Jefferson Dermatology Associates

CLIA Laboratory Citation Details

3
Total Citations
14
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 39D0696343
Address 33 S 9th Street, Suite 740, Philadelphia, PA, 19107
City Philadelphia
State PA
Zip Code19107

Citation History (3 surveys)

Survey - January 16, 2025

Survey Type: Standard

Survey Event ID: VTVZ11

Deficiency Tags: D5429 D5429

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) (a)(1) Maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on observation of the laboratory, lack of maintenance records and interview with the histotechnician (HT), the laboratory failed to perform and document the maintenance and function checks as defined by the manufacturer for 1 of 1 Fisher Hygro thermometer/humidity monitor and 1 of 1 McKesson Room Thermometer used for monitoring room temperature and humidity in the histopathology laboratory from 01/30/2023 to the day of the survey. Findings include: 1. On the day of the survey, 01 /16/2025 at 09:50 am, observation of the laboratory revealed the following thermometers used for room temperature and humidity monitoring in the histopathology laboratory were due for maintenance: - 1 of 1 Fisher hygro thermometer clock (s/n# 32714) due 03/02/2023 -1 of 1 Mckesson Room Thermometer due 12/2024. 2. The laboratory failed to provide maintenance/functions checks records for the Fisher hygro thermometer clock and the McKesson Room Thermometer from 03/30/2023 to 01/16/2025. 3. The laboratory performed 1380 histopathology examinations in 2024 (CMS 116, estimated annual volume). 4. The HT confirmed the findings above on 01/16/2025 at 09:50 am. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - January 30, 2023

Survey Type: Standard

Survey Event ID: EO1D11

Deficiency Tags: D5209 D5413 D5413 D6120 D5209 D5601 D5601 D6120

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of the competency assessment records and interview with the histotechnician (HT), the laboratory failed to establish written policies and procedures to assess the competency of 1 of 2 clinical consultants (CC) for their supervisory responsibilities from 12/21/2020 to the date of the survey. Findings Include: 1. On the day of the survey, 01/30/2023 at 09:50 am, the laboratory could not provide a written procedure to assess the competency of 1 of 2 CC (CMS 209 CC# 2) for their supervisory responsibilities from 12/21/2020 to 01/30/2023. 2. The laboratory could not provide competency assessment records for 1 of 2 CC (CMS 209 CC #2) for their supervisory responsibilities in 2021 and 2022. 3. The HT confirmed the findings above on 01/30/2023 around 11:30 am. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- This STANDARD is not met as evidenced by: Based on review of the laboratory's temperature records, lack of documentation, and interview with the histotechnician (HT), the laboratory failed to record the relative humidity and internal cryostat temperature to ensure operating conditions were met for 1 of 1 Advanitk QS11 Cryostats from October 2021 to the date of the survey. Findings Include: 1. On the day of the survey, 01/30/2023 at 10:06 am, the laboratory failed to provide documentation for the relative humidity and internal cryostat temperature of 1 of 1 Advantik QS11 Cryostats to ensure operating conditions were met from October 2021 to January 2023. 2. The TJUS Mohs Dermatology Lab Policy and Procedure Manual: Center City states, "Temperature and humidity is checked and recorded at the beginning of the surgical day, before any procedures." 3. The laboratory performed 1487 MOHS micrographic surgery slide examinations in 2022 (CMS 116 annual volume). 4. The HT confirmed the findings above on 01/30/2023 around 11:30 am. D5601 HISTOPATHOLOGY CFR(s): 493.1273(a)(f) (a) As specified in 493.1256(e)(3), fluorescent and immunohistochemical stains must be checked for positive and negative reactivity each time of use. For all other differential or special stains, a control slide of known reactivity must be stained with each patient slide or group of patient slides. Reactions of the control slide with each special stain must be documented. (f) The laboratory must document all control procedures performed, as specified in this section. This STANDARD is not met as evidenced by: Based on review of the laboratory's quality control (QC) staining records and interview with the histotechnician (HT), the laboratory failed to document negative and positive staining reactivity each time of use for 1 of 1 immunohistochemical (IHC) stains used for MOHS micrographic surgery (MOHS) slide examinations from 12/20/2020 to the date of the survey. Findings include: 1. On the day of the survey, 01 /30/2023 at 10:20 am, review of the laboratory's stain QC log revealed that a control for negative and positive reactivity was not documented each time of use for 1 of 1 IHC stains (Mart-1) used for MOHS slide examinations from 12/20/2020 to 01/30 /2023. 2. The HT confirmed the finding above on 01/30/2023 at 11:30 am. D6120 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(7)(8) (7) The technical supervisor is responsible for identifying training needs and assuring that each individual performing tests receives regular in-service training and education appropriate for the type and complexity of the laboratory services performed; (8) Evaluating the competency of all testing personnel and assuring that the staff maintain their competency to perform test procedures and report test results promptly, accurately and proficiently. This STANDARD is not met as evidenced by: Based on review of the laboratory competency assessment records and interview with the histotechnician (HT), the technical supervisor (TS) failed to evaluate the annual competency assessment for 1 of 2 testing personnel (TP) who performed MOHS -- 2 of 3 -- micrographic surgery slides examinations from 12/21/2020 to the day of the survey. Findings include: 1. On the day of survey, 01/30/2023 at 09:50 am, the laboratory could not provide competency assessment records for 1 of 2 TP (CMS 209 TP #2) who performed MOHS micrographic surgery slide examinations from 12/21/2020 to 01/30/2023. 2. The laboratory performed 1487 MOHS micrographic surgery slide examinations in 2022 (CMS 116 annual volume). 3. The HT confirmed the finding above on 01/30/2023 around 11:30 am. -- 3 of 3 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 21, 2020

Survey Type: Standard

Survey Event ID: 19JE11

Deficiency Tags: D5209 D6094 D5209 D6094

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on review of the competency records and interview with the testing personnel (TP) #3 and the laboratory director (LD), the laboratory failed to establish written policies and procedures to assess the competency for 1 of 2 Clinical Consultants (CC) and 1 of 2 TP who analyzed Mohs microscopic examinations in 2018, 2019 and 2020. Findings Include: 1. On the day of survey, 12/21/2020, the laboratory could not provide a written procedure to assess the competency of 1 of 2 CC (CC#2) for their consultant responsibilities in 2018, 2019 and 2020. 2. The laboratory could not provide competency assessment records for CC#2, for their consultant responsibilities in 2018, 2019 and 2020. 3. The laboratory could not provide competency assessment records for TP#2, who analyzed Mohs microscopic examinations in 2018, 2019 and 2020. 4. The LD and TP#3 confirmed the findings above on 12/21/2020 around 9:10 am. D6094 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Based on review of the laboratory records and interview of the Testing Personnel (TP) #3 and the laboratory director (LD), the LD failed to maintain the laboratory's Quality Assessment (QA) programs in 2018, 2019 and 2020. Findings Include: 1. The Lab Policy and Procedure Manual, Quality Assessment Plan states, "The mohs staff and director will discuss and evaluate the plan and make changes where its needed at the mohs meeting biannually". 2. On the day of survey, 12/21/2020, the laboratory could not provide QA meeting minutes performed biannual in 2018, 2019 and 2020. 3. The LD and TP#3 confirmed the findings above on 12/21/2020 at 9:20 am. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access