Survey - August 11, 2021

Survey Type: Standard

Survey Event ID: 29WV11

Deficiency Tags: D5311

Summary:

Summary Statement of Deficiencies D5311 SPECIMEN SUBMISSION, HANDLING, AND REFERRAL CFR(s): 493.1242(a) The laboratory must establish and follow written policies and procedures for each of the following, if applicable: (1) Patient preparation. (2) Specimen collection. (3) Specimen labeling, including patient name or unique patient identifier and, when appropriate, specimen source. (4) Specimen storage and preservation. (5) Conditions for specimen transportation. (6) Specimen processing. (7) Specimen acceptability and rejection. (8) Specimen referral. This STANDARD is not met as evidenced by: II. Based on observations, review of temperature records ,laboratory policies and procedures, instructions available to clients submitting specimens for testing and interviews it was determined the laboratory failed to follow written policies and procedures for the collection, storage, handling and transportation of gynecologic specimens collected in Hologic PreservCyt solution using the manufacturer's specifications. Findings included: 1. Observations made in the specimen processing area of the laboratory conducted August 19, 2021 at 1:04 PM found gynecologic specimens collected in Hologic PreservCyt solution had been transported at temperatures outside of the manufacturer's specified storage of 15C (59F) and 30C (86F). 18 specimens were transported in refrigerated containers exceeding the minimum storage temperature of 15C. Container for Courier 3 held a thermometer which read 11.9C. It contained 18 PAP specimens in PreservCyt solution. 2. Review of temperature records for August 2021 for this container found: a. Temperature range was defined as 2-20 C. b. Temperatures were recorded three times each day as follows: Date Morning Afternoon Evening 08/02/2021 4 12 19 08/03/2021 5 13 19 08 /04/2021 4 13 19 08/05/2021 5 13 19 08/06/2021 6 12 19 08/07/2021 7 15 08/09/2021 5 6 7 08/10/2021 6 11.9 There was no documentation available for review to define the time each of the specimens was placed into the container used for transport. 2. Review of the laboratory's written instructions for PAP test found under the heading Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Specimen Requirements: "Store vial with cytologic sample intended for ThinPrep Pap testing between 15C (59F) and 30C (86F) for up to 30 days. After 30 days, the sample is discarded as it is no longer valid for HPV testing." 3. Review of the laboratory's written procedure titled THINPREP Specimen Collection and Handling Guide (Rev. 02/01/2021) found on page 2 under the heading Storage and Transportation Instructions: "PreservCyt Solution: Storage: Store the PreserCyte Solution specimen at 15C (59F) and 30C (86F) for up to 30 days. Transportation: Transport the PreserCyte Solution specimen at 15C (59F) and 30C (86F) ." 4. Review of the Hologic ThinPrep 5000 instructions (AW-11239 Rev 2 8-2017) found on page 27: "Store Preservcyt Solution with cytologic sample intended for ThinPrep Pap testing between 15C (59F) and 30C (86F) for up to six weeks". 5. Interview of the General Supervisor conducted on August 10, 2021 at 1:36 PM confirmed that specimens were transported int eh cooler with all specimens and delivered to the primary processing area in the main laboratory. PAP specimens were removed from containers and left in the processing area for accessioning. He stated "getting new coolers validated was nnxt on his list but he hadn't gotten to that just yet". -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 26, 2018

Survey Type: Standard

Survey Event ID: IOI111

Deficiency Tags: D6018 D5221 D5775

Summary:

Summary Statement of Deficiencies D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on review of the College of American Pathologists(CAP) proficiency testing records from 2017 and 2018, policies and procedures and staff interview, the laboratory failed to consistently review, evaluate and document

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 17, 2018

Survey Type: null

Survey Event ID: NPRP12

Deficiency Tags: D5032 D5403 D5617 D5623 D5633 D5635 D5637 D5639 D5641 D5645 D5655 D6115 D6130 D9999 D5209 D5415 D5619 D5629 D5657 D5659 D6108 D6120 D6167

Summary:

Summary Statement of Deficiencies No Tags No deficiency details available. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --