H Richard Reynolds Md

CLIA Laboratory Citation Details

1
Total Citation
4
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 51D0234293
Address 2345 Chesterfield Avenue Suite 204, Charleston, WV, 25304
City Charleston
State WV
Zip Code25304
Phone304 345-3570
Lab DirectorHARRY REYNOLDS

Citation History (1 survey)

Survey - October 1, 2019

Survey Type: Standard

Survey Event ID: FIBL11

Deficiency Tags: D5477 D5891 D5477 D5891

Summary:

Summary Statement of Deficiencies D5477 CONTROL PROCEDURES CFR(s): 493.1256(e)(4)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (4) Before, or concurrent with the initial use-- (e)(4)(i) Check each batch of media for sterility if sterility is required for testing; (e)(4)(ii) Check each batch of media for its ability to support growth and, as appropriate, select or inhibit specific organisms or produce a biochemical response; and (e)(4)(iii) Document the physical characteristics of the media when compromised and report any deterioration in the media to the manufacturer. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on a review of the laboratory quality control (QC) records, patient testing logs, and an interview with the laboratory director (LD), the laboratory failed to (e)(4)(i) check each batch of media for sterility if sterility is required for testing, (e)(4)(ii) check each batch of media for its ability to support growth, and (g) document all control procedures performed. Findings: 1. A review of the laboratory DTM QC log and the patient testing log identified 3 new lots (184901, 1836902, 1833908) of DTM media, that no record of a sterility check or ability to support growth for QC could be located. 2. A review of the laboratory DTM QC log identified 4 new shipments of DTM media on 4/15/19, 5/15/19, 6/17/19, and 7/17/19. There were no lot numbers recorded for each of these shipments. No documentation of the lot numbers received on these dates, or the appropriate QC being performed, could be located. 3. An interview with the LD, on 10/1/19 at approximately 12:15 PM, confirmed the findings. D5891 POSTANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1299(a) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess and, when indicated, correct problems identified in the postanalytic systems specified in 493.1291. This STANDARD is not met as evidenced by: Based on a review of the laboratory written policies and procedures, quality assurance (QA) records, and an interview with the laboratory director (LD), the laboratory failed to follow written policies and procedures for monitoring, assessment, and correction of problems identified in the post analytic system. Findings: 1. A review of the laboratory written policy "Quality Systems Assessment", states "every six months, (February and August of each year) the receptionist/medical assistant pulls ten patient charts.....Those charts (and their respective separate files) are reviewed thoroughly for completeness with respect to.." No documentation of this QA could be located in the 2018 and 2019 records. 2. An interview with the LD, on 10/1/19 at approximately 12: 15 PM, confirmed the findings. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access