J Matthew Knight Md Pa

CLIA Laboratory Citation Details

2
Total Citations
8
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 10D2232915
Address 1901 Lee Road, Winter Park, FL, 32789
City Winter Park
State FL
Zip Code32789
Phone(407) 992-0660

Citation History (2 surveys)

Survey - March 19, 2026

Survey Type: Standard

Survey Event ID: Y9L511

Deficiency Tags: D5413 D6120 D0000 D3011 D5217

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Forefront Dermatology SC Corp dba Knight Dermatology a Forefront Dermatology Practice on March 19, 2026. The laboratory was surveyed under 42 CFR Part 493 CLIA requirements. Standard deficiencies cited are as follows: D3011 FACILITIES CFR(s): 493.1101(d) Safety procedures must be established, accessible, and observed to ensure protection from physical, chemical, biochemical, and electrical hazards, and biohazardous materials. This STANDARD is not met as evidenced by: Based on review of the Safety Data Sheets (SDS) and interview, the laboratory failed to ensure protection from chemical hazards used in their Hematoxylin and Eosin (H&E) stain from 01/18/2024 to 09/19/2026. Findings Included: 1. Review of the SDS for Avantik Acid Alcohol, 1% noted, "Do not dispose of in the drain" 2. Review of the Avantik Reagent Alcohol 95% and Avantik Reagent Alcohol, 100% noted, "Do not allow into any sewer, on the ground, or into any body of water. Avoid release into the environment." During an interview on 03/19/2026 at 9:20 AM, the Mohs technician revealed she dumped the Acidic Acid and the 95% and 100% Reagent Alcohol down the drain. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on review of the procedure manual, record review, and interview, the laboratory failed to verify accuracy of the reading and interpretation (proficiency testing) of the Hematoxylin and Eosin (H&E) stain for two (Laboratory Director, Testing Personnel D) of four (Laboratory Director, Testing Personnel B - D) Mohs surgeons who performed Mohs surgical procedures in 2024. Findings included: 1. Review of the policy titled Quality Assessment Program - Mohs Laboratory, And dated by the Laboratory Director on 01/01/2026 noted, for proficiency testing "three cases Mohs peer reviewed semi-annually." 2, Review of the Mohs Patient Assession logs showed the Laboratory Director performed Mohs surgical procedures form 03/19 /2024 to 11/4/2024. 3. Review of the Mohs Patient Assession logs showed Testing Personnel D performed Mohs surgical procedures from 10/16/2024 to 11/13/2024. 4. Review of the proficiency testing records revealed there were no records available for review for the Laboratory Director and Testing Personnel D for 2024. 5. During an interview on 03/19/2026 at 11:10 AM, the Practice Manager stated there was no peer review done in 2024 for Laboratory Director. 6. During an interview on 03/19/2026 at 11:35 AM, the Practice Manager stated there was no peer review done in 2024 for Testing Personnel D. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of the procedure manual, record review, and interview, the laboratory failed to document the room temperature for 75 of 121 days that Mohs surgical procedures were performed in 2025. Findings included: 1. Review of the procedure titled, Lab Thermometer Maintenance, signed and dated by the Laboratory Director on 01/01/2026 noted, "Document that thermometer check has been completed by initialing Log 722-B Room Temp/ Humidity Chart." 2. Review of the Room Temp/Humidity log noted, "The room temperature and humidity will be checked at the beginning of each work day, when cryostat in use." 3. Review of the Room Temp/Humidity log showed the room temperatures were not recoreded on the following days in 2025: January - 6, 7, 8, 9, 10, 20, 21, 22, 23, 24 February - 3, 4, 5, 6, 7, 17, 18, 19, 20, 21 March - 3, 4, 5, 6, 7, 19, 20, 21, 24, 25, 26, 31 April - 1, 2, 3, 4, 14, 15, 16 17, 18, 20, 21 May - 6, 7, 19, 20, 21, 22, 23 June - 2, 3, 4, 5, 6, 16 17, 18, 30 July - 1, 2, 3, 14, 15, 16 17, 18, 28, 29, 30 August - 11, 12, 13, 14, 15 4. Review of the Clinical Laboratory Amendments Application for Certification signed and dated by the Laboratory Director on 03/16/2026, reported a total estimated annual test volume of 1,000. 5. During an interview on 03/19/2026 at 10:17 PM, the Practice Manager acknowledged room temperatures were not recorded. D6120 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(7)(8) -- 2 of 3 -- (b)(7) Identifying training needs and assuring that each individual performing tests receives regular in-service training and education appropriate for the type and complexity of the laboratory services performed; (b)(8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: Based on review of the procedure manual, review of personnel records, and interview, the Technical Supervisor (Laboratory Director) failed to document competency evaluation for one (Testing Personnel B) of two (Laboratory Director and Testing Personnel B) Mohs Surgeons in 2024 and 2025, and failed to document the initial training / competency evaluation for two (Testing Personnel C - D) of four Mohs Surgeons (Laboratory Director and Testing Personnel B - D) in 2024. Findings included: 1. Review of the procedure titled, Personnel Competency Testing, signed and dated by the Laboratory Director on 01/01/2026 noted, "Laboratory compliance requires training/competency to be completed initially, 6 months after the start date and annually thereafter." 2. Review of the personnel records for Testing Personnel B revealed there was no documentation of annual competency evaluations on the Mohs Surgeon for 2024 and 2025. 3. Review of the personnel records for Testing Personnel C and D revealed there was no documentation of initial training / competency evaluation for the Mohs Surgeons for 2024. 4. During an interview on 03/99/2026 at 12:05 PM, the Practice Manager stated she did not think there was any competency evaluation on the Mohs Surgeons. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 4, 2022

Survey Type: Standard

Survey Event ID: 1GTT11

Deficiency Tags: D0000 D5805 D5609

Summary:

Summary Statement of Deficiencies D0000 An initial certification survey was conducted on April 4, 2022. J Matthew Knight MD PA clinical laboratory was not in compliance with 42 CFR 493, requirements for clinical laboratories. D5609 HISTOPATHOLOGY CFR(s): 493.1273(e)(f) (e) The laboratory must use acceptable terminology of a recognized system of disease nomenclature in reporting results. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to document the open dates for reagents used in their Hematoxylin & Eosin (H & E) stains from 10/26/2021 to 04/04/2022. Findings: Review of the laboratory's "Chemical Log" showed in the "Date Opened" column listed "N/A" for the dates the following reagents were opened: 100% Reagent Alcohol lot numbers 092323 and 133489, Vintage Bluing lot number 130229, Focus 1% Acid Alcohol lot number 127906, Xylene Substitute (XS-3) lot number 128724, and 95% Reagent Alcohol lot number 130608. During an interview on 04/04/2011 at 10:30 PM, the Administrator acknowledged not all the dates the reagents were opened were recorded on the log. D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to provide all required information for the Mohs surgical reports for three of three sampled patients, (#1, #2, #3). Findings: On 04/04/2022 at 10:40 AM, the laboratory provided a copy of the Visit Note for the Mohs surgical procedures to patients if requested. Review of Visit Notes showed the name of the laboratory as it appeared on the CLIA (Clinical Laboratory Improvement Amendments) certificate was missing from the report. On 04 /04/2022 at 10:58 AM, the Administrator said they gave a copy of the Visit Note to patients if they requested it, and the name of the laboratory as it appeared on the CLIA certificate was not on the Visit Notes. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access