Iowa Clinic Laboratory, The

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 16D0383307
Address 1215 Pleasant Street, Suite 206, Des Moines, IA, 50309
City Des Moines
State IA
Zip Code50309
Phone515 875-9874
Lab DirectorCURTIS MCCARTY

Citation History (1 survey)

Survey - August 19, 2025

Survey Type: Standard

Survey Event ID: 1LC811

Deficiency Tags: D5217 D2000 D5421

Summary:

Summary Statement of Deficiencies D2000 ENROLLMENT AND TESTING OF SAMPLES CFR(s): 493.801 Each laboratory must enroll in a proficiency testing (PT) program that meets the criteria in subpart I of this part and is approved by HHS. The laboratory must enroll in an approved program or programs for each of the specialties and subspecialties for which it seeks certification. The laboratory must test the samples in the same manner as patients' specimens. For laboratories subject to 42 CFR part 493 published on March 14, 1990 (55 FR 9538) prior to September 1, 1992, the rules of this subpart are effective on September 1, 1992. For all other laboratories, the rules of this subpart are effective January 1, 1994. This CONDITION is not met as evidenced by: Based on review of American Proficiency Institute (API) proficiency testing records, the laboratory's test list, observations made during the survey, and confirmed by interview with the Practice Manager at 1:55 pm on 08/19/2025, the laboratory failed to enroll in an HHS approved proficiency testing program for the analyte, troponin-I, for one out of one year from 01/01/2025- 08/19/2025. The findings include: 1. The laboratory's test list indicated the laboratory performs troponin-I testing on the Triage MeterPro test system. 2. A tour of the laboratory confirmed the presence of the Triage MeterPro test system and troponin-I test cartridges. 3. At the time of the survey, the Practice Manager confirmed the laboratory did not enroll in proficiency testing for the analyte, troponin-I, in 2024. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on review of the laboratory's test list, American Proficiency Institute (API) proficiency testing records, observations made during the survey, and confirmed by interview with the Practice Manager at 1:55 pm on 08/19/2025, the laboratory failed to verify the accuracy of d-dimer testing performed on the Triage MeterPro test system twice annually for one out of one time period from 01/01/2025- 08/19/2025. The findings include: 1. The laboratory's test list indicated the laboratory performs d- dimer testing on the Triage MeterPro test system. 2. A tour of the laboratory confirmed the presence of the Triage MeterPro test system and d-dimer test cartridges. 3. At the time of the survey, the Practice Manager confirmed the laboratory did not enroll in proficiency testing or perform twice annual accuracy testing for d-dimer testing by another method from 01/01/2025- 08/19/2025. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) (b) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (b)(1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (b)(1)(i) (A) Accuracy. (b)(1)(i)(B) Precision. (b)(1)(i)(C) Reportable range of test results for the test system. (b)(1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of performance specification records and confirmed by interview with Technical Consultant #1 (TC #1) at 3:15 pm on 08/19/2025, the laboratory failed to verify the performance specifications of precision and reportable range prior to testing and reporting patient specimens on the Triage MeterPro test system for two out of two analytes. The findings include: 1. The laboratory began using the Triage MeterPro test system to perform troponin-I and d-dimer patient testing in December 2024. 2. Review of the Triage MeterPro verification of performance specification records indicated the laboratory failed to verify precision and reportable range for troponin-I and d-dimer testing. 3. At the time of the survey, TC #1 confirmed that the laboratory failed to have documentation of verification of the performance specifications of precision and reportable range for troponin-I and d-dimer testing. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access