CLIA Laboratory Citation Details
44D0921688
Survey Type: Special
Survey Event ID: UU1B11
Deficiency Tags: D2016 D2096
Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on a review of the Centers for Medicare and Medicaid Casper Report 155 (CMS 155) and the laboratory's College of American Pathologists (CAP) proficiency testing (PT) evaluation reports, the laboratory failed to maintain satisfactory performance for two consecutive PT events for the lactate dehydrogenase (LDH) analyte resulting in initial unsuccessful PT occurrence for the LDH analyte (Refer to D2096). D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is unsuccessful performance. This STANDARD is not met as evidenced by: Based on a desk review of the CMS 155 and the laboratory's 2024 CAP PT evaluation reports, the laboratory failed to maintain satisfactory performance for two consecutive PT events for the LDH analyte. The findings include: 1. A review of the CMS 155 report revealed LDH analyte scores of 0% for 2024 events one and two. 2. A review of the CAP PT evaluation reports for 2024 events one and two revealed LDH analyte scores of 0%. -- 2 of 2 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Standard
Survey Event ID: OXGQ11
Deficiency Tags: D5209 D5543 D5217 D5415 D5417 D5451 D5471 D5775
Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of the laboratory procedure manual, personnel records, and staff interview, the laboratory failed to follow the procedure for annual competency assessments in 2021 and 2022 for six of seven established testing personnel. The findings include: 1. Review of the laboratory procedure manual revealed that annual competency assessments would be performed on established personnel. 2. Review of testing personnel records revealed that annual competencies were not performed in 2021 for six of seven established testing personnel (testing personnel numbers two, three, four, five, six and seven). No competency assessment had been performed in 2022 as of the date of the survey (02/16/2022). 3. Interview with the technical consultant on 02/16/2022 at approximately 5:30pm confirmed the laboratory failed to follow its' own policy for annual competency assessment in 2021 and 2022. D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on review of the laboratory's proficiency testing records and staff interview, the laboratory failed to verify the accuracy of Estradiol and Parathyroid Hormone (PTH) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 5 -- tests twice a year in 2021. The findings include: 1. Review of the laboratory's proficiency testing records revealed the laboratory participated in proficiency testing to verify the accuracy of Estradiol and PTH in 2021. The laboratory received two events per year for the analytes. The laboratory failed 2021 event one for Estradiol with a score of 33% and PTH with a score of 0%. No other records were available that verified the accuracy of the Estradiol and PTH twice a year in 2021. 2. Interview with the technical consultant on 02/16/2022 at approximately 5:30pm confirmed the laboratory failed to verify the accuracy of Estradiol and PTH when it failed 2021 event one, and did not perform any other type of alternative assessment in 2021. D5415 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(c) Reagents, solutions, culture media, control materials, calibration materials, and other supplies, as appropriate, must be labeled to indicate the following: (1) Identity and when significant, titer, strength or concentration. (2) Storage requirements. (3) Preparation and expiration dates. (4) Other pertinent information required for proper use. This STANDARD is not met as evidenced by: Based on observation of the laboratory and staff interview, the laboratory failed to label chemistry controls and calibrators with open dates and corrected expiration dates in 2022. The findings include: 1. Observation of the laboratory on 02/15/2022 at approximately 10am revealed multiple vials of chemistry controls and calibrators in use that were not labeled with either open date or corrected expiration date. The quick reference guide in the control box indicated shortened stability of products after they were opened. None of the products were labeled. 2. Interview with the technical consultant on 02/16/2022 at approximately 5:30pm confirmed controls and calibrators were not labeled with open dates or corrected expiration dates. The products have shortened stability after opening. The controls and calibrators were in use for chemistry tests performed on the Vitros 5600. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of patient test records and staff interview, the laboratory failed to ensure controls were not used past their expiration date from 02/10/2022 to 02/15/2022 with 30 patients reported. The findings include: 1. Observation of the laboratory on 02/15/2022 at approximately 10am revealed expired controls in use for performing quality control for C-Reactive Protein on the Ortho Vitros 5600, Lot numbers Q8625 and R8626, expiration date of 02/09/2022. 2. Review of patient number 13-049-019 revealed C-Reactive Protein results reported on 02/10/2022 when controls were expired. 3. Review of patient data logs revealed that 30 patient C-Reactive Protein results were reported when the expired controls were in use. 4. Interview with the technical consultant on 02/15/2022 at approximately 5:30 pm confirmed the survey findings. -- 2 of 5 -- D5451 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(iii)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Test procedures producing graded or titered results include a negative control material and a control material with graded or titered reactivity, respectively; 493.1256 (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of patient test results, laboratory records, laboratory procedure and staff interview, the laboratory failed to include a titered control for the rheumatoid arthritis factor (RA) when reporting positive patients with a titered result in 2020. The findings include: 1. Observation of the laboratory on 02/15/2022 at approximately 10am revealed the Rheumajet RF kit in use for patient testing for rheumatoid arthritis factor (RA). 2. Review of patient number 13-266-031 revealed RA reported as "RA Positive, RA Titer 64" on 09/08 /2020. 3. Review of the quality control for the RA test for 09/08/2020 revealed no titered control was included. 4. Review of the laboratory procedure for RA revealed titered control is not included as part of the quality control protocol when patient results are reported as a titer. 5. Interview with the technical consultant on 02/16/22 at approximately 5:30pm confirmed the survey findings. D5471 CONTROL PROCEDURES CFR(s): 493.1256(e)(1)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e)(i) Check each batch (prepared in-house), lot number (commercially prepared) and shipment of reagents, disks, stains, antisera, (except those specifically referenced in 493.1261 (a)(3)) and identification systems (systems using two or more substrates or two or more reagents, or a combination) when prepared or opened for positive and negative reactivity, as well as graded reactivity, if applicable. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of patient test reports and laboratory records, and staff interview, the laboratory failed to have a process in place to ensure dermatophyte testing medium (DTM) fungal culture lot numbers were traceable to DTM lot number quality control (QC) records in 2022. The findings include: 1. Review of patient number 11-314-009 revealed fungal culture qualitative results reported on 01/05/2022. 2. Review of laboratory records revealed no indication of the lot number of DTM used to perform the testing on patient 11-314-009. There was no method to track or determine if quality control had been performed on the medium used on patient 11-314-009. 3. Interview with the technical consultant on 02/15/2022 at approximately 10am revealed the following: DTM is ordered for their satellite dermatology clinic. The DTM is sent directly to the satellite location from the vendor. After the patient specimen is placed into the DTM, the test is sent to the main lab. The satellite clinic also sends vials from each box to the main lab for QC testing, however, there was no -- 3 of 5 -- way to trace the lot number of the dermatophyte testing medium used on the patient to the QC records. The technical consultant confirmed there was no way to determine that QC had been performed for the DTM lot number used on the patient. D5543 HEMATOLOGY CFR(s): 493.1269(a)(d) (a) For manual cell counts performed using a hemocytometer-- (a)(1) One control material must be tested each 8 hours of operation; and (a)(2) Patient specimens and control materials must be tested in duplicate. (d) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of the laboratory procedure manual, patient test reports, request for laboratory quality control records, and interview with the technical consultant, the laboratory failed to perform quality control for sperm count performed on the hemacytometer in 2020, 2021, and 2022. The findings include: 1. Review of the laboratory procedure manual revealed testing for sperm count is performed using a hemacytometer. The laboratory procedure did not address quality control requirements. 2. Review of patient test reports revealed semen analysis for sperm count for patient ID number 09-256-030 performed on 08/04/2020, patient ID number 21-134-022 performed on 05/14/2021, and patient ID number 19-252-008 performed on 01/13/2022. 3. Request on 02/22/2022 at approximately 10:30 am for hemacytometer quality control records revealed no quality control is performed on the hemacytometer for the quantitative sperm counts. 4. Interview with the technical consultant on 02/16/2022 at approximately 5:30pm confirmed the laboratory does not perform quality control on the hemacytometer for quantitative sperm count. D5775 COMPARISON OF TEST RESULTS CFR(s): 493.1281(a)(c) (a) If a laboratory performs the same test using different methodologies or instruments, or performs the same test at multiple testing sites, the laboratory must have a system that twice a year evaluates and defines the relationship between test results using the different methodologies, instruments, or testing sites. (c) The laboratory must document all test result comparison activities. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of laboratory documentation, patient test results, document request and staff interview, the laboratory failed to perform comparison between the two Vitros 5600 chemistry instruments in 2020, 2021, and 2022. The findings include: 1. Observation of the laboratory on 02/15/2022 at approximately 10am revealed two Ortho Vitros 5600 chemistry instruments in use for patient testing (J56002716 and J56003437). 2. Review of documentation provided by the laboratory revealed that both instruments are used to perform the certain identical patient tests. Tests that are performed on both chemistry instruments includes comprehensive metabolic panel, lipid panel, basic metabolic panel, hepatic function panel, thyroid stimulating hormone, free thyroxine, vitamin D, ferritin, magnesium, and B-type natriuretic peptide, and urine chemistry for microalbumin and creatinine. 3. Review of patient test reports revealed comprehensive metabolic panel performed on patient 17-013-042 on Vitros 1 (J56002716) on 05/04/2021 and comprehensive -- 4 of 5 -- metabolic panel performed on patient 09-254-123 on the Vitros 2 (J56003437) instrument on the same date. 4. Request on 02/15/2022 at 2pm for instrument to instrument comparison studies between the two instruments revealed no comparison studies were available. 5. Interview with the technical consultant on 02/16/2022 at approximately 5:30pm confirmed the laboratory did not perform comparisons twice a year between the two Vitros 5600 chemistry instruments in 2020, 2021 or 2022. -- 5 of 5 --
Get full access to the detailed deficiency summary for this facility
Survey Type: Standard
Survey Event ID: VQ9811
Deficiency Tags: D5217 D5439 D5791
Summary Statement of Deficiencies D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on observation of the microbiology laboratory, review of patient number one test report, proficiency testing records and interview with the laboratory supervisor, the laboratory failed to verify the accuracy of dermatophyte testing medium (DTM) fungal cultures in 2017 and 2018. The findings include: 1. Observation of the microbiology laboratory on September 10, 2018 at 10:00 am revealed DTM in use for performing patient fungal cultures. 2. Review of patient number one final test report revealed patient reporting for DTM on August 3, 2018. 3. Review of the laboratory's proficiency testing records for 2017 and 2018 revealed no records were available for twice a year verification of accuracy of DTM fungal culture in 2017 and 2018. 4. Interview with the laboratory supervisor on September 10, 2018 at 3:30 pm confirmed the laboratory did not verify the accuracy of DTM fungal cultures in 2017 and 2018. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of the manufacturer calibrator package insert, the manufacturer operator manual, calibration verification documents and interview with testing personnel number 2, the laboratory failed to verify the calibration of the glycated hemoglobin (hgb A1c) analyte on the Tosoh G8 instrument using at least a minimal, mid-point and maximum value near the upper limit of the range at least every 6 months in 2017 and 2018 with patients performed and reported. The findings include: 1. Observation of the laboratory on September 10, 2018 at 10:45 am revealed the Tosoh G8 instrument (serial #14676805) in use for patient testing for hgb A1c. 2. Review of the manufacturer hgb A1c calibrator package insert for lot ZS7001 revealed that calibration is performed using only 2 calibrators with calibrator values of 5.7% and 10.7%. 3. Review of the manufacturer operator manual for the Tosoh G8 instrument revealed a measuring range of 4.0% - 16.9% and calibration performed using only 2 calibrator levels for the hbg A1c analyte. 4. Review of calibration verification documents for the Hemoglobin A1c analyte revealed calibration verification was not performed every 6 months in 2017 or 2018. 5. Interview with testing personnel number one on September 11, 2018 at 10:00 am confirmed the laboratory performs patient testing for HGB A1c on the Tosoh G8 instrument, calibrates using 2 calibration points, uses the manufacturer measuring range, and failed to verify the calibration of the Tosoh G8 instrument every 6 months in 2017 and 2018 with patients performed and reported. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on observation of the laboratory, review of the prothrombin time (PT) calculated mean patient normal records, and interview with testing personnel number one, the laboratory failed to ensure the quality assessment (QA) process included the correct mean patient normal PT was correctly entered into the instrument in 2018. The findings include: 1. Observation of the laboratory on September 11, 2018 at 2:00 pm revealed the Sysmex CA620 in use for patient testing for PT. The mean patient normal PT entered into the instrument setting used for calculating the international normalized ratio (INR) was 10.3. 2. Review of the records for calculated mean patient -- 2 of 3 -- normal PT for lot #549720 (current lot) revealed a mean patient normal PT value of 10.4. 3. Interview with testing personnel number one on September 11, 2018 at 2:20 pm confirmed the laboratory's QA was ineffective when the incorrect mean patient normal PT was entered into the coagulation instrument in 2018. There is no QA process to ensure the mean is entered into the instrument correctly. -- 3 of 3 --
Get full access to the detailed deficiency summary for this facility