James Valley Community Health Center

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 43D2031570
Address 1000 18th St Sw Suite 27, Huron, SD, 57350
City Huron
State SD
Zip Code57350
Phone(605) 554-1015

Citation History (2 surveys)

Survey - November 18, 2021

Survey Type: Standard

Survey Event ID: 4WZV11

Deficiency Tags: D0000 D2006 D5215

Summary:

Summary Statement of Deficiencies D0000 A recertification survey for compliance with 42 CFR Part 493, Requirements for Laboratories, was conducted on 11/18/21. The James Valley Community Health Center laboratory was found not in compliance with the following requirements: D2006 and D5215. D2006 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b) The laboratory must examine or test, as applicable, the proficiency testing samples it receives from the proficiency testing program in the same manner as it tests patient specimens. This testing must be conducted in conformance with paragraph (b)(4) of this section. If the laboratory's patient specimen testing procedures would normally require reflex, distributive, or confirmatory testing at another laboratory, the laboratory should test the proficiency testing sample as it would a patient specimen up until the point it would refer a patient specimen to a second laboratory for any form of further testing. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to process proficiency testing (PT) samples in the same manner as patient specimens for four of eight American Proficiency Institute (API) PT events reviewed (API 2020 Chemistry Core third PT event and 2021 Chemistry Core first, second, and third PT events). Failure to dilute and reanalyze PT samples in the same manner as patient specimens did not ensure the accuracy of patient specimens that were diluted and reanalyzed. Findings include: 1. Review of the API PT event records revealed: *API 2020 Chemistry Core third PT event, human chorionic gonadotropin (HCG) (serum quantitative) HCG-12 and HCG-14 samples were reported as >1,000 mili-international units/milliter (mIU /ml). *API 2021 Chemistry Core first PT event, HCG (serum quantitative) HCG-03 and HCG-04 samples were reported as >1,000 mIU/ml. *API 2021 Chemistry Core second PT event HCG (serum quantitative) HCG-08 sample was reported as >1,000 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- mIU/ml. *API 2021 Chemistry Core third PT event, HCG (serum quantitative) HCG- 11, HCG-12, HCG-13,and HCG-15 samples were reported as >1,000 mIU/ml. Review of several random patient quantitative HCG quantitative reports revealed patient specimens were routinely diluted and reanalyzed to obtain accurate test results when initial values above the 1,000 mIU/ml analyzer's upper reporting limit were detected. Review of the laboratory's Proficiency Testing policy, signed by the laboratory director, revealed "General Guidelines- Analyze PT specimens according to patient protocols at all times throughout the process." Interview on 11/18/21 at 10:20 a.m. with laboratory personnel A revealed: *She confirmed patient specimens for quantitative HCG testing that resulted in an initial analyzer result of >1,000 mIU/ml were routinely diluted and reanalyzed to provide accurate results above the 1,000 mIU /ml analyzer's upper reporting limit. *She confirmed PT samples were not diluted if an initial analyzer result of >1,000 mIU/ml was reported. The >1,000 mIU/ml result was reported on the PT report without further analysis. *She stated, "A previous technical consultant had told them not to dilute PT specimens." D5215 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(b)(2) The laboratory must verify the accuracy of any analyte, specialty or subspecialty assigned a proficiency testing score that does not reflect laboratory test performance (that is, when the proficiency testing program does not obtain the agreement required for scoring as specified in subpart I of this part, or the laboratory receives a zero score for nonparticipation, or late return or results). This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory failed to review proficiency testing (PT) results to ensure their accuracy for six of six "not graded" American Proficiency Institute (API) PT samples reviewed (API 2021 Chemistry Core first event CH-02, and HCG-04; and API Chemistry Core third event HCG-11, HCG-12, HCG-13, and HCG-15). Findings include: 1. Review of the API PT records for 2021 revealed: *There had been no documentation the following samples had been reviewed for their accuracy. These samples had not been graded due to lack of consensus. *API Chemistry Core first PT event CH-02 sample's alanine transaminase result and HCG-04 sample's human chorionic gonadotropin (HCG) result. *API Chemistry Core third PT event HCG-11, HCG-12, HCG-13, and HCG-15 samples' HCG results. Review of the Proficiency Testing Checklist for both of the above PT events revealed "Were 'not graded' test results evaluated by laboratory to identify potential problems" was marked yes on both checklists. Review of the laboratory's Proficiency Testing policy, signed by the laboratory director, revealed- "Assessment of the Proficiency Testing Report- Evaluate all ungraded responses and perform a self- evaluation to verify the accuracy of analytes that are not graded or that are scored 100% due to non-consensus or lack of peer group. Compare your actual performance against the stated target and allowable range of the PT specimen as defined in the participant summary available from the PT provider. Document any

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - April 24, 2019

Survey Type: Standard

Survey Event ID: 3MJM11

Deficiency Tags: D0000 D5447

Summary:

Summary Statement of Deficiencies D0000 A recertification survey for compliance with 42 CFR Part 493, Requirements for Laboratories, was conducted on 4/24/19. The James Valley Community Health Center laboratory was found not in compliance with the following requirement: D5447. D5447 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(i)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each quantitative procedure, include two control materials of different concentrations; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the Triage analyzer quality control (QC) records and interview with the laboratory manager, the laboratory failed to perform two levels of controls or establish an equivalent quality control method to verify the accuracy of three of three non-waived test methods (D-Dimer, troponin, and creatinine kinase MB fraction [CKMB]) performed on the Triage analyzer each day patient testing was performed. Findings include: 1. Review of theTriage analyser QC records from 11/1/18 through 4 /24/19 revealed: *QC results had not been documented for the D-Dimer test method on eleven days (4/15/19, 4/9/19, 3/27/19, 1/31/19, 1/24/19, 1/14/19, 12/19/18, 12/18 /18, 12/13/18, 12/4/18, and 11/21/18). Patient test results had been reported to the provider on those days. *QC results had not been documented for the Troponin and CK MB test methods on seven days (4/9/19, 1/24/19, 1/14/19, 12/19/18, 12/18/18, 11 /14/18, and 11/2/18). Patient test results had been reported to the provider on those days. Interview on 4/24/19 at 4:30 pm with the laboratory manager revealed current laboratory practice was to perform QC on a monthly basis and whenever a new test kit was put into use. He was not aware QC was required each day patient testing was performed unless an equivalent control method had been established. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access