboratory that performs a test that is intended to detect SARS-CoV-2 or to diagnose a possible case of COVID-19 (hereinafter referred to as a "SARS-CoV-2 test") must report SARS-CoV-2 test results to the Secretary in such form and manner, and at such timing and frequency, as the Secretary may prescribe. This CONDITION is not met as evidenced by: I. Based on review of the manufacturer's instructions, laboratory and patient test records from 2020-2021, and confirmed in interview, the laboratory failed to report 21 SARS-CoV-2 positive and negative Antigen test results as required by 400.200 for 5 of 5 days reviewed from 10/01/2020 to 6/3/2021. Findings were: 1. Review of the Instructions for Use for the Sofia 2 SARS Antigen FIA test cassettes (1438905EN00 (03/21)) under CONDITIONS OF AUTHORIZATION FOR THE LABORATORY revealed "authorized laboratories using your product will have a process in place for reporting test results to healthcare providers and relevant public health authorities, as appropriate." 4. Review of the laboratory test records from 2020 to 2021 revealed the laboratory started SARS-CoV-2 Antigen patient testing Sofia 2 SARS Antigen FIA test cassettes on 01/20/21. 5. Review of the laboratory policies available revealed no documentation of a policy/procedure related to SARS-CoV-2 test reporting. 6. Review of the laboratory SARS-CoV-2 Antigen patient test records from 2021 revealed no documentation the laboratory reported 21 of 21 patient positive and negative test records for 5 of 5 days of testing (5/27/21, 2/26/21, 1/25/21, 1/20/21, 1/21/21). Refer to Covid Antigen Patient Alias list. 7. An interview with the testing person #1 on 6/3 /21 at 1425 hours in the laboratory confirmed the above findings. II. Based on review of the manufacturer's instructions, laboratory and patient test records from 2020-2021, and confirmed in interview, the laboratory failed to report 4 postive and negative SARS-CoV-2 Antibody test results as required by 42 CFR 493.41 and 493.1100(a) for 3 of 3 days reviewed from 10/1/2020 to 6/3/2021. Findings were: 1. Review of the Instructions for Use for the Ecotest COVID-19 IgG/IgM Rapid Test Device cassette (Number:1110032033 REV1.4 Effective date: 2020-09-22) under CONDITIONS OF -- 2 of 19 -- AUTHORIZATION FOR THE LABORATORY revealed "authorized laboratories using your product will have a process in place for reporting test results to healthcare providers and relevant public health authorities, as appropriate." 2. Review of the laboratory test records from 2020 to 2021 revealed the laboratory started SARS-CoV- 2 IgG/IgM patient testing using Ecotest COVID-19 IgG/IgM Rapid Test Device on 1 /12/21. 3. Review of the laboratory policies available revealed no documentation of a policy/procedure related to SARS-CoV-2 test reporting. 4. Review of the laboratory SARS-CoV-2 IgG/IgM patient test records from 2021 revealed no documentation the laboratory reported 4 of 4 postivie and negative patient test records for 3 of 3 days of testing (1/19/21, 1/14/21, 1/12/21). Refer to Covid Antibody Patient Alias list. 5. An interview with the testing person #1 on 6/3/21 at 1535 hours in the laboratory confirmed the above findings. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of technical consultant (TC) competency assessment from 2019- 2020, Competency Policy, and confirmed in an interview revealed that the laboratory failed to document 1 of 1 technical consultant (TC) competency assessment. The findings were: 1. Review of Competency Evaluation (Policy# LAB 104) under "Scheduling of Competency Tests" revealed "All employees are required to participate in the program annually and new employees semi-annually." 2. Review of technical consultant competency assessments from 2019-2020 revealed the laboratory had no documentation of competency assessment for technical consultant (TC). 3. Confirmed in an interview with testing personnel #1 (TP#1) on 6/3/21 at 3:08 pm in the lab confirmed technical consultant competency assessment was not documented. D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on review of the CMS national database, 2019 to 2021 American Proficiency Institute (API) proficiency testing records, and confirmed in interview, the laboratory failed to verify the accuracy of their chemistry testing after receiving an artificial score of 100% for 4 of 7 of the chemistry proficiency testing events reviewed. Findings were: 1. Review of the CMS national database revealed the laboratory received "100" for all 16 analytes for 4 of 7 API testing events in 2019 to 2021. 2019 3rd event; 2020 1st, 2nd, 3rd events ALT (SGPT) ALBUMIN ALK PHOS AST (SGOT) BILI, TOTAL CA, TOTAL CL CHOLESTEROL, TOTAL CHOLESTEROL, HDL CREATINE GLUCOSE (NON-WAIVED) K NA TOTAL -- 3 of 19 -- PROTEIN TRIGL BUN 2. Review of the laboratory API test records revealed the laboratory received "100" for Not Graded for the above 4 proficiency testing events for all 16 analytes. 2019 3rd event; 2020 1st, 2nd, 3rd events ALT (SGPT) ALBUMIN ALK PHOS AST (SGOT) BILI, TOTAL CA, TOTAL CL CHOLESTEROL, TOTAL CHOLESTEROL, HDL CREATINE GLUCOSE (NON- WAIVED) K NA TOTAL PROTEIN TRIGL BUN 3. An interview with the testing person #1 on 6/2/21 at 1135 hours in the conference room confirmed the above findings. D5309 TEST REQUEST CFR(s): 493.1241(e) If the laboratory transcribes or enters test requisition or authorization information into a record system or a laboratory information system, the laboratory must ensure the information is transcribed or entered accurately. This STANDARD is not met as evidenced by: Review of patient test records, lab requests and interview of facility personnel found the laboratory failed to accurately enter collection times into the Laboratory Information System (LIS) correctly for seven of seven patient reports between March 2019 and January 2020. The findings included: 1. Review of seven patient reports randomly selected from dates between March 2019 and January 2020 found the collection times did not match the times entered on the requisition as follows: a. Patient 1105419 Collection Date 3/28/2019 9:27 AM Received Date 03/28/2019 9:27 AM b. Patient 1060078 Collection Date 3/20/2019 7:38 AM Received Date 03/20 /2019 7:38 AM c. Patient 1105112 Collection Date 3/18/2019 10:32 AM Received Date 3/18/2019 10:32 AM d. Patient 1059226 Collection Date 3/14/2019 9:32 AM Received Date 3/14/2019 9:32 AM e. Patient 1086800 Collection Date 4/5/2019 9:32 AM Received Date 4/5/2019 9:32 AM f. Patient 1110300 Collection Date 1/23/2020 8: 53 AM Received Date (not documented) g. Patient 1049942 Collection Date 1/23 /2020 1:34 PM Received Date (not documented) 2. Review of seven patient requisitions randomly selected from dates between March 2019 and January 2020 found the collection times did not match the times entered on the requisition as follows: a. Patient 1105419 Collection Date 3/26/2019 11:13 AM b. Patient 1060078 Collection Date 3/15/2019 6:32 PM c. Patient 1105112 Collection Date 3/11/2019 10: 36 AM d. Patient 1059226 Collection Date 3/14/2019 9:05 AM e. Patient 1086800 Collection Date 4/4/2019 1:50 PM f. Patient 1110300 Collection Date 1/23/2020 8:55 AM g. Patient 1049942 Collection Date 1/23/2020 1:34 PM 3. Interview of testing personnel conducted June 2, 2021 at 11:22 AM confirmed that the laboratory is supposed to enter the date and time of collection from the requisition into the LIS. D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. -- 4 of 19 -- This STANDARD is not met as evidenced by: I. Based on review of the laboratory policy, surveyor observations, patient final reports, and confirmed in interview, the laboratory failed to follow its policy for specimen labeling for 3 of 4 patient specimens reviewed for chemistry testing on the Alfa Wassermann Ace Axcel chemistry analyzer. Findings included: 1. Review of the laboratory policy Labeling Specimen Tubes (LAB052, effective 8/21/18) revealed "a properly labeled specimen consists of patient's full name, date of birth, date of draw, intials of collector and time specimen was drawn." 2. Surveyor observations on 6/2/21 at 1535 hours in the laboratory revealed 3 of 4 patient specimens with no documentation of the collection date and time per the laboratory policy. Patient ID 67606 Patient ID 67607 Patient ID 67608 3. Review of patient final reports for 6/2/21 revealed the above patient specimens were analyzed and reported. 4. An interview with testing person #1 on 632/21 at 1500 hours in the laboratory confirmed the above findings. II. Based on review of the laboratory and patient test records from 2019 to 2021 and confirmed in interview, the laboratory failed to establish a policy and/or procedure that included the specimen acceptability and rejection for 16 of 16 chemistry analytes performed. Findings included: 1. Review of the laboratory records from 2019 to 2021 revealed the laboratory performed the following 16 chemistry analytes. ALBUMIN ALT (SGPT) ALK PHOS AST (SGOT) BILI, TOTAL CA, TOTAL CL CHOLESTEROL, TOTAL CHOLESTEROL, HDL CREATINE GLUCOSE (NON-WAIVED) K NA TOTAL PROTEIN TRIGL BUN 2. Random review of 14 ACE Alfa Wassermann package inserts revealed the following specimen stability: a. ACE Albumin (REF SA2001) under specimen collection, storage and handling revealed "specimen stable at 4 C for up to 72 hours and frozen at -20 C for 6 months or indefinitely at -70 C" b. ACE ALT (REF SA1052) under specimen collection, storage and handling revealed "specimen stable for 7 days at 4- 8 C and -20 C" c. ACE Alkaline Phosphatase (REF SA2002) under specimen collection, storage and handling revealed "specimen stable at 4 - 8 C and 2 months at -20 C" d. ACE AST (REFSA1053) under specimen collection, storage and handling revealed "specimen activity is stable for 28 days at 4 - 8 C and at least one year at -20 C." e. ACE Total Bilirubin (REF SA1008) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C) and for 6 months frozen (-20 C)." f. ACE Calcium-Arsenazo (REF SA1009) under specimen collection, storage and handling revealed "specimen stable for 7 days at 20-25C, 3 weeks at 4-8C, and 8 months at -20C." g. ACE HDL-C (REF SA1043) under specimen collection, storage and handling revealed " Specimen stable when stored in the refrigerator at 4C for 1 to 7 days." h. ACE BUN/Urea (REF SA2024) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C or frozen (-20 C) for 1 year." i. ACE Creatinine (REFSA1012) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C) and for 3 months frozen (-20 C)." j. ACE Cholesterol (REF SA1010) under specimen collection, storage and handling revealed "specimen stable for 7 days refrigerated (4-8C) and for 3 months frozen (-20 C)." k. ACE Direct Bilirubin (REF SA1007) under specimen collection, storage and handling revealed "specimen stable for 7 months refrigerated (4-8C) and for 6 months frozen (-20 C)." l. ACE Glucose (REF SA1014) under specimen collection, storage and handling revealed "specimen stable for 8 hours at 25 C, 72 hours at 4 C." m. ACE Total Protein (REFSA1022) under specimen collection, storage and handling revealed "specimen stable at 4 C for up to 72 hours and 6 months frozen (-20 C) or indefinitely at -70C." n. ACE Triglycerides (REFSA1023) under specimen collection, storage and handling revealed "specimen stable 4-7 days at 4C." 3. Review of the laboratory policy available revealed no documentation of the specimen acceptability and rejection for the above tests. 4. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above -- 5 of 19 -- findings. III. Based on review of the laboratory and patient test records from 2019 to 2021 and confirmed in interview, the laboratory failed to establish a policy and/or procedure that included the specimen acceptability and rejection for 6 of 6 hematology analytes performed. Findings included: 1. Review of the laboratory records from 2019 to 2021 revealed the laboratory performed the following 6 hematology analytes. CELL I.D. OR WBC DIFF RBC HCT (NON-WAIVED) HGB (NON-WAIVED) WBC PLATELETS 2. Review of the laboratory policy available revealed no documentation of the specimen acceptability and rejection for the above tests. 3. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. IV. Based on surveyor observations, review of manufacturer's instructions, laboratory and patient test records from 6/2/21, and confirmed in interview, the laboratory failed to establish the room temperature specimen stability for 13 of 16 analytes on the Alfa Wassermann ACE Axcel chemistry analyzer. Findings included: 1. Surveyor observations on 6/2/21 at 1535 hours in the laboratory revealed the laboratory stored 4 serum specimens for testing on the ACE Axcel chemistry analyzer at room temperature prior to testing. Patient ID 67606 Patient ID 67607 Patient ID 67608 Patient ID 67610 2. Random review of the package inserts for 13 of 16 analytes performed on the ACE Axcel chemistry analyzer revealed no documentation of the room temperature specimen stability. ACE Albumin Reagent (REF SA2001) ACE Total Protein (REF SA1022) ACE Alkaline Phosphatase (REF SA2002) ACE ALT (REF SA1052) ACE AST (REF SA1053) ACE BUN/Urea Reagent (REF SA2024) ACE Magnesium (REF SA2019) ACE Creatinine (REF SA1012) ACE Cholesterol (REF SA1010) ACE Direct Bilirubin (REF 1007) ACE Total Bilirubin (REF SA1008) ACE Glucose (REF SA1014) ACE Triglycerides (REF SA1023) 3. Review of the patient test records from 6/2/21 revealed the laboratory analyzed and reported the above 4 patient tests. 4. An interview with the testing person #1 on 6/3/21 at 1500 hours in the conference room confirmed the above findings. She confirmed that all specimens are stored at room temperature prior to analysis. D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: Based on review of policies, test reports, quality control records, and manufacturer's instructions, the laboratory failed to meet the requirements for the analytic systems, as evidenced by: Findings were: 1.The laboratory failed to establish their own control means and acceptable ranges and failed to verify controls prior to use as instructed by the manufacturer. Refer to D5469 2. The laboratory failed to document two levels of quality control each day of patient testing for chemistry and hematology testing. Refer to D5447-I, II, III 3. The laboratory failed to have an effective quality control program in place to ensure the accuracy and reliability of patient test results for chemistry and hematology testing. Refer to D5441-I, II 4. The laboratory failed to document the -- 6 of 19 -- required maintenance procedures on ACE Axcel for 30 of 30 daily maintenance, 10 of 10 weekly maintenance, and 5 of 5 months reviewed from January to May in 2021. Refer to D5429 D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions, surveyor observations, laboratory quality control and patient test records from 06/2021, and confirmed in interview, the laboratory failed to ensure no control material was used beyond its revised expiration date for 3 of 16 analytes tested on the Alfa Wassermann ACE Axcel chemistry analyzer. Findings included: 1. Review of the package insert for the Alfa Wassermann Level 1 (lot 1501UNCM, exp 11/28/24) and Level 2 (lot 1166UECM, exp 11/28/24) chemistry controls (Ref C-4, Ref C-5) under storage and stability "reconstituted at 2-8 C (when stored tightly capped); ALP, ALT, and AST: 5 days; all other analytes: 7 days" 2. Surveyor observations on 6/3/21 at 1430 hours in the laboratory refrigerator an opened bottle of Level 1 and Level 2 of quality control with an opened date of "5 /26/21" lot 1501UNCM, exp 11/28/24 lot 1166UECM, exp 11/28/24 3. Review of the laboratory records revealed the laboratory used the above quality controls for ALP, ALT, and AST beyond the 5 day open stability on 6/2/21. 4. Review of the laboratory patient test records for 6/2/21 revealed the laboratory performed ALP, ALT, and AST for the following 5 patients: 67606; 67607; 67608; 67609, and 67610. 5. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. She stated that she thought the open stability was 7 days. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on a review of ACE Axcel Clinical Chemistry System Operator's Manual, review of the laboratory's maintenance records, patient records, and confirmed in an interview revealed the laboratory failed to document the required maintenance procedures on ACE Axcel for 30 of 30 daily maintenance, 10 of 10 weekly maintenance, and 5 of 5 months reviewed from January to May in 2021. The Findings were: 1. Review of ACE Axcel Clinical Chemistry System Operator's Manual (P/N 701417, Rev. E - 8/18) under page 268 revealed "The following preventive maintenance procedures are required for the system: Daily (DM-1) Remove Condensation from Reagent Compartment (DM-2) Daily Touchplate Cleaning (DM- 3) Clean Exterior of Probe (DM-4) Clean Probe Alignment (DM-5) Clean and Condition ISE Weekly (WM-1) Clean ISE Sample Port (WM-2) Clean Exterior Surface of Instrument (WM-3) Inspect Air Filters and Clean if Necessary (WM-4) Weekly Touchplate Cleaning Monthly (MM-1) Rinse Probe and Fluid Lines with -- 7 of 19 -- Bleach (MM-2) Clean Cap Assemblies (MM-3) Calibrate Table Offset, Sample Delay, and Optics (MM-4) Clean ISE Reference Housing" 2. Random review of the laboratory's maintenance records revealed the laboratory had no documentation of performing the required maintenance procedures on ACE Axcel for 30 of 30 daily maintenance, 10 of 10 weekly maintenance, and 5 of 5 months from January to May in 2021. Daily: 1/21/21 1/22/21 1/23/21 1/24/21 1/25/21 2/4/21 2/5/21 2/6/21 2/7/21 2 /8/21 2/18/21 2/19/21 2/20/21 2/21/21 2/22/21 3/4/21 3/5/21 3/6/21 3/7/21 3/8/21 3/25 /21 3/26/21 4/15/21 4/16/21 4/17/21 4/18/21 5/1/21 5/2/21 5/8/21 5/9/21 Weekly: 1/14 /21-1/18/21 1/21/21-1/25/21 2/4/21-2/8/21 2/11/21-2/15/21 2/18/21-2/22/21 3/4/21-3/8 /21 3/11/21-3/15/21 3/18/21-3/22/21 4/15/21-4/19/21 5/6/21-5/10/21 Monthly: January, 2021 Feburary, 2021 March, 2021 April, 2021 May, 2021 3. Random review of patient records from 4/7/21-5/24/21 revealed the following 60 patient testing without required maintenance procedures performed on Ace Axcel. 4/7/21 Patient: 1107133 Accession#: 67031 4/16/21 Patient: 1029730 Accession#: 66968 Patient: 1011111 Accession#: 66970 Patient: 1002262 Accession#: 66971 Patient: 1090689 Accession#: 66975 Patient: 1116181 Accession#: 66977 Patient: 1063254 Accession#: 66978 Patient: 1073004 Accession#: 66979 Patient: 1090712 Accession#: 66980 Patient: 1070425 Accession#: 66982 Patient: 1010521 Accession#: 66983 Patient: 1044549 Accession#: 66984 Patient: 1063526 Accession#: 66985 Patient: 1008429 Accession#: 66986 Patient: 1096740 Accession#: 66987 Patient: 1037812 Accession#: 66989 Patient: 1042881 Accession#: 66990 Patient: 1018924 Accession#: 66992 Patient: 1049641 Accession#: 66993 Patient: 1111901 Accession#: 67084 Patient: 1051441 Accession#: 67153 4/28/21 Patient: 1115583 Accession#: 67145 Patient: 1105831 Accession#: 67148 Patient: 1055545 Accession#: 67150 Patient: 1116251 Accession#: 67156 Patient: 1079811 Accession#: 67157 Patient: 1116365 Accession#: 67159 Patient: 1089726 Accession#: 67162 Patient: 1022997 Accession#: 67164 Patient: 1069069 Accession#: 67165 Patient: 1052284 Accession#: 67166 Patient: 1088646 Accession#: 67168 Patient: 1011626 Accession#: 67169 5/3/21 Patient: 1016017 Accession#: 67211 Patient: 1047319 Accession#: 67215 Patient: 1026992 Accession#: 67216 Patient: 1007556 Accession#: 67217 Patient: 1112244 Accession#: 67218 Patient: 1015607 Accession#: 67221 Patient: 1104257 Accession#: 67222 Patient: 1009775 Accession#: 67223 Patient: 1013200 Accession#: 67224 Patient: 1077168 Accession#: 67225 Patient: 1116456 Accession#: 67227 Patient: 1016979 Accession#: 67228 Patient: 1033050 Accession#: 67231 Patient: 1026969 Accession#: 67247 Patient: 1007849 Accession#: 67261 Patient: 1035515 Accession#: 67263 Patient: 1075795 Accession#: 67292 Patient: 1061940 Accession#: 67293 5/14/21 Patient: 1019149 Accession#: 67594 5/21/21 Patient: 1017637 Accession#: 67481 Patient: 1016962 Accession#: 67489 Patient: 1111010 Accession#: 67491 Patient: 1096740 Accession#: 67492 5/24/21 Patient: 1020935 Accession#: 67508 Patient: 1088589 Accession#: 67509 Patient: 1078179 Accession#: 67510 Patient: 1063146 Accession#: 67514 4. An interview with testing person #1 (TP#1) on 6/3/21 at 3:08 pm in the laboratory confirmed the above findings. Key: DM = Daily Maintenance WM = Weekly Maintenance MM = Monthly Maintenance D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials -- 8 of 19 -- using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: I. Based on review of the laboratory's procedures, quality control records and interview of facility personnel, the laboratory failed to have an effective quality control program in place to ensure the accuracy and reliability of patient test results for complete blood counts (CBC) using the Sysmex XP 300 (SN B1754). Findings included: 1. Review of the laboratory's own written procedure titled Laboratory Internal Quality Control (effective 1/15/2020) found on pate 1 under the heading Policy: "All procedures performed in the laboratory are controlled for both accuracy and precision. Control material must be retained ( such as instrument tapes and package inserts ) for at least two years. Results of quality control testing shall be reviewed daily by the laboratory testing personnel and at least monthly by the Manager or designee. All quality control results must be within established guidelines before patient results are released." 2. Review of Hematology quality control records for January 2020 found no documentation of the laboratory testing at least two levels of quality control materials on eight of thirteen dates when patient specimens were reported. a. January 2, 2020 b. January 3, 2020 c. January 6, 2020 d. January 7, 2020 e. January 9, 2020 f. January 13, 2020 g. January 14, 2020 h. January 16, 2020 Levy Jennings graphs ( used to assess performance of quality control materials over time) were requested but not provided. 3. Interview of testing person conducted June 2, 2021 at 3:20 PM confirmed that there was no other documentation of quality control materials being tested in January of 2020. She stated that she cannot print any hematology quality control records from the analyzer or LabDaq. All the information she has available for review has been provided. She went on to say that she did not work during that time. She was on maternity leave. At 3:24 PM, she stated that she prints instrument printouts and gives those to the provider for review. 38387 II. Based on review of the laboratory quality control and patient test records from 2019 to 2021, and confirmed in interview, the laboratory failed to monitor over time the accuracy and precision for 5 of 5 quality control lot numbers for the Alfa Wassermann chemistry analyzer. Findings included: 1. Random review of the quality control data from 2019 and 2021 revealed the laboratory used the following 5 quality control lot numbers for the following 8 analytes Chol, Trig, NA, K, ALP, TP, Alb, CO2. lot 1213UNCM lot 1501UNCM lot 937UECM lot 677UECM lot 889UNCM 2. Review of the laboratory records available revealed no documentation the laboratory monitored over time the accuracy and precision of the above quality controls. 3. Random review of patient test records from 01/2019 to 03/2019 and 04/2021 to 05 /2021 revealed the laboratory performed 15 patient testing using the above quality controls for the 8 analytes: Chol, Trig, NA, K, ALP, TP, Alb, CO2. 1/09/19: 60191, 60196 1/22/19: 60414, 60415 2/06/19: 60739, 60740 2/12/19: 60748 3/05/19: 61270, 61268 5/20/21: 67433 5/21/21: 67467 4/21/21: 67046, 67047 4/22/21: 67068, 67069 4. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) -- 9 of 19 -- Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: I. Based on review of the laboratory's procedure, patient test records, and interview of facility personnel, the laboratory failed to include and document two control materials of different concentrations at least once each day patient specimens were tested for complete blood counts (CBC) using the Sysmex XP 300 (SN B1754). Findings included: 1. Review of the laboratory's own written procedure titled Laboratory Internal Quality Control (effective 1/15/2020) found on pate 1 under the heading Policy: "All procedures performed in the laboratory are controlled for both accuracy and precision. Control material must be retained ( such as instrument tapes and package inserts ) for at least two years. Results of quality control testing shall be reviewed daily by the laboratory testing personnel and at least monthly by the Manager or designee. All quality control results must be within established guidelines before patient results are released." 2. Review of Hematology quality control records for January 2020 found no documentation of the laboratory testing at least two levels of quality control materials on eight of thirteen dates when patient specimens were reported. a. January 2, 2020 b. January 3, 2020 c. January 6, 2020 d. January 7, 2020 e. January 9, 2020 f. January 13, 2020 g. January 14, 2020 h. January 16, 2020 3. Review of patient test records found the laboratory tested 16 patient specimens for CBC between January 2, 2020 and January 16, 2020 without testing at least two levels of quality control material: a. January 2, 2020 - 2 patients tested and reported b. January 3, 2020 - 4 patients tested and reported c. January 6, 2020 - 1 patient tested and reported d. January 7, 2020- 2 patients tested and reported e. January 9, 2020- 1 patient tested and reported f. January 13, 2020- 1 patient tested and reported g. January 14, 2020- 1 patient tested and reported h. January 16, 2020- 4 patients tested and reported 4. Interview of testing person conducted June 3, 2021 at 1:12 PM confirmed that there was no other documentation of quality control materials being tested in January of 2020. She stated that she cannot print any hematology quality control records from the analyzer or LabDaq. All the information she has available for review has been provided. She went on to say that she did not work during that time. She was on maternity leave. 38387 II. Based on review of the laboratory quality control and patient test records from 04/2021 to 05/2021, and confirmed in interview, the laboratory failed to document two levels of quality control each day of patient testing for 2 of 5 days reviewed for chemistry testing on the Alfa Wassermann ACE Axcel chemistry analyzer. Findings included: 1. Random review of the quality control records from 04/2021 to 05/2021 revealed the following 2 of 5 days when no quality control was documented for the following analytes. 4/21/21 ALT TBILI TP HDL TRIG CHOL 5/21/21 CO2 CL K NA 3. Random review of the above dates revealed the laboratory analyzed and resulted for the above analytes for both dates with no quality control for the following 5 patients. 4/21/21: 67046; 67047 5/21/21: 67481; 67489; 67491 4. An interview with the testing person #1 on 6/3/21 at 1420 hours in the conference room confirmed the above findings. She stated that she was performing QC for ALP, ALT and AST every 5 days and the other analytes every 7 days. She was unaware QC was required every day of testing. 44697 III. Based on a review of the laboratory's policy, random review of the laboratory's quality control records for the ACE Axcel from April to May, 2021, review of patient test records, -- 10 of 19 -- and confirmed in an interview revealed that the laboratory failed to have documentation of running two levels of quality control (QC) material for each day of patient testing for 7 of 10 days. The findings were: 1. Review of Laboratory Internal Quality Control (Policy#: LAB108) under 'For Quantitative Assays' revealed "At least two concentrations of analyte in matrix control materials are used where possible and clinical levels should reflect values encountered in patient specimens." 2. Random review of the laboratory's quality control records for ACE Axcel (SN# 20020507) from 4/7/21 to 5/24/21 revealed no documentation of two levels of quality control materials 7 of 7 days prior to patient testing for the following analytes: Cholesterol (CHOL) High Density Lipoprotein (HDL) Triglycerides (TRIG) Dates: 4/7/21 4/16 /21 4/28/21 5/3/21 5/14/21 5/21/21 5/24/21 3. Random review of the laboratory's quality control records for ACE Axcel (SN# 20020507) from 4/7/21 to 5/24/21 revealedno documentation of running two levels of quality control materials 4 of 7 days prior to patient testing for the following analytes: Glucose Dates: 4/7/21 5/3/21 5 /14/21 5/21/21 4. Random review of the laboratory's quality control records for ACE Axcel (SN# 20020507) from 4/7/21 to 5/24/21 revealed the no documentation of one level of quality control materials 3 of 7 days prior to patient testing for the following analytes: Glucose Dates: 4/16/21 5/28/21 5/24/21 5. Random review of patient test records from 4/7/21 to 5/24/21 revealed 60 of 60 patient's results for the above analytes were reported on days when there was no documentation of two levels of quality control material. Date: 4/7/21 Patient Accession#: 67031 Date: 4/16/21 Patient Accession#: 66968 Patient Accession#: 66970 Patient Accession#: 66971 Patient Accession#: 66975 Patient Accession#: 66977 Patient Accession#: 66978 Patient Accession#: 66979 Patient Accession#: 66980 Patient Accession#: 66982 Patient Accession#: 66983 Patient Accession#: 66984 Patient Accession#: 66985 Patient Accession#: 66986 Patient Accession#: 66987 Patient Accession#: 66989 Patient Accession#: 66990 Patient Accession#: 66992 Patient Accession#: 66993 Patient Accession#: 67084 Patient Accession#: 67153 Date: 4/28/21 Patient Accession#: 67145 Patient Accession#: 67148 Patient Accession#: 67150 Patient Accession#: 67156 Patient Accession#: 67157 Patient Accession#: 67159 Patient Accession#: 67162 Patient Accession#: 67164 Patient Accession#: 67165 Patient Accession#: 67166 Patient Accession#: 67168 Patient Accession#: 67169 Date: 5/3/21 Patient Accession#: 67211 Patient Accession#: 67215 Patient Accession#: 67216 Patient Accession#: 67217 Patient Accession#: 67218 Patient Accession#: 67221 Patient Accession#: 67222 Patient Accession#: 67223 Patient Accession#: 67224 Patient Accession#: 67225 Patient Accession#: 67227 Patient Accession#: 67228 Patient Accession#: 67231 Patient Accession#: 67247 Patient Accession#: 67261 Patient Accession#: 67263 Patient Accession#: 67292 Patient Accession#: 67293 Date: 5/14 /21 Patient Accession#: 67594 Date: 5/21/21 Patient Accession#: 67481 Patient Accession#: 67489 Patient Accession#: 67491 Patient Accession#: 67492 Date: 5/24 /21 Patient Accession#: 67508 Patient Accession#: 67509 Patient Accession#: 67510 Patient Accession#: 67514 4. An an interview with a testing personnel#1 (TP#1) on 6 /2/21 at 3:15 pm in the lab confirmed the above findings. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value -- 11 of 19 -- of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the manufacturer's instructions, laboratory quality control and patient test records from 2019 to 2021, and confirmed in interview, the laboratory failed to establish the acceptable ranges for 5 of 5 quality control lot numbers for the Alfa Wassermann chemistry analyzer. Findings included: 1. Review of the package insert for the Alfa Wassermann Level 1 (lot 1501UNCM, exp 11/28/24) and Level 2 (lot 1166UECM, exp 11/28/24) chemistry controls (Ref C-4, Ref C-5) under Assay Values revealed "Each laboratory should establish its own mean and precision parameters." 2. Random review of the quality control data from 2019 and 2021 revealed the laboratory used the following acceptable quality control ranges for the following 5 quality control lot numbers for the following 8 analytes Chol, Trig, NA, K, ALP, TP, Alb, CO2. lot 1213UNCM Chol: 101 - 115 Trig: 93 - 115 NA: 136 - 155.4 K: 3.82 - 4.48 ALP: 60 - 78 TP: 4.4 - 5.0 Alb: 2.9 - 3.5 CO2: 12.4 - 17.2 lot 1501UNCM Chol: 101 - 115 Trig: 93 - 115 NA: 128.5 - 146.9 K: 3.7 - 4.4 ALP: 57.2 - 74.8 TP: 4.4 - 5.0 Alb: 2.6 - 3.2 CO2: 12.9 - 16.9 lot 937UECM Chol: 198 - 226 Trig: 157 - 195 NA: 117.9 - 134.7 K: 6.75 - 7.41 ALP: 341- 445 TP: 6.9 - 7.9 Alb: 4.1 - 4.9 CO2: 27.9 - 36.5 lot 677UECM Chol: 198 - 226 Trig: 157 - 195 NA: 117.9 - 134.7 K: 6.75 - 7.41 ALP: 341 - 445 TP: 6.9 - 7.9 Alb: 4.1 - 4.9 CO2: 27.9 - 36.5 lot 889UNCM Chol: 101 - 115 Trig: 93 - 115 NA: 136 - 155.4 K: 3.82 - 4.48 ALP: 60 - 78 TP: 4.4 - 5.0 Alb: 2.9 - 3.5 CO2: 12.4 - 17.2 3. Review of the laboratory records available revealed no documentation the laboratory established the above quality control ranges. 4. Random review of patient test records from 01/2019 to 03/2019 and 04/2021 to 05/2021 revealed the laboratory performed 15 patient testing using the above quality controls for the 8 analytes: Chol, Trig, NA, K, ALP, TP, Alb, CO2. 1/09 /19: 60191, 60196 1/22/19: 60414, 60415 2/06/19: 60739, 60740 2/12/19: 60748 3/05 /19: 61270, 61268 5/20/21: 67433 5/21/21: 67467 4/21/21: 67046, 67047 4/22/21: 67068, 67069 5. An interview with the testing person #1 on 6/3/21 at 1500 hours in the laboratory confirmed the above findings. D5481 CONTROL PROCEDURES CFR(s): 493.1256(f)(g) (f) Results of control materials must meet the laboratory's and, as applicable, the manufacturer's test system criteria for acceptability before reporting patient test results. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the laboratory policy, review of the laboratory quality control records from 04/2019 to 10/2019, and confirmed in interview, the laboratory failed to ensure quality control were acceptable prior to reporting patient test results for 5 of 10 days reviewed for the analytes ALT and/or AST on the Alfa Wasserman ACE Alera chemistry analyzer. Findings included: 1. Review of the laboratory policy Laboratory Internal Quality Control (LAB108, effective 1/15/2020) under Daily Decision revealed "approximately 95% of all control values should fall within a range of X +/- -- 12 of 19 -- 2 SD. ...The decision whether to accept or reject a run is based on the set of rules developed by Dr. James Westgard et al. Westgard Rules Observed in the Facility: 1.2s = outside 2 sd. On both two level and three level controls, only one level can be >2sd > 3sd 1.3s = outside 3sd. Reject Run 4.1s = Four consecutive control observations exceed the same 1 SD limit. probable causes are problems with standards or calibration of instrument IF the run is rejected using these rules then: A. Hold patient results B. Repeat the patient and controls. If the repeated run is within acceptable limits patient results can be reported. C. If the repeated run is rejected, use fresh controls and repeat B... E. Document any out of control problems with their solution and outcome." 2. Random review of quality control records from 04/2019 to 10/2019 revealed the following 5 of 10 days when 2 levels of quality control were outside of the acceptable ranges for ALT and/or AST with no documentation of the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 11, 2021

Survey Type: Special

Survey Event ID: 1HP511

Deficiency Tags: D0000 D2016 D2121 D2130 D2121 D2130 D6000 D6016 D6000 D6016

Summary:

Summary Statement of Deficiencies D0000 Based on a proficiency testing desk review survey performed on March 11, 2021, the laboratory was found to be out of compliance based on the following CONDITION LEVEL DEFICIENCIES: D2016 - 42 C.F.R. 493.803 Condition: Successful participation D6000 - 42 C.F.R. 493.1403 Condition: Laboratory Director, moderate complexity D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and American Proficiency Institute proficiency testing records, the facility failed to achieve successful Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- performance in two of two consecutive testing events for the analyte White Blood Cell Differential (WBC Diff), resulting in unsuccessful performance. Refer to D2121 and D2130. D2121 HEMATOLOGY CFR(s): 493.851(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute (API) Comparative Evaluations, the facility failed to attain a score of at least 80 percent for the analyte White Blood Cell Differential (WBC diff) in two of two consecutive testing events in 2020. The findings included: 1. Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, the laboratory received the following unsatisfactory scores (satisfactory is 80% or greater) for the analyte White Blood Cell Differential in the specialty of Hematology in two of two consecutive events: 2020 API 1st event 0% 2020 API 2nd event 67% D2130 HEMATOLOGY CFR(s): 493.851(f) Failure to achieve satisfactory performance for the same analyte in two consecutive events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and the American Proficiency Institute (API) Comparative Evaluations, the facility failed to achieve satisfactory performance for the analyte White Blood Cell Differential (WBC diff) in two of two consecutive testing events in 2020. The findings included: 1. Based on review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile, the laboratory received the following unsatisfactory scores (satisfactory is 80% or greater) for the analyte White Blood Cell Differential in the specialty of Hematology in two of two consecutive events: 2020 API 1st event 0% 2020 API 2nd event 67% D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and American Proficiency -- 2 of 3 -- Institute (API) proficiency testing records, the laboratory director failed to ensure successful participation in a HHS approved proficiency testing program for analytes White Blood Cell Differential. Refer to D6016. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on desk review of the Certification and Survey Provider Enhanced Reporting (CASPER) Report 155 Individual Laboratory Profile and American Proficiency Institute (API) proficiency testing records, the laboratory director failed to ensure successful participation in a HHS approved proficiency testing program for analyte White Blood Cell Differential (WBC Diff). Refer to D2016. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 21, 2018

Survey Type: Standard

Survey Event ID: BXY911

Deficiency Tags: D2087 D2094 D2122 D2128 D5211 D5400 D5401 D5403 D5421 D6000 D6018 D6019 D6020 D6020 D0000 D2087 D2094 D2122 D2128 D5211 D5400 D5401 D5403 D5421 D6000 D6018 D6019

Summary:

Summary Statement of Deficiencies D0000 Based on the survey conducted 06-20-2018 through 06-21-2018, the laboratory was found to be out of compliance with the following conditions of 42 CFR: 493.1250 Analytic Systems Moderate Complexity 493.1403 Laboratory Director Moderate Complexity . D2087 ROUTINE CHEMISTRY CFR(s): 493.841(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: . Based on review of American Proficiency Institute (API) proficiency testing (PT) documentation for the 2nd testing event of 2017, confirmed by staff interview, the laboratory failed to score at least 80 percent on the analyte total bilirubin. Findings: 1. API chemistry PT documentation for the 2nd event 2017 showed the following score: Bilirubin, Total-60% 2. In an interview at the site on 06-20-2018, testing person 1 (CMS form 209) stated she had performed the testing and reported the results. . D2094 ROUTINE CHEMISTRY CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 7 -- This STANDARD is not met as evidenced by: . Based on review of API proficiency testing documentation for chemistry testing using the Alfa Wasserman Alera analyzer in the 2nd event of 2017, confirmed by staff interview, the laboratory failed to take

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access