Illume Fertility

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 07D2009676
Address 103 Newtown Rd, Ste 1a, Danbury, CT, 06810
City Danbury
State CT
Zip Code06810
Phone203 750-7434
Lab DirectorMARK LEONDIRES

Citation History (2 surveys)

Survey - March 3, 2020

Survey Type: Standard

Survey Event ID: YODF11

Deficiency Tags: D5421 D5407

Summary:

Summary Statement of Deficiencies D5407 PROCEDURE MANUAL CFR(s): 493.1251(d) Procedures and changes in procedures must be approved, signed, and dated by the current laboratory director before use. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to ensure an approved laboratory procedure was in place prior to performing tests in the specialty of hematology. Findings include: 1. Review of the laboratory's quality control (QC) records on 3/3/2020 for semen analysis (SA) revealed: (a) The laboratory is using proficiency test (PT) materials received from American Association of Bioanalysts (AAB) as QC materials as of 2/3/2020. (b) A hand written note stating, "QC Accubeads out of service 1/31/2020-AAB PT use begin 2/3/2020." 2. Review of laboratory's SA procedure manual (PN-LA-AND-306) on 3/3/2020 revealed accubeads are being used as QC materials for SA test. 3. Staff interview with the laboratory manager on 3/3/2020 at 11:30 AM confirmed: (a) The laboratory switched the QC materials for SA from Accubeads to AAB PT materials effective 2/3/2020. (b) SA-QC procedure is not updated and/or approved by the laboratory director at the time of the inspection on 3/3/2020. (c) Documentation for staff education and/or training with QC procedure update was not available. 4. The laboratory performs 225 SA tests annually. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on record review and staff interview the laboratory failed to demonstrate that it can obtain performance specifications comparable to those established by the manufacturer before introducing an unmodified, FDA-cleared or approved test system. Findings include: 1. Review of the laboratory's validation records for beta human chorionic gonadotropin (b-HCG) test on 3/3/2020 revealed: a. Documentation for verification reportable ranges for b-HCG test not performed. b. The laboratory went live with b-HCG testing on 11/8/2018. c. The above validation data was reviewed and approved by the laboratory director. 2. Staff interview with the laboratory manager (LM) on 3/3/2020 at 9:50 AM confirmed the above findings. The LM further stated he/she is unaware if reportable ranges were verified prior to going live with b-HCG testing. 3. The laboratory performs 8,000 b-HCG tests annually. 4. This is a repeat deficiency. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 23, 2018

Survey Type: Standard

Survey Event ID: 4UR411

Deficiency Tags: D5401 D5291 D5421

Summary:

Summary Statement of Deficiencies D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to ensure an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements. Findings include: 1. Record review of the laboratory's quality incident (QI) documents dated 11/7/17 on 3/23/18 revealed the following incident had occurred: a) A semen sample was obtained from Patient #1 on 11/7/17 for in-vitro fertilization. b) Paper work attached to above sample included copies photo identification (driver's license) from Patient #1 and Patient #2. 2. Record review of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access