John D Sprandio Md Laboratory

CLIA Laboratory Citation Details

3
Total Citations
18
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 39D0858508
Address 30 Lawrence Road, Suite 201, Broomall, PA, 19008
City Broomall
State PA
Zip Code19008
Phone(610) 492-5900

Citation History (3 surveys)

Survey - April 18, 2024

Survey Type: Standard

Survey Event ID: 4WNE11

Deficiency Tags: D5423 D5429 D5423 D5429

Summary:

Summary Statement of Deficiencies D5423 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(2) Each laboratory that modifies an FDA-cleared or approved test system, or introduces a test system not subject to FDA clearance or approval (including methods developed in-house and standardized methods such as text book procedures), or uses a test system in which performance specifications are not provided by the manufacturer must, before reporting patient test results, establish for each test system the performance specifications for the following performance characteristics, as applicable: (2)(i) Accuracy. (2)(ii) Precision. (2)(iii) Analytical sensitivity. (2)(iv) Analytical specificity to include interfering substances. (2)(v) Reportable range of test results for the test system. (2)(vi) Reference intervals (normal values). (2)(vii) Any other performance characteristic required for test performance. This STANDARD is not met as evidenced by: Based on lack of documentation and interview with testing personnel (TP) #1 the laboratory failed to establish performance specifications before reporting patient test results when modifying an FDA-cleared/approved test system for platelet (PLT) counts performed on the Sysmex XN L complete blood count analyzer from 10/12 /2022 to 04/18/2024. Findings include: 1. Sysmex XN L manufacturer's instruction states "Whole blood should be collected in K2 or K3EDTA anticoagulant and peritoneal, pleural, and synovial fluids in K2EDTA anticoagulant to prevent clotting of fluid." 2. On the day of the survey, 04/18/2024 at 11:22 am, the laboratory could not provide documentation for the performance specifications established when performing PLT counts using sodium citrate anticoagulant (blue top tube) for 1 of 1 the Sysmex XN L complete blood count analyzer from 10/12/2022 to 04/18/2024. 3. TP #1 confirmed the findings above on 04/18/2024 at 12:30 pm. D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on observation of the laboratory, lack of documentation, and interview with testing personnel (TP) #1, the laboratory failed to perform and document the maintenance/ function checks for 1 of 1 thermometer used to monitor room temperature used for storage of hematology reagents from 08/21/2020 to the day of survey. Findings Include: 1. On the day of survey, 04/18/2024 at 12:00 pm, the laboratory could not provide maintenance/function check records for the following 1 of 1 thermometer used to monitor room temperature used for storage of hematology reagents from 10/12/2022 to 04/18/2024: - TFA Dostmann : exp: 08/21/2020 2. The following hematology reagents were found to be stored in the laboratory at RT. - Sysmex SLS Sulfolyser (Storage temperature requirements 1-30 degrees Celsius) - 1 of 1 - Sysmex WDF Lysercell (Storage temperature requirements 2-35 degrees Celsius) - 2 of 2 3. The TP #1 confirmed the findings above on 04/18/2024 at 12:30 pm. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 12, 2022

Survey Type: Standard

Survey Event ID: HKVU11

Deficiency Tags: D5421 D5473 D6033 D6035 D6055 D5421 D5473 D6033 D6035 D6055

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of the Sysmex XNL-430 analyzer validation records, lack of documentation, and interview with testing personnel #1 (TP), the laboratory failed to establish criteria for acceptable performance specifications for 12 of 12 analytes performed on the Sysmex XNL-430 analyzer from 08/15/2022 to the date of survey. Findings include: 1. On the day of survey, 10/12/2022 at 11:10 am, review of the Sysmex XNL-430 analyzer validation records revealed that the validation performed on 08/15/2022 did not include the laboratory's acceptable criteria for performance specifications for precision, accuracy, reportable ranges, and reference intervals/range (normal values) for the following analytes: - White Blood Count (WBC) - Red Blood Count (RBC) - Hemoglobin (HGB) - Hematocrit (HCT) - Mean Corpuscular Volume (MCV) - Mean Corpuscular Hemoglobin (MCH) - Mean Corpuscular Hemoglobin Concentration (MCHC) - Platelet (PLT) -Mean Platelet Volume (MPV) -Red Blood Cell Distribution Weight (RDW) - Neutrophils (NEU) - Lymphocytes (LYM) 2. The laboratory could not provide documentation verifying that the manufacturer's reference intervals are appropriate for the laboratory's patient population. 3. The laboratory could not provide a procedure for new method/test validation. 4. The laboratory director did not review and approve all validation studies performed on the Sysmex XNL-430 before reporting patient results. 5. The laboratory performed 6666 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- hematology examinations from 9/19/2022 to 10/12/2022. 6. TP #1 confirmed the findings above on 10/12/2022 around 12:00 pm. D5473 CONTROL PROCEDURES CFR(s): 493.1256(e)(2)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (2) Each day of use (unless otherwise specified in this subpart), test staining materials for intended reactivity to ensure predictable staining characteristics. Control materials for both positive and negative reactivity must be included, as appropriate. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on review of the laboratory's manual differential quality control (QC) log, procedure manual, and interview with testing personnel #1 (TP), the laboratory failed to establish criteria for intended reactivity to ensure acceptable staining characteristics for manual differentials stained using Quik Diff Stain from 08/20/2020 to the date of survey. Findings: 1. On the day of survey, 10/12/2022 at 11:35 am, review of manual differential QC logs and the laboratory's Reportable Phrasing for Smears procedure revealed that the laboratory did not establish or document criteria for intended reactivity for acceptable staining characteristics of manual differentials stained using Quik Diff Stain from 08/20/2020 to 10/12/2022. 2. TP #1 confirmed the findings above on 10/12/2022 around 12:00 pm. D6033 TECHNICAL CONSULTANT-MODERATE COMPEXITY CFR(s): 493.1409 The laboratory must have a technical consultant who meets the qualification requirements of 493.1411 of this subpart and provides technical oversight in accordance with 493.1413 of this subpart. This CONDITION is not met as evidenced by: Based on review of personnel qualification records and interview with Testing Personnel #1 (TP), the laboratory failed to have a technical consultant who meets the qualification requirements (493.1411) for moderate complexity hematology testing from 08/20/2020 to the date of survey. Refer to D6035. D6035 TECHNICAL CONSULTANT QUALIFICATIONS CFR(s): 493.1411 (a) The technical consultant must be qualified and must possess a current license issued by the State in which the laboratory is located, if such licensing is required. (b) The technical consultant must-- (b)(1)(i) Be a doctor of medicine or doctor of osteopathy licensed to practice medicine or osteopathy in the State in which the laboratory is located; and (b)(1)(ii) Be certified in anatomic or clinical pathology, or both, by the American Board of Pathology or the American Osteopathic Board of Pathology or possess qualifications that are equivalent to those required for such certification; or (b)(2)(i) Be a doctor of medicine, doctor of osteopathy, or doctor of podiatric medicine licensed to practice medicine, osteopathy, or podiatry in the State in which the laboratory is located; and (b)(2)(ii) Have at least one year of laboratory training or experience, or both in non-waived testing, in the designated specialty or -- 2 of 4 -- subspecialty areas of service for which the technical consultant is responsible (for example, physicians certified either in hematology or hematology and medical oncology by the American Board of Internal Medicine are qualified to serve as the technical consultant in hematology); or (b)(3)(i) Hold an earned doctoral or master's degree in a chemical, physical, biological or clinical laboratory science or medical technology from an accredited institution; and (b)(3)(ii) Have at least one year of laboratory training or experience, or both in non-waived testing, in the designated specialty or subspecialty areas of service for which the technical consultant is responsible; or (b)(4)(i) Have earned a bachelor's degree in a chemical, physical or biological science or medical technology from an accredited institution; and (b)(4)(ii) Have at least 2 years of laboratory training or experience, or both in non-waived testing, in the designated specialty or subspecialty areas of service for which the technical consultant is responsible. Note: The technical consultant requirements for "laboratory training or experience, or both" in each specialty or subspecialty may be acquired concurrently in more than one of the specialties or subspecialties of service, excluding waived tests. For example, an individual who has a bachelor's degree in biology and additionally has documentation of 2 years of work experience performing tests of moderate complexity in all specialties and subspecialties of service, would be qualified as a technical consultant in a laboratory performing moderate complexity testing in all specialties and subspecialties of service. This STANDARD is not met as evidenced by: Based on review of personnel qualification records, competency assessment (CA) records and interview with testing personnel #1 (TP), the laboratory failed to ensure that 1 of 1 laboratory staff who performed the responsibilities of a technical consultant (TC) from 8/20/2020 to the date of survey met the required TC qualifications under C. F.R 493.1411. Findings include: 1. Review of the CMS 209 personnel form, signed by the laboratory director (LD) on 10/12/2022, lists the LD as the only TC. 2. Further review of CA records and interview with TP#1 on 10/12/2022 at 09:30 am, revealed that TP#1 performed the duties of a TC listed under C.F.R. 493.1413 from 08/20/2020 to 10/12/2022. 3. Review of personnel credentials provided on the date of suvey, 10/12 /2022 at 11:00 am, revealed TP #1 has a high school diploma, which does not meet the minimal educational qualifications (493.1411) to perform technical consultant responsibilities for moderate complexity testing in hematology . 4. TP#1 confirmed the findings above on 10/12/2022 around 12:00 pm. D6055 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(9) The technical consultant is responsible for evaluating and documenting the performance of individuals responsible for moderate complexity testing whenever test methodology or instrumentation changes. The individual's performance must be reevaluated to include the use of the new test methodology or instrumentation prior to reporting patient test results. This STANDARD is not met as evidenced by: Based on review of the laboratory's competency assessment (CA) records and interview with testing personnel #1 (TP), the Technical Consultant (TC) failed to reevaluate and document the performance of 13 of 13 TP responsible for moderate complexity hematology testing performed on new instrumentation (Sysmex XNL- 430) prior to reporting patient test results from 09/19/2022 to the date of survey. -- 3 of 4 -- Findings include: 1. At the time of survey, 10/12/2022 at 11:00 am, the laboratory could not provide documentation of the reevaluation of performance for 13 of 13 testing personnel performing complete blood counts (CBC) on new instrumentation (Sysmex XNL-430) implemented by the laboratory prior to reporting patient test results from 09/19/2022 to 10/12/2022. 2. TP #1 confirmed the above findings on 10 /12/2022 around 12:00 pm. -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 20, 2020

Survey Type: Standard

Survey Event ID: 1GDJ11

Deficiency Tags: D5403 D5437 D5403 D5437

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access