Citation History (3 surveys)

Survey - February 8, 2023

Survey Type: Standard

Survey Event ID: WCW611

Deficiency Tags: D5473

Summary:

Summary Statement of Deficiencies D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on surveyor observation, review of laboratory documents, patient test records, and confirmed in an interview, the laboratory failed to document Hematoxylin and Eosin (H&E) staining materials for intended reactivity each day of patient testing for 10 random patients reviewed in February and June of 2022. The findings include: 1. In the laboratory walk-through on 2/8/2023 at 10:45 hours, the surveyor noted an H&E staining station used for patient testing. 2. Review of the laboratory policies and the laboratory vertical section specimen log did not include instructions or documentation of tissue stain acceptability for H&E. Surveyor queried if the information could be found in a separate place, and none was provided. 3. Review of random patient final reports in February and June have the following 10 patients on days where there was no documented H&E stain acceptability: February 2022: 4 patients Procedure Date: 2/16/2022 Path Number: 22-0569 Procedure Date: 2/17/2022 Path Number: 22-0621 Path Number: 22-0618 Procedure Date: 2/21/2022 Path Number: 22-0648 June 2022: 6 patients Procedure Date: 6/20/2022 Path Number: 22- 2397 Procedure Date: 6/21/2022 Path Number: 22-2433 Path Number: 22-2439 Procedure Date: 6/22/2022 Path Number: 22-2440 Path Number: 22-2444 Procedure Date: 6/23/2022 Path Number: 22-2461 4. In an interview on 2/8/2023 at 11:45 hours, in the office, the histo-tech confirmed that the H&E stain acceptability had not been documented for the above days where patients had been tested. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 2, 2021

Survey Type: Standard

Survey Event ID: XYFP11

Deficiency Tags: D0000 D5217 D5413 D5417 D5805 D0000 D5217 D5413 D5417 D5805

Summary:

Summary Statement of Deficiencies D0000 The facility was found to be in compliance with applicable Conditions of Participation in the CLIA program, and recertification is recommended. . D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: . Based on review of laboratory policy, laboratory records, and confirmed in interview, the laboratory failed to verify the accuracy of potassium hydroxinde (KOH) for two of two years (2019 and 2020). 1. Review of the laboratory 'Quality Assurance Procedures', subsection KOH states: "At least twice annually, the lab director will verify the accuracy of KOH by peer review. The lab Tech will keep a KOH log in the lab and the Lab Director will monitor it quarterly." 2. Based on review of the laboratory quality assurance logs, the laboratory failed to verify the accuracy of the PPM test KOH twice annually in 2019 and 2020. 3. In an interview at 13:10 hours on 12/2/2021, the laboratory personnel confirmed the above stating that they just don't perform that many KOH's. Key: KOH - potassium hydroxide PPM - Provider performed microscopy . D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: . I. Based on surveyor observation, review of laboratory environmental logs, and confirmed in interview, the laboratory failed to have a system in place to monitor the temperature for four of four reagents stored for histopathology. 1. During the tour of the facilities at 09:10 hours on 12/2/2021 the surveyor observed the following reagents in a flammable cabinet, in a closet, in a patient exam room. Eosin Y Hematoxylin 7211 Clear-Rite 3 PolarStat - Frozen Embedding Material 2. Based on review of laboratory environmental records the laboratory failed to have a temperature monitor in place for storage area for above reagents. 3. In an interview at 09:15 hours on 12/2/2021, in the patient exam room, the laboratory personnel confirmed that there was no temperature monitor in place for the storage of the above reagents. II. Based on review of the instrument instruction manual, laboratory environmental logs, and confirmed in interview, the laboratory failed to monitor humidity for the Leica CM1510S Cryostat, for eleven of eleven months reviewed. 1. Review of the instruction manual for the Leica CM1510S Cryostat (V1.4) Section 4. 'Setup', subsection 4.1 'Installation site requirements' lists the following humidity installations requirements that must be met. "relative humidity max. 60%" With an informational note stating, "high room temperature and excessive air humidity at the installation site affect the cooling capacity of the cryostat." 2. Based on review of the laboratory's 'Temperature Monitor Log - Refrigerator, Freezer, Cryostat' for January through November 2021 the laboratory failed to monitor the humidity for the Leica CM1510S Cyrostat for eleven of the eleven months reviewed. 3. In an interview at 11:30 hours on 12/2/2021 with laboratory personnel at confirmed that the laboratory did not record the relative humidity for the Leica CM1510S Cryostat. . D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: . Based on surveyor observation, review of patient records, and confirmed in interview, the laboratory failed to ensure expired potassium hydroxide (KOH) reagent was not in use in patient testing for seven of seven patients tested between June 2020 and August 2021. 1. During a tour of the facility with the primary laboratory personnel at 09:10 hour on 12/2/2021 surveyor observed the following expired reagent next to the providers microscope. HealthLink KOH 10% - Lot 1914004 EXP 2020-05-20 2. Review of patient records for June 2020, September 2020, June 2021, and August 2021 lists the following 7 patients tested: June 2020 - 2 Patients 6/25/2020 - 5860 6/30/2020 - 9456 September 2020 - 2 Patients 9/2/2020 - 42909 9/2/2020 - 65256 June 2021 - 2 Patients 6/3/2021 - See Patient KOH Worksheet 1 6/4/2021 - 63544 August 2021 - 1 Patient 8/1/2021 - See Patient KOH Worksheet 2 3. During an interview at 09:10 hours on 12/2/2021 with the laboratory personnel confirmed that the expired 10% KOH reagent located next to the provider's microscope was the one used for the PPM KOH test, and that no other non-expired KOH was available for testing. Key: KOH - potassium hydroxide PPM: Provider performed microscopy . -- 2 of 3 -- D5805 TEST REPORT CFR(s): 493.1291(c) The test report must indicate the following: (c)(1) For positive patient identification, either the patient's name and identification number, or a unique patient identifier and identification number. (c)(2) The name and address of the laboratory location where the test was performed. (c)(3) The test report date. (c)(4) The test performed. (c)(5) Specimen source, when appropriate. (c)(6) The test result and, if applicable, the units of measurement or interpretation, or both. (c)(7) Any information regarding the condition and disposition of specimens that do not meet the laboratory's criteria for acceptability. This STANDARD is not met as evidenced by: . Based on review patient test records and confirmed in interview, the laboratory failed to have the name and address of the laboratory location where the test was performed, for one of one PPM testing performed; KOH. 1. Based on review of five PPM patient test reports for KOH, the laboratory failed to include the name and address of the laboratory location where the test was performed. 2. In an interview at 11:00 hours on 12/2/2021 with the practice manager confirmed that the provided patient records were the only place in which the PPM test KOH was reported. . -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - June 6, 2019

Survey Type: Standard

Survey Event ID: MJSF11

Deficiency Tags: D6120 D6120 D5219

Summary:

Summary Statement of Deficiencies D5219 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(2) At least twice annually, the laboratory must verify the accuracy of any test or procedure listed in subpart I of this part for which compatible proficiency testing samples are not offered by a CMS-approved proficiency testing program. This STANDARD is not met as evidenced by: . I. Based on review of laboratory documentation for 2017, 2018 and 2019 and staff interview, the laboratory failed to verify the accuracy of frozen section examinations at least twice annually. Findings: a. Review of laboratory Pathology Frozen Section logs for 2017, 2018 and 2019 showed a log sheet indicating accuracy verification by peer review for five cases in 2018. No records were found for 2017 or 2019. b. In an interview at the site on 06-06-2019, the clinic manager confirmed that no peer review documentation for 2017 and 2018 was present or could be offered at the time of the survey. II. Based on surveyor observation, review of laboratory documentation for 2017, 2018 and 2019 and staff interview, the laboratory failed to verify the accuracy of potassium hydroxide (KOH) mycology and mineral oil scabies preps performed at the site. Findings: a. In the course of the survey it was noted that a nurse practitioner (testing person 2-CMS form 209) was employed by the practice. In an interview at the site on 06-06-2019, when asked if he performed any testing, the clinic manager stated that testing person 2 did occasionally perform KOH or mineral oil prep examinations on patient specimens. b. Documentation of semiannual accuracy verification for this testing was requested. No such documentation was available or could be offered during the survey. . D6120 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(7)(8) (7) The technical supervisor is responsible for identifying training needs and assuring Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- that each individual performing tests receives regular in-service training and education appropriate for the type and complexity of the laboratory services performed; (8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: . Based on review of laboratory documentation and staff interview, the laboratory technical supervisor (CMS form 209) failed to evaluate the competency of the testing person performing KOH and mineral oil prep examinations at the site. Findings: 1. In the course of the survey it was revealed that testing person 2 had been performing KOH and mineral oil prep examinations on patients at the site. In an interview at the site on 06-06-2019, the clinic manager estimated that testing person 2 performed an average of 40 such tests a year. Refer to D5219. 2. Competency verification documentation for testing person 2 was requested. No such documentation was available or could be offered during the survey. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access