Jeffrey L Stein Md Pa

CLIA Laboratory Citation Details

4
Total Citations
10
Total Deficiencyies
8
Unique D-Tags
CMS Certification Number 10D0925340
Address 9291 Glades Rd Ste 306, Boca Raton, FL, 33434
City Boca Raton
State FL
Zip Code33434
Phone561 483-5500
Lab DirectorJEFFREY STEIN

Citation History (4 surveys)

Survey - April 18, 2025

Survey Type: Standard

Survey Event ID: EBTH11

Deficiency Tags: D0000 D5413 D5217

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Jeffrey L Stein MD PA on March 17, 2025 to April 18, 2025. The laboratory is not in compliance with 42 CFR Part 493, Requirements for Laboratories. The following is a description of the standard level deficiencies: D5217 EVALUATION OF PROFICIENCY TESTING PERFORMANCE CFR(s): 493.1236(c)(1) At least twice annually, the laboratory must verify the accuracy of any test or procedure it performs that is not included in subpart I of this part. This STANDARD is not met as evidenced by: Based on record review and interviews, the laboratory failed to verify twice annual accuracy for Urinary Beta-Trace Protein (UIBC) testing in 2024. Findings Included: 1. Review of 2024 American Proficiency Institute Chemistry -Core revealed the following: 2nd event in 2024 for Urinary Beta-Trace Protein was 60%. 3rd event in 2024 for Urinary Beta-Trace Protein was 0%. There was no documentation of a rerun for Urinary Beta-Trace Protein failures. 2. Review of Policy: "Proficiency testing" signed by laboratory director read, "

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 21, 2022

Survey Type: Standard

Survey Event ID: 18O511

Deficiency Tags: D2009 D5791 D0000 D5439

Summary:

Summary Statement of Deficiencies D0000 A recertification survey conducted, 12/21/2022 found the JEFFREY L STEIN MD PA clinical laboratory not in compliance with 42 CFR Part 493, Requirements for Laboratories. D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on record review and staff interview, the laboratory failed to have attestations signed by testing person (TP) and laboratory director (LD) for five out of six events for Hematology/Coagulation specialty, six out six events of Chemistry Core and four out of four events of Chemistry Miscellaneous and failed to have the LD to sign attestation for one out of six events in Hematology/Coagulation specialty for the last 2 years. Findings include: -Review of American Proficiency Institute (API) proficiency testing (PT) records for years 2021 and 2022 revealed that a) The laboratory failed to have attestation signed by the TP and LD in the following events: 1- Hematology /Coagulation first and third event 2021, first, second and third event 2022. 2- Chemistry Core for the first, second and third event of 2021 and 2022. 3- Chemistry Miscellaneous first and second event 2021 and 2022. b) The Laboratory failed to have attestation signed by LD for second event of 2021 for Hematology/Coagulation specialty. During an interview on 12/21/2022 at 1:30 PM, the laboratory consultant confirmed that the laboratory failed to have a signed attestation for the events of reference. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on record review and interview with Laboratory Consultant (LC), the laboratory failed to have documentation of the calibration verification for the Cell- Dyn 1800 complete blood analyzer at least every 6 months from 01/01/2021 to 12/21 /2022. Findings include: -Review of the Cell-Dyn 1800 Analyzer revealed that the laboratory performed calibration on 10/28/2022. No other calibration records found. During an interview on 12/21/2022 at 12:00 PM, the LC explained that they cannot print from the CBC instrument and she was not able to provide any other documentation of previous calibrations verification performed in 2021 and first half of 2022. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on record review and interview, the laboratory Quality Assessment (QA) failed to identify and correct the deficiency of incomplete documentation of required maintenance for the Cobas e411 and Cobas Integra 400 Analyzer in 2021 and 2022. The QA failed to correct the deficiency of not having records for calibration verification in 2021 and 2022. The QA failed to ensure the laboratory had records of the Annual Preventive Maintenance for the Cobas e411, Cell-Dyn 1800 and Cobas Integra analyzers for 2021 and 2022. The QA failed to identify the missing Room Temperature and Room Humidity record for March 2022. Findings include: -Review of Monthly QA policy checklist revealed that the Laboratory will review that all required temperatures will be taken. The QA checklist failed to include verification of -- 2 of 3 -- instruments maintenance. -Review of maintenance logs for Cobas Integra 400 analyzer revealed that the monthly logs for February, May, July and September of 2021 failed to have the monthly maintenance action (clean waste box fitting and clean ISE tower manually) documented. No correction documented in QA. -Review of monthly maintenance log for Cobas e411 analyzer revealed that the following logs failed to have every 2 month maintenance action (replace pinch valve tubing) documented: Jan, May and November 2021 and March, May, July and September of 2022. No

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 27, 2020

Survey Type: Standard

Survey Event ID: S9V211

Deficiency Tags: D0000 D2121

Summary:

Summary Statement of Deficiencies D0000 An announced CLIA recertification survey was conducted at Jeffrey L Stein MD PA on October 27, 2020. The laboratory is not in compliance with 42 CFR Part 493, Requirements for Laboratories. The following is a description of the standard level deficiencies: D2121 HEMATOLOGY CFR(s): 493.851(a) Failure to attain a score of at least 80 percent of acceptable responses for each analyte in each testing event is unsatisfactory analyte performance for the testing event. This STANDARD is not met as evidenced by: Based on review of American Proficiency Institute (API) proficiency testing results and interview with the Technical Consultant, the laboratory failed to score at least 80% for Hematocrit in 1 out of 6 (3rd testing event 2018 through 2nd testing event in 2020) testing events reviewed in the specialty of Hematology. Findings Included: Review of API proficiency testing results in the 2nd testing event in 2020 revealed a score of 20 % for Hematocrit. During an interview on October 27, 2020 at 10:30 AM, the Technical Consultant confirmed the proficiency testing failure. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 19, 2018

Survey Type: Standard

Survey Event ID: EYJQ11

Deficiency Tags: D2007

Summary:

Summary Statement of Deficiencies D2007 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The samples must be examined or tested with the laboratory's regular patient workload by personnel who routinely perform the testing in the laboratory, using the laboratory's routine methods This STANDARD is not met as evidenced by: Based on review of CMS 209 Laboratory Personnel Report, review of American Proficiency Institute (API) proficiency testing (PT) records and interview with Laboratory Consultant (LC) the laboratory failed to have all testing people (TP) rotate through the testing of PT for the hematology specialty for 2 out of 2 years (2017 -2018) reviewed. Findings include: Review of CMS 209 signed and dated by the Laboratory Director (LD) had 2 testing personnel listed (TPA and TPB). Review of API PT for Hematology found that TPA was the only person who performed PT in 2017-2018. During an interview on 12/19/2018 at 11:30 AM the LC confirmed that TPA was the only TP that performed PT for the years of reference. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access