Haydel Medical Clinic

CLIA Laboratory Citation Details

1
Total Citation
49
Total Deficiencyies
25
Unique D-Tags
CMS Certification Number 19D0668399
Address 502 Barrow, Houma, LA, 70360
City Houma
State LA
Zip Code70360
Phone(985) 876-2150

Citation History (1 survey)

Survey - January 12, 2023

Survey Type: Standard

Survey Event ID: MEZB11

Deficiency Tags: D3031 D5209 D5209 D5221 D5401 D5409 D5417 D5421 D5429 D5441 D5781 D6013 D5781 D6013 D6014 D6018 D6023 D6024 D6030 D6031 D6032 D6036 D6040 D6042 D0000 D3031 D5221 D5401 D5409 D5413 D5413 D5417 D5421 D5429 D5441 D6014 D6018 D6023 D6024 D6030 D6031 D6032 D6036 D6040 D6042 D6043 D6053 D6043 D6053

Summary:

Summary Statement of Deficiencies D0000 A Validation survey was performed on January 11, 2023 through January 12, 2023 at Haydel Medical Clinic, CLIA ID # 19D0668399. The laboratory was found in compliance with 42 CFR 493 Requirements for Laboratories; however, standard level deficiencies were cited. D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on review of quality control (QC) records and interview with personnel, the laboratory failed to retain QC records associated with range changes for Chemistry testing for at least two (2) years. Findings: 1. In interview on January 11, 2023 at 10: 24 am, the Technical Consultant stated the laboratory no longer performs Vitamin D testing. 2. Review of the laboratory's quality control records for Chemistry for July 2021, August 2022, and November 2022 revealed Vitamin D had unacceptable QC documented for July 16, 2021 and July 21, 2021. 3. In interview on January 11, 2023 at 11:23 am the Technical Consultant stated there was an update from the manufacturer for the quality control ranges for Vitamin D; however, she did not maintain the QC records that included the new ranges and date put into use. The Technical Consultant stated on July 16, 2021 eight (8) patients and July 21, 2021 two (2) patients were reported. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 13 -- and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of the laboratory's policies and interview with personnel, the laboratory failed to establish complete written policies and procedures to assess competency of laboratory personnel. Findings: 1. Review of the laboratory's "Personnel assessments" policy revealed the laboratory did not include a written policy that included the following six (6) procedures as a minimal requirement for assessing the competency of all personnel performing laboratory testing: a) Direct observations of routine patient test performance, including patient preparation, if applicable, specimen handling, processing and testing. b) Monitoring the recording and reporting or test results. c) Review of intermediate test results or worksheets, quality control records, proficiency testing results, and preventative maintenance records. d) Direct observation of performance of instrument maintenance and function checks. e) Assessment of test performance through testing previously analyzed specimens, internal blind testing samples or external proficiency testing samples. f) Assessment of problem solving skills. 2. Further review of the laboratory's "Personnel assessments" policy revealed the laboratory did not include a written procedure that included, but not limited to, monitors assessed and frequency of performance for the competency assessment for personnel serving as Technical Consultant. 3. In interview on January 11, 2023 at 11:21 am, the Technical Consultant confirmed the laboratory's policies did not include the identified information. D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on review of the laboratory's policies, proficiency testing (PT) records, and interview with personnel the laboratory failed to ensure complete documentation of review of PT results. Findings: 1. Review of the laboratory's "Proficiency testing (PT) policy revealed "PT will be reviewed by the technical supervisor, the lab director, and the lab staff at different intervals but no less than described on the Quality Assessment calendar." 2. Review of the laboratory's PT records for 2021 and 2022 revealed an "Investigation of Unacceptable Results" document was used for assessment of unacceptable Lymphocytes % (Sample SXT-15) and Helicobacter pylori (sample HP- 6) results for 2022 Testing Event 3. 3. Further review of the "Investigation of Unacceptable Results" document revealed the laboratory did not complete /include the following information listed on their forms: a) "Survey Event, PT Provider, Date Testing Performed": the information was documented b) "Laboratory Director Review": Laboratory Director did not sign indicating his review; however "11/15/22" was indicated on the date line 4. In interview on January 12, 2023 at 5:00 pm, the Technical Consultant confirmed the identified information and Laboratory Director's review were not included. D5401 PROCEDURE MANUAL CFR(s): 493.1251(a) A written procedures manual for all tests, assays, and examinations performed by the -- 2 of 13 -- laboratory must be available to, and followed by, laboratory personnel. Textbooks may supplement but not replace the laboratory's written procedures for testing or examining specimens. This STANDARD is not met as evidenced by: Based on review of the laboratory's policies and interview with personnel, the laboratory failed to establish a complete policy and procedure manual. Findings: 1. Review of the laboratory's policies revealed the laboratory did not have written policies and procedures that included the following: a) Performance specification: detailed procedures for performing accuracy and precision (day-to-day, run-to-run, and within-run, as well as, operator variance), reportable and reference range studies, and actions to take when data from the studies fail to meet acceptability criteria b) Detailed Complete Blood Count (CBC) flag policy that included a complete list of instrument flags c) Updated SARS COV-2 reporting policy that includes what is reported to state agency d) Proficiency testing: to include, but not limited to, what is assessed and form utilized for documentation of assessment 2. In interview on January 11, 2023 at 12:08 pm, the Technical Consultant confirmed the laboratory did not include the identified polices and procedures. D5409 PROCEDURE MANUAL CFR(s): 493.1251(e) The laboratory must maintain a copy of each procedure with the dates of initial use and discontinuance as described in 493.1105(a)(2). This STANDARD is not met as evidenced by: Based on review of policies and interview with personnel, the laboratory failed to document the dates of discontinuance for tests no longer performed. Findings: 1. Review of the laboratory's "Analytic phase" policy under the "Procedure manual" section revealed "Discontinued procedures are retained for two years and the discontinued date is noted." 2. Review of the laboratory's policies and procedures revealed procedures related to Vitamin D, Vitamin B-12 testing, Helicobacter (H.) pylori (waived) testing. 3. In interview on January 11, 2023 at 10:24 am, the Technical Consultant stated the laboratory no longer performs Vitamin D testing. 4. In interview on January 11, 2023 at 11:08 am, the Technical Consultant stated the laboratory discontinued the Aim Step H. pylori test. 5. In further interview on January 11, 2023 at 1:11 pm. the Technical Consultant stated the laboratory no longer performs Vitamin D and Vitamin B-12 testing as of September 2021. 6. Further review of the laboratory's policies and procedures revealed the laboratory did not include the date of discontinuance for the identified tests. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. -- 3 of 13 -- This STANDARD is not met as evidenced by: Based on observation by surveyors, review of manufacturers' requirements, and interview with personnel, the laboratory failed to monitor the temperature where sample collection supplies were stored per manufacturer requirements. Findings: 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the following items stored in the phlebotomy area without temperature monitoring: a) BD Vacutainer K2EDTA blood collection tubes, Lot 2227125, Quantity: three (3) packs b) BD Vacutainer SST blood collection tubes, Lot 2291711, Quantity: three (3) packs c) 100 esr vacuum tubes, Lot 12010851, Quantity: one (1) box d) BD Vacutainer serum blood collection tubes, Lot 2161937, Quantity: fifteen (15) tubes e) BD Vacutainer serum blood collection tubes, Lot 1349713, Quantity: eight (8) tubes f) Fisherbrand Microorganism Collection and Transport Tubes, Lot 2G11A, Quantity: seven (7) tubes 2. Review of the manufacturers' storage requirements for the identified sample collection supplies revealed the following: a) BD Vacutainer K2EDTA blood collection tubes: storage requirement 4-25 degrees Celsius b) BD Vacutainer SST blood collection tubes: storage requirement 4-25 degrees Celsius c) 100 esr vacuum tubes: storage requirement 2-30 degrees Celsius d) BD Vacutainer serum blood collection tubes: storage requirement 4-25 degrees Celsius e) Fisherbrand Microorganism Collection and Transport Tubes: storage requirement 4-25 degrees Celsius 3. In interview on January 11, 2023 at 10:15 am, the Technical Consultant stated the temperature is not monitored in the phlebotomy area. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on observation by surveyors, review of the laboratory's policies, and interview with personnel, the laboratory failed to ensure supplies and reagents did not exceed their expiration dates. Findings: 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the following expired items: a) Hologic Aptima Urine Specimen Transport Tubes, Lot 284808, Expiration Date: 11-30-21, Quantity: fourteen (14) tubes b) BD Vacutainer SST blood collection tubes, Lot 0275632, Expiration Date: 2021-09-30, Quantity: one (1) tube c) BD Vacutainer KEDTA, Lot 1014105, Expiration Date: 2022-05-31, Quantity: one (1) tube d) FP Cal, Lot 54164101, Expiration Date: 2022-12-31, Quantity: one (1) pack e) Elecsys SysWash, Lot 54639801, Expiration Date: 2022-07-31, Quantity: one (1) bottle f) Elecsys Vitamin B12 11, Lot 54148101, Expiration Date: 2022-12-31, Quantity: one (1) box 2. Review of the laboratory's policies under the "Test systems, equipment, instruments, reagents, materials, and supplies" section revealed "Reagents, materials, and supplies are not used beyond expiration dates." 3. In interview on January 11, 2023 at 10:37 am, the Technical Consultant confirmed the identified items were expired. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) -- 4 of 13 -- Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: I. Based on observation by surveyors, review of policies, review of performance specification studies, and interview with personnel, the laboratory failed to ensure complete verification of performance specification studies for Chemistry testing. Findings: 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the laboratory utilizes the following instruments for Chemistry testing: Cobas Integra 400 plus Cobas e411 2. In interview on January 11, 2023 at 1: 30 pm, the Technical Consultant stated after Hurricane Ida the laboratory re-validated the Chemistry and Hematology analyzers in June 2022 by performing a full validation as if new instruments. 3. Review of the laboratory's performance specification (validation) studies revealed the following information was not included: a) Acceptability criteria for correlations b) Accuracy performed over the course of ten (10) days as stated in summary c) Precision studies to include, day to day over the course of ten (10) days as stated in summary d) Reportable ranges in summary chart did not match the raw data 4. In further interview on January 11, 2023 at 1:30 pm, the Technical Consultant confirmed the identified information was not included in the laboratory's performance verification studies of the Chemistry analyzers. II. Based on observation by surveyors, review of policies, review of performance specification studies, and interview with personnel, the laboratory failed to ensure complete verification of performance specification studies for Hematology testing. Findings 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the laboratory utilizes the Sysmex XN 430 for Hematology testing. 2. In interview on January 11, 2023 at 1:30 pm, the Technical Consultant stated after Hurricane Ida the laboratory re-validated the Chemistry and Hematology analyzers in June 2022 by performing a full validation as if new instruments. 3. Review of the laboratory's performance specification (validation) studies revealed the following information was not included: a) Acceptability criteria for correlations b) Accuracy performed over the course of ten (10) days as stated in summary c) Precision studies to include, day to day over the course of ten (10) days as stated in summary d) Reportable ranges in summary chart did not match the raw data 4. In further interview on January 11, 2023 at 1:30 pm, the Technical Consultant confirmed the identified information was not included in the laboratory's performance verification studies of the Hematology analyzer. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: I. Based on observation by surveyors, review of maintenance logs, policies, and -- 5 of 13 -- interview with personnel, the laboratory failed to ensure maintenance was performed as required for the Cobas e411 analyzer as required for two (2) of seven (7) months reviewed in 2022. Findings: 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the laboratory utilizes the following Chemistry analyzers: Cobas Integra 400 plus Cobas e411 2. In interview on January 11, 2023 at 9:39 am, the Technical Consultant stated the laboratory was closed September 1, 2021 through middle of June 2022 due to Hurricane Ida. 3. Review of the laboratory's "Maintenance and function Checks" policy revealed "A review of maintenance checks will be done at least annually. The review will include" All maintenance follows manufacturer instructions, all maintenance (daily, weekly, biweekly, monthly) is performed and documented, and all function checks are within manufactures {sic} limits before patient testing begins." 4. Review of the Cobas e411 maintenance logs revealed the following tasks: a) Weekly: Clean incubator and aspiration station Clean sipper probe b) Every two (2) weeks: Clean rinse stations Perform liquid flow cleaning 5. Further review of the laboratory's maintenance logs for the Cobas e411 from June 2022 through December 2022 revealed the following maintenance was not documented as required: a) September 2022: Weekly: missing for the week of September 5, 2022 and September 26, 2022 Every two (2) weeks: missing for the week of September 26, 2022 b) November 2022: Weekly: missing for the week of November 28, 2022 Every two (2) weeks: missing for the weeks of November 14, 2022 and November 28, 2022 6. In interview on January 12, 2023 at 12:26 pm, the Technical Consultant stated maintenance is documented on the maintenance logs and if it is not documented there then it was not performed. II. Based on observation by surveyors, review of maintenance logs, and interview with personnel, the laboratory failed to ensure maintenance was performed as required for the Cobas Integra 400 plus analyzer as required for nine (9) of fifteen (15) months reviewed. Findings: 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the laboratory utilizes the following Chemistry analyzers: Cobas Integra 400 plus Cobas e411 2. In interview on January 11, 2023 at 9:39 am, the Technical Consultant stated the laboratory was closed September 1, 2021 through middle of June 2022 due to Hurricane Ida. 3. Review of the laboratory's "Maintenance and function Checks" policy revealed "A review of maintenance checks will be done at least annually. The review will include" All maintenance follows manufacturer instructions, all maintenance (daily, weekly, biweekly, monthly) is performed and documented, and all function checks are within manufactures {sic} limits before patient testing begins." 4. Review of the Cobas Integra 400 plus maintenance logs revealed the following tasks: a) Weekly: Clean probes and splash guard Clean ISE tower automatically Back up database b) Monthly: Clean waste box fitting Clean ISE tower manually c) Quarterly: Replace ventilation filters Replace external water reservoir filter d) Semi-annual: Clean external water reservoir Clean fluid water reservoir Clean internal water reservoir Clean wash station Replace ISE tubing e) Electrode replacement frequency: Chloride electrode every 90 days Lithium electrode every 120 days Sodium electrode every 180 days Potassium electrode every 180 days Reference electrode every 720 days 5. Further review of the laboratory's maintenance logs for the Cobas Integra 400 plus revealed the following maintenance was not documented as required for 2021 and 2022: a) January 2021: Chloride electrode replacement due b) March 2021: Weekly: missing for the week of March 22, 2021 c) May 2021: Weekly: missing for the week of May 3, 2021 d) July 2021: Chloride electrode replacement due e) August 2021: Monthly: Clean ISE tower manually f) August 2022: Weekly: missing for the week of August 15, 2022 g) September 2022: Weekly: missing for the week of September 19, 2022 Quarterly due Chloride electrode replacement due (performed November 10, 2022) h) November 2022: Monthly: Clean ISE tower manually i) December 2022: Semi-annual due 6. In -- 6 of 13 -- interview on January 12, 2023 at 12:26 pm, the Technical Consultant stated maintenance is documented on the maintenance logs and if it is not documented there then it was not performed. III. Based on observation by surveyors, review of maintenance logs, and interview with personnel, the laboratory failed to ensure maintenance was performed as required for the Sysmex XN-430 analyzer as required for three (3) of fifteen (15) months reviewed. Findings: 1. Observation by surveyors during the laboratory tour on January 11, 2023 at 10:04 am revealed the laboratory utilizes the Sysmex XN-430 for Complete Blood Count (CBC) testing. 2. In interview on January 11, 2023 at 9:39 am, the Technical Consultant stated the laboratory was closed September 1, 2021 through middle of June 2022 due to Hurricane Ida. 3. Review of the laboratory's XN-430 Maintenance logs revealed the following maintenance tasks: a) Weekly: routine cleaning 4. Further review of the laboratory's maintenance logs for the Sysmex XN-430 revealed the following maintenance was not documented as required for 2021 and 2022: a) November 2021: Weekly: missing for the week of November 22, 2021 b) December 2021: Weekly: missing for the week of December 27, 2021 c) April 2022: Weekly: missing for the week of April 11, 2022 d) May 2022: Weekly missing for the week of May 23, 2022 e) November 2022: Weekly: missing for the week of November 21, 2022 5. In interview on January 12, 2023 at 12:26 pm, the Technical Consultant stated maintenance is documented on the maintenance logs and if it is not documented there then it was not performed. D5441 CONTROL PROCEDURES CFR(s): 493.1256(a)(b)(c)(g) (a) For each test system, the laboratory is responsible for having control procedures that monitor the accuracy and precision of the complete analytic process. (b) The laboratory must establish the number, type, and frequency of testing control materials using, if applicable, the performance specifications verified or established by the laboratory as specified in 493.1253(b)(3). (c) The control procedures must-- (c)(1) Detect immediate errors that occur due to test system failure, adverse environmental conditions, and operator performance. (c)(2) Monitor over time the accuracy and precision of test performance that may be influenced by changes in test system performance and environmental conditions, and variance in operator performance. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the laboratory's quality control (QC) policies and interview with personnel, the laboratory failed to establish complete QC policies for Chemistry and Hematology testing. Findings: 1. Review of the laboratory's "Quality Control Policy" revealed "The mean target value of a new lot of quality control material will be calculated by evaluating at least 20 days of quality control results run in parallel with the current quality control lot. Values for standard deviation and coefficient of variation are calculated and a Levy-Jennings plot is created. Daily QC results are plotted on this chart." 2. Further review of the laboratory's "Quality Control Policy" under the "Procedure For Out of Range Quality Control Results" revealed the laboratory did not include when to perform patient assessment. 3. Further review of the laboratory's policies under "New Lots" section revealed "New lots of controls will be run 5 times to verify the manufacturer mean and standard deviation," which differed from the "Quality Control Policy." 4. In interview on January 11, 2023 at 9: 55 am, the Technical Consultant stated prior to use of a new lot on controls for Chemistry testing the controls are run five (5) times and the means are compared to that of the manufacturer's. The Technical Consultant further stated prior to use of a -- 7 of 13 -- new lot of controls for Hematology testing the controls are run ten (10) times to verify the manufacturer's. The Technical Consultant confirmed the laboratory's QC policies did not match what was in practice. D5781

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access