Hightower Dermatology

CLIA Laboratory Citation Details

2
Total Citations
7
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 10D2167996
Address 957 E Del Webb Blvd Ste 101, Sun City Center, FL, 33573
City Sun City Center
State FL
Zip Code33573
Phone(813) 634-1484

Citation History (2 surveys)

Survey - August 7, 2025

Survey Type: Standard

Survey Event ID: 2CEZ11

Deficiency Tags: D5415 D6093 D0000 D6080

Summary:

Summary Statement of Deficiencies D0000 An unannounced CLIA recertification survey was conducted at Hightower Dermatology on 08/07/25. The laboratory is not in compliance with 42 CFR Part 493, Requirements for Laboratories. The following is a description of the standard level deficiencies: D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) (c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (c)(1) Identity and when significant, titer, strength or concentration. (c)(2) Storage requirements. (c)(3) Preparation and expiration dates. (c)(4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on observation, record review, and interview, three of three tissue inks used for Histology patient testing failed to be labeled with identity, preparation and expiration dates. Findings Included: 1. On 08/07/25 at 10:20 a.m., three of three Formalin containers filled with tissue inks used for Histology patient testing failed to be labeled with identity, preparation and expiration dates. 2. The Laboratory Director on 08/07 /25 at 10:20 a.m. confirmed the three of three Formalin containers were filled with tissue inks used for Histology patient testing failed to be labeled with identity, preparation and expiration dates. 3. The Chemical Reagent Logs for 2023, 2024, and 2025 failed to have documentation of lot number, expiration date, and date received for Tissue Ink for 2023, 2024, and 2025. The Laboratory Director on 08/07/25 at 10: 50 a.m. confirmed the laboratory failed to document and monitor the lot number, expiration date, and date received for Tissue Ink. D6080 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(c) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (c) The laboratory director must: (c)(1) Be onsite at least once every 6 months, with at least 4 months between the minimum two on-site visits. Laboratory directors may elect to be on-site more frequently and must continue to be accessible to the laboratory to provide telephone or electronic consultation as needed; and (c)(2) Provide documentation of these visits, including evidence of performing activities that are part of the laboratory director responsibilities. This STANDARD is not met as evidenced by: Based on record review and interview, the Laboratory Director failed to establish a policy to reflect the requirement of being onsite once every 6 months to include evidence of performing activities that are part of the Laboratory Director's responsibilities. Findings included: 1. The policy and procedure manual, which had approval dates for each policy and procedure individually, was reviewed. No policy could be found regarding documenting being on site every 6 months to include evidence of performing activities that are part of the Laboratory Director's responsibilities. 2. An interview was conducted with the Office Manager on 08/07/25 at 11:00 a.m. The Office Manager stated the laboratory had not been aware of this requirement. D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) (e)(5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur; This STANDARD is not met as evidenced by: Based on record review and interview, the Laboratory Director failed to establish a comprehensive quality assessment program to encompass all laboratory services for 06 /2023-8/2025. Findings included: 1. The policy and procedure manual, which had approval dates for each policy and procedure individually, was reviewed but failed to include a quality assessment procedure to encompass General, Pre-Analytic, Analytic, and Post-Analytic systems. There was no documentation provided for review at the time of the survey of the Laboratory Director performing quality assessment checks of all the laboratory systems. 2. The Laboratory Director on 08/07/25 at 10:50 a.m. confirmed there was no policy or documents to review of comprehensive quality assessment by the Laboratory Director. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 2, 2021

Survey Type: Standard

Survey Event ID: HXAP11

Deficiency Tags: D3011 D0000 D5209

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Hightower Dermatology on 03/02/2021. The laboratory is not in compliance with 42 CFR Part 493, Requirements for Laboratories. The following is a description of the standard level deficiencies: D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on observations, record review, and interview with the General Supervisor the laboratory failed to dispose of Eosin, 95% Reagent Alcohol, and Xylene Substitute per the manufacturer instructions since 10/02/2019. Findings Included: During a tour of the laboratory on 03/02/2021 at 12:30 PM it was observed that there was no chemical waste container in the flammable cabinet. Review of the manufacturer instructions on the bottle of Eosin, 95% Reagent Alcohol, and Xylene Substitute stated to "Dispose of contents/container to an approved waste disposal plant." On 03 /02/2021 at 12:30 PM, the General Supervisor confirmed that the Eosin, 95% Reagent Alcohol, and Xylene Substitute were disposed of down the sink. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on record review and interview with the General Supervisor, the laboratory failed to have competency evaluations on the General Supervisor and Testing Person #B since 10/02/2019. Findings Included: Review of the CMS 209 (signed by the Laboratory Director on 03/02/2021) revealed that the General Supervisor was also Testing Person #B. Review of personnel records revealed no competency evaluations for the General Supervisor and Testing Person #B since 10/02/2019. On 03/02/2021 at 1:30 PM, the General Supervisor confirmed that there was no competency evaluations done for him as General Supervisor or Testing Person. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access