Harrison County Community Hospital

CLIA Laboratory Citation Details

3
Total Citations
42
Total Deficiencyies
21
Unique D-Tags
CMS Certification Number 26D0652272
Address 2600 Miller Street, Bethany, MO, 64424
City Bethany
State MO
Zip Code64424
Phone(660) 425-2211

Citation History (3 surveys)

Survey - September 9, 2021

Survey Type: Standard

Survey Event ID: O4WE12

Deficiency Tags: D5291 D5400 D5403 D5291 D5400 D5403 D5447 D5469 D6076 D6093 D6094 D6095 D6098 D5447 D5469 D6076 D6093 D6094 D6095 D6098

Summary:

Summary Statement of Deficiencies D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. This STANDARD is not met as evidenced by: Based on review of procedures and interview with the Chief Executive Officer (CEO), the laboratory failed to establish written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated correct problems. Findings: 1. Review of procedures showed a lack of quality assessment (QA) policies or procedures for an ongoing mechanism to monitor, assess, and, when indicated correct problems. 2. Interview with the CEO on September 9, 2021 at 12:00 PM confirmed the laboratory failed to establish written QA policies or procedures. D5400 ANALYTIC SYSTEMS CFR(s): 493.1250 Each laboratory that performs nonwaived testing must meet the applicable analytic systems requirements in 493.1251 through 493.1283, unless HHS approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub.7), that provides equivalent quality testing. The laboratory must monitor and evaluate the overall quality of the analytic systems and correct identified problems as specified in 493.1289 for each specialty and subspecialty of testing performed. This CONDITION is not met as evidenced by: Based on review of the laboratory's procedure "Laboratory Quality Control Testing Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 6 -- and

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 21, 2021

Survey Type: Standard

Survey Event ID: O4WE11

Deficiency Tags: D5473 D5551 D5807 D6063 D6065 D6086 D6102 D6127 D6128 D5473 D5551 D5807 D6063 D6065 D6086 D6102 D6127 D6128

Summary:

Summary Statement of Deficiencies D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of hematology records and interview with the general supervisor (GS) #1, the laboratory failed to document the quality of staining materials each day of use for manual differentials for 2019, 2020 and to date June 15, 2021. Findings: 1. Review of hematology records showed the laboratory failed to document the quality of staining materials each day of use for manual differentials. 2. Interview with GS #1 on June 15, 2021 at 10:15 AM confirmed the laboratory failed to document the quality of the manual differential stain each day of use. D5551 IMMUNOHEMATOLOGY CFR(s): 493.1271(a)(f) (a) Patient testing. (a)(1) The laboratory must perform ABO grouping, D (Rho) typing, unexpected antibody detection, antibody identification, and compatibility testing by following the manufacturer's instructions, if provided, and as applicable, 21 CFR 606.151(a) through (e). (a)(2) The laboratory must determine ABO group by concurrently testing unknown red cells with, at a minimum, anti-A and anti-B grouping reagents. For confirmation of ABO group, the unknown serum must be tested with known A1 and B red cells. (a)(3) The laboratory must determine the D (Rho) type by testing unknown red cells with anti-D (anti-Rho) blood typing reagent. (f) Documentation. The laboratory must document all control procedures performed, Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- as specified in this section. This STANDARD is not met as evidenced by: Based on review of blood bank procedures and interview with the general supervisor (GS) #1, the laboratory failed to provide a procedure for checking patient history and manually washing cells. Findings: 1. Review of blood bank procedures showed no procedure for checking patient history prior to performing blood bank procedures. Interview with GS #1 stated "blood bank cards and Community Blood Center American Red Cross book is checked for blood bank patient history". 2. Review of blood bank procedures showed no procedure for manually washing cells. The blood bank cell washer has been out of service since summer 2020 and the laboratory has been manually washing cells. 3. Interview with the GS #1 on June 15, 2021 at 1:00 PM confirmed the laboratory failed to provide a blood bank procedure for checking patient history and washing cells manually. D5807 TEST REPORT CFR(s): 493.1291(d) Pertinent "reference intervals" or "normal" values, as determined by the laboratory performing the tests, must be available to the authorized person who ordered the tests and, if applicable, the individual responsible for using the test results. This STANDARD is not met as evidenced by: Based on review of "ABG Lab Reference Ranges" procedure, blood gas patient report, and interview with the general supervisor (GS) #1 , the laboratory failed to ensure the blood gas procedure reference ranges matched the reference ranges on the blood gas patient report. Findings: 1. Review of the "ABG Lab Reference Ranges" procedure showed the reference ranges as: pCO2: 35 - 48 mmHg pO2: 83 - 108 mmHg tHb: 11.7 - 17.4 g/dL O2Hb: 95.0 - 98.0 % COHb: 0.5 - 1.5 % MetHb: 0 - 1.5 % BE: -2.0 - 3.0 mmol/L 2. Review of the blood gas patient report showed the reference ranges as: pCO2: 35 - 45 mmHg pO2: 80 - 100 mmHg tHb: 12.0 - 15.0 g/dL O2Hb: 94.0 - 100.0 % COHb: 0.0 - 2.0 % MetHb: 0.0 - 2.0 % BE: -2.0 - 2.0 mmol/L 3. Interview with the GS #1 on June 15, 2021 at 11:30 AM confirmed the laboratory failed to ensure the blood gas procedure reference ranges matched the reference ranges on the blood gas patient report. D6063 LABORATORY TESTING PERSONNEL CFR(s): 493.1421 The laboratory must have a sufficient number of individuals who meet the qualification requirements of 493.1423, to perform the functions specified in 493. 1425 for the volume and complexity of tests performed. This CONDITION is not met as evidenced by: Based on review of personnel records, interviews with the general supervisor (GS) #1, and director of nursing, the laboratory failed to provide academic qualifications required to perform moderate complexity testing for seventeen of twenty-eight testing personnel. (Refer to D6065) D6065 TESTING PERSONNEL QUALIFICATIONS -- 2 of 5 -- CFR(s): 493.1423(b)(1)(2)(3)(4)(i) (b) Meet one of the following requirements: (b)(1) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located or have earned a doctoral, master's, or bachelor's degree in a chemical, physical, biological or clinical laboratory science, or medical technology from an accredited institution; or (b)(2) Have earned an associate degree in a chemical, physical or biological science or medical laboratory technology from an accredited institution; or (b)(3) Be a high school graduate or equivalent and have successfully completed an official military medical laboratory procedures course of at least 50 weeks duration and have held the military enlisted occupational specialty of Medical Laboratory Specialist (Laboratory Technician); or (b)(4)(i) Have earned a high school diploma or equivalent; and This STANDARD is not met as evidenced by: Based on review of academic credentials and interviews with the general supervisor (GS) #1 and director of nursing, the laboratory failed to provide academic credentials to qualify seventeen of twenty-eight testing personnel. Findings: 1. The laboratory could not provide documentation (academic credentials) to show testing person #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #27, #28, #29, #30, #31, #32, and #33, were qualified to perform moderate complexity testing. 2. Interview with the GS #1 and director of nursing on June 15, 2021 at 11:00 AM confirmed the documents needed to qualify testing personnel #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #27, #28, #29, #30, #31, #32, and #33 were not available for review. D6086 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(3)(ii) The laboratory director must ensure that verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method. This STANDARD is not met as evidenced by: Based on review of Vitros XT 7600, Celldyn Ruby, Gem 5000 Premier verification procedures and interview with the general supervisor (GS) #1, the laboratory director (LD) failed to ensure that verification procedures used were adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method. Findings: 1. Review of Vitros XT 7600 chemistry analyzer showed no reportable range of test results for the test system and no reference intervals (normal values) for the analytes: acetaminophen, albumin, alcohol, alkaline phosphatase, alanine aminotransferase, amonia, amylase, aspartate aminotransferase, vitamin B12, calcium, cholesterol, creatine kinase, creatine kinase MB, chloride, carbamazepine, creatinine, c-reactive protein, digoxin, high density lipoprotein, low density lipoprotein, carbon dioxide, transferrin and iron binding capacity, iron, ferritin, folate, free thyroxine, gamma glutamyl transferase, glucose, potassium, lithium, lipase, magnesium, sodium, phosphate, phenytoin, prostate specific antigen, salicylate, human gonadotropin, total bilirubin, total protein, triglycerides, thyroid stimulating hormone, vitamin D, blood urea nitrogen, uric acid, valproic acid and vancomycin. 2. Review of the Celldyn Ruby hematology analyzer showed no reference intervals (normal values) for the analytes: white blood cell, red blood cell, hemoglobin, hematocrit and platelet. 3. Review of the Gem 5000 Premier blood gas analyzer verification procedure showed -- 3 of 5 -- no reportable range for the analytes: carboxyhemoglobin, methemoglobin and oxygenated hemoglobin. Review of reference intervals (normal values) showed no reference intervals for the analytes: pH, carbon dioxide, oxygen, hemoglobin, carboxyhemoglobin, methemoglobin and oxygenated hemoglobin. 4. Interview with the GS on June 15, 2021 at 1:30 PM confirmed the LD failed to ensure that verification procedures used were adequate to determine reportable range and reference intervals (normal values) are appropriate for the laboratory's patient population.. D6102 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(12) The laboratory director must ensure that prior to testing patients' specimens, all personnel have the appropriate education and experience, receive the appropriate training for the type and complexity of the services offered, and have demonstrated that they can perform all testing operations reliably to provide and report accurate results. This STANDARD is not met as evidenced by: Based on review of personnel records, lack of initial training documentation, and interview with the general supervisor (GS) #1, the laboratory director failed to ensure seventeen of thirty-three testing personnel (TP) received appropriate training prior to testing patient specimens in the point of care testing laboratory located in the emergency department. Findings: 1. Review of personnel records showed the laboratory could not provide documentation for initial training prior to testing patient specimens for TP #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #27, #28, #29, #30, #31, #32, and #33 in the point of care testing laboratory located in the emergency department. 2. Interview with the GS #2 on June 15, 2021 at 11:00 AM confirmed the laboratory director failed to ensure all testing personnel received appropriate training prior to testing patient specimens. D6127 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least semiannually during the first year the individual tests patient specimens. This STANDARD is not met as evidenced by: Based on review of personnel records and interview with the general supervisor (GS) #1, the technical supervisor (TS) failed to evaluate and document the performance of eighteen of thirty-three testing personnel (TP) at least semiannually during the first year the individual tests patient specimens. Findings: 1. Review of 2019/2020/2021 performance evaluations showed the TS failed to perform semi-annual competency evaluations for TP #3 in the laboratory and TP #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #27, #28, #29, #30, #31, #32, and #33 in the point of care testing laboratory located in the emergency department. 2. Interview with GS #1 on June 15, 2021 at 11: 00 AM confirmed, the TS failed to evaluate and document the performance of eighteen of thirty-three TP at least semiannually during the first year the individual tests patient specimens. -- 4 of 5 -- D6128 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(9) The technical supervisor is responsible for evaluating and documenting the performance of individuals responsible for high complexity testing at least annually after the first year, unless test methodology or instrumentation changes, in which case, prior to reporting patient test results, the individual's performance must be reevaluated to include the use of the new test methodology or instrumentation. This STANDARD is not met as evidenced by: Based on review of 2019/2020/2021 personnel competency assessments and interview with the general supervisor (GS) #1, the technical supervisor failed to document annual competency assessments for twenty-two of thirty-three testing personnel (TP) in 2019, 2020 and to date June 15, 2021. Findings: 1. Review of 2019/2020/2021 personnel competency evaluations showed the TS failed to document annual competency assessments for TP #1, #2, #3, #4, and #5 in the laboratory. 2. Review of 2019/2020/2021 personnel competency assessments showed the TS failed to document annual competency assessments for TP #17, #18, #19, #20, #21, #22, #23, #24, #25, #26, #27, #28, #29, #30, #31, #32, and #33 in the point of care testing laboratory located in the emergency department. 3. Interview with the GS #1 on June 15, 2021 at 11:00 AM confirmed the technical supervisor failed to document annual competency assessments for twenty-two of thirty-three TP in 2019, 2020 and to date June 15, 2021. -- 5 of 5 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 22, 2018

Survey Type: Standard

Survey Event ID: 6D0C11

Deficiency Tags: D5209 D5217 D5209 D5217

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of competency procedures, competencies and interview with the technical supervisor the laboratory failed to establish and follow written policies to assess employee competency. Findings: 1. Laboratory policy states initial competency and annual competency will be completed on all new employees. 2. Review of competencies showed new testing personnel #5 and #1 had no initial competency completed. 3. Review of procedure and competencies showed procedure does not include semi-annual competencies on new employees. no semi-annual competency was completed on testing personnel #1, #7, #5 and #6. 4. Review of procedure showed "each technologist will be evaluated on his or her anniversary". No annual competency was completed in 2017 for testing personnel #6 and #1. 5. Interview with the technical supervisor on August 22, 2018 at 10:30 AM confirmed the laboratory did not include semiannual competency on all new testing personnel and did not follow competency procedure. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Based on review of proficiency testing (PT) for 2017 and interview with the technical supervisor, the laboratory failed to verify the accuracy of the Ammonia analyte twice a year in 2017. Findings: 1. Review of PT records for 2017 revealed the laboratory failed to prove accuracy on the nonregulated analyte ammonia twice in 2017. 2 Interview with the technical supervisor on August 22, 2018 at 11:00 AM confirmed the laboratory failed to verify the accuracy of the nonregulated ammonia analyte twice annually for 2017, -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility