Idaho Urologic Institute

CLIA Laboratory Citation Details

4
Total Citations
13
Total Deficiencyies
13
Unique D-Tags
CMS Certification Number 13D0977077
Address 2855 E Magic View Dr, Meridian, ID, 83642
City Meridian
State ID
Zip Code83642
Phone208 639-4900
Lab DirectorADAM COLE

Citation History (4 surveys)

Survey - July 15, 2024

Survey Type: Standard

Survey Event ID: 2WSJ11

Deficiency Tags: D2009 D5209 D5211 D5215 D5439

Summary:

Summary Statement of Deficiencies D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) documentation from the College of American Pathologists (CAP) and an interview with the technical supervisor (TS) on 7 /15/2024, the laboratory failed to have testing personnel and the laboratory director attest to the integration of PT samples with routine testing of patient samples in 2023. The findings include: 1. A review of PT results from CAP identified that the laboratory failed to have the performing testing personnel and the laboratory director attest that PT samples were integrated with patient samples for hematology automatic differential 2023 event A and the laboratory director attest that PT samples were integrated with patient samples for hematology automatic differential 2023 event C. 2. An interview with the TS on 7/15/2024 at 9:49 am confirmed the above findings. 3. The laboratory reports performing 3,695 automated differentials annually. D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on a review of the Centers for Medicare and Medicaid Services (CMS) 209 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- personnel form, competency assessment records and an interview with the technical supervisor (TS) on 7/15/2024, the laboratory failed to follow written policies and procedures to assess testing personnel in 2023 and 2024. The findings include: 1. A review of the CMS 209 form identified five (5) testing personnel, three (3) with start dates after the previous inspection on 8/9/2022. 2. A review of competency assessment records identified the laboratory failed to have annual competency for each system/test for two (2) testing personnel in 2023. 3. A review of competency assessment records identified the laboratory failed to have six month competency assessments for two (2) testing personnel in 2024. 4. A review of competency assessment records identified the laboratory failed to have documentation of initial training for one (1) testing personnel in 2024. 5. An interview with the TS on 7/15 /2024 at 8:53 am confirmed the above findings. 6. The laboratory reports performing 85,696 tests annually. D5211 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(a) The laboratory must review and evaluate the results obtained on proficiency testing performed as specified in subpart H of this part. This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) documentation from the American Proficiency Institute (API), the College of American Pathologists (CAP) and an interview with the technical supervisor (TS) on 7/15/2024, the laboratory failed to document the review of PT results in 2023 and 2024. The findings include: 1. A review of PT documents from API for 2023 identified that the laboratory failed to document the review and evaluation of PT results for bacteriology events one (1) and three (3), hematology/coagulation events one (1), two (2) and three (3) and chemistry core events two (2) and three (3). 2. A review of PT documents from CAP for 2024 identified that the laboratory failed to document the review and evaluation of PT results for microbiology event one (1). 3. A review of PT documents from API for 2024 chemistry core event one (1) identified that the laboratory failed to evaluate unacceptable PT results for estradiol samples IA-01, IA-02, IA-03, IA-04 and alanine aminotransferase sample CH-01. 4. An interview with the TS on 7/15/2024 at 9:49 am confirmed the above findings. 5. The laboratory reports performing 85,696 tests annually. D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on a review of proficiency testing (PT) documents from the College of American Pathologists (CAP), the American Proficiency Institute (API) and an interview with the technical supervisor (TS) on 7/15/2024, the laboratory failed to review and evaluate PT scores that were given an artificial score of 100% in 2023 and -- 2 of 4 -- 2024. The findings include: 1. A review of PT documents from CAP for 2023 hematology automatic differential event A identified that the laboratory failed to evaluate results for red cell distribution width (RDW) samples F16 1-5 that were given an artificial score of 100% due to lack of a peer group. 2. A review of PT documents from CAP for 2023 hematology automatic differential event C identified that the laboratory failed to evaluate results for RDW samples F16 11-15 that were given an artificial score of 100% due to lack of a peer group. 3. A review of PT documents from CAP for 2023 semen analysis event A identified that the laboratory failed to evaluate results for anti-sperm antibody sample SEM-07 that was given an artificial score of 100% due to lack of consensus. 4. A review of PT documents from CAP for 2023 semen analysis event B identified that the laboratory failed to evaluate results for anti-sperm antibody sample SEM-18 that was given an artificial score of 100% due to lack of consensus. 5. A review of PT documents from CAP for 2024 semen analysis event A identified that the laboratory failed to evaluate results for anti- sperm antibody sample SEM-08 that was given an artificial score of 100% due to lack of consensus. 6. A review of PT documents from API for 2024 chemistry core event one identified that the laboratory failed to evaluate results for bilirubin samples CH- 02, CH-03 and CH-05 that were given artificial scores of 100% due to result variance. 7. An interview with the TS on 7/15/2024 at 9:50 am confirmed the above findings. 8. The laboratory reports performing 85,696 tests annually. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on a review of calibration records, instrument documents for the Alfa Wassermann Axcel and an interview with the technical supervisor (TS) on 7/15/2024, the laboratory failed to verify the reportable range with at least a minimum value, mid- point value and high value once every six months for chloride, sodium and potassium in 2023 and 2024. The findings include: 1. A review of calibration records and documents for the Alfa Wassermann Axcel identified that the laboratory failed to perform verifications of the reportable range for the analytes chloride, sodium and -- 3 of 4 -- potassium at least every six months in 2023 and 2024. 2. An interview with the TS on 7/15/2024 at 11:31 am confirmed the above finding. 3. The laboratory reports performing 3,992 chloride, sodium and potassium tests annually. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 9, 2022

Survey Type: Standard

Survey Event ID: UGMI11

Deficiency Tags: D5445 D5785

Summary:

Summary Statement of Deficiencies D5445 CONTROL PROCEDURES CFR(s): 493.1256(d)(1)(2)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- (d)(1) Perform control procedures as defined in this section unless otherwise specified in the additional specialty and subspecialty requirements at 493.1261 through 493.1278. (d)(2) For each test system, perform control procedures using the number and frequency specified by the manufacturer or established by the laboratory when they meet or exceed the requirements in paragraph (d)(3) of this section. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on a review of the laboratory's Microscan individualized quality control plan (IQCP), the manufacturer instructions for use (IFU), the laboratory's Microscan quality control (QC) records, and an interview with testing personnel 1 (TP1) on 8/9 /2022, the laboratory failed to perform QC with the frequency and control organisms specified by the manufacturer. The findings include: 1. The laboratory Microscan IQCP states they will follow manufacturers IFU. The manufacturers IFU's are as follows: Positive combo panel type 44 (PC44) new lot/shipment organisms: S. aureus 29213, E. faecalis 29212, S. gallolyticus 49147, M. luteus 49732, S. saprophyticus 49907, S. xylosus 49148, S. pneumoniae 49136, E. raffinosus 49464 and weekly organisms: S. gallolyticus 49147, E. Faecalis 29212 and S. aureus 29213. Negative combo panel type 73 (NUC73) new lot/shipment organisms: E. coli 25922, P. aeruginosa 27853, K. oxytoca 49131, P. vulgaris 49132, P. stuartii 49809, P. putida 49128, S. halitotis 49138, E. faecalis 29212, S. aureus 29213, R. insidiosa 49129, E. coli 35218, K. pneumoniae 700603 and weekly organisms: E. coli 25922, P. aeruginosa 27853, E. coli 35218 and K. pneumoniae 700603. 2. A review of the laboratory Microscan QC records identified that the laboratory failed to perform new lot/shipment QC using the following organisms on PC44 panels: M. luteus 49732, S. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- saprophyticus 49907, S. xylosus 49148, S. pneumoniae 49136, E. raffinosus 49464 and the following organisms on NUC73 panels: K. oxytoca 49131, P. vulgaris 49132, P. stuartii 49809, P. putida 49128, S. halitotis 49138, E. faecalis 29212, S. aureus 29213, R. insidiosa 49129, E. coli 35218, K. pneumoniae 700603. 3. A review of the laboratory Microscan QC records identified that the laboratory failed to perform the required weekly QC for PC44 and NUC73 panels. 4. An interview with the laboratory TP1 on 8/9/2022 at 8:59 confirmed that the laboratory failed to test all required organisms on the two Microscan panels for new lot/shipment and they they failed to perform weekly QC. 5. The laboratory reports performing 20,000 microbiology tests annually. D5785

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 28, 2021

Survey Type: Standard

Survey Event ID: O5XO11

Deficiency Tags: D6013

Summary:

Summary Statement of Deficiencies D6013 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(3)(ii) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(3) Ensure that-- (e)(3)(ii) Verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method; This STANDARD is not met as evidenced by: Based on record review of Estradiol validation, and an interview with the laboratory manager on 01/28/2021, the laboratory director failed to ensure the verification procedures for the analyte Estradiol were adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method. The findings include: 1. A record review of the new analyte validation study for Estradiol revealed that the laboratory director failed to approve the validation prior to testing patient specimens. 2. An interview with the laboratory manager on 01/28/2021 at 11:10 AM confirmed the laboratory director failed to review, sign, and approve the validation study prior to testing patient specimens. 3. The laboratory reports performing 490 Estradiol patient tests from the time Estradiol was validated on August 23, 2019 to the time of the current survey on 01/28/2021. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 24, 2018

Survey Type: Standard

Survey Event ID: 7EKO11

Deficiency Tags: D5221 D5471 D5481 D5791 D6107

Summary:

Summary Statement of Deficiencies D5221 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(d) All proficiency testing evaluation and verification activities must be documented. This STANDARD is not met as evidenced by: Based on proficiency testing (PT) record review and an interview with the laboratory manager, the laboratory failed to document the evaluation of unsatisfactory PT results for the analyte sodium from the American Proficiency Institute (API) program 2017 event 1. Findings: 1. A review of PT results from API chemistry 2017 event 1, revealed the laboratory failed to document the evaluation and

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access