Illume Fertility

CLIA Laboratory Citation Details

2
Total Citations
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 07D0973463
Address 761 Main Ave, Ste 200, Norwalk, CT, 06851
City Norwalk
State CT
Zip Code06851
Phone203 750-7434
Lab DirectorMARK LEONDIRES

Citation History (2 surveys)

Survey - September 2, 2025

Survey Type: Standard

Survey Event ID: DX4G11

Deficiency Tags: D2105

Summary:

Summary Statement of Deficiencies D2105 ENDOCRINOLOGY CFR(s): 493.843(e) (e)(1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to document remedial action when unacceptable proficiency testing (PT) scores were obtained for two consecutive PT events in the subspecialty of endocrinology. Findings include: 1. Record review on 09/02/2025 of the 'Centers for Medicare & Medicaid Services (CMS) Casper Report 0155D' revealed the laboratory obtained an unacceptable PT score for the following analyte: 0540 Estradiol, 2025 Event 1 and 2, score: 80%. 2. Record review on 09/02/2025 of the laboratory's proficiency testing 'American Association of Bioanalysts - Medical Laboratory Evaluation (AAB-MLE)' form revealed the following: a. AAB-MLE M1 2025: Endocrinology 1 i. 'Analyte: Estradiol' ii. 'Method: Roche Elecsys' iii. 'Instrument: Roche Cobas 6000, 8000' iv. 'Score: 80' v. 'Specimen: 3' vi. 'Reported Value: *32' vii. 'Grading Range: 13.0 - 24.0' b. AAB-MLE M2 2025: Endocrinology 1 i. 'Analyte: Estradiol' ii. 'Method: Roche Elecsys' iii. 'Instrument: Roche Cobas 6000, 8000' iv. 'Score: 80' v. 'Specimen: 10' vi. 'Reported Value: *28' vii. 'Grading Range: 14.0 - 26.0' 3. Record review on 09/02 /2025 of the laboratory's PT binder revealed lack of documentation of

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 9, 2021

Survey Type: Standard

Survey Event ID: OFOE11

Deficiency Tags: D0000

Summary:

Summary Statement of Deficiencies D0000 The RMACT Laboratory was surveyed and found in compliance with CLIA Regulations 42 CFR, Part 493, as a result of a recertification survey performed on December 9, 2021. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access