Survey - January 10, 2018

Survey Type: Standard

Survey Event ID: 0H9E11

Deficiency Tags: D1001 D5291 D6000 D6021 D1001 D5291 D6000 D6021

Summary:

Summary Statement of Deficiencies D1001 CERTIFICATE OF WAIVER TESTS CFR(s): 493.15(e) Laboratories eligible for a certificate of waiver must-- (1) Follow manufacturers' instructions for performing the test; and (2) Meet the requirements in subpart B, Certificate of Waiver, of this part. This STANDARD is not met as evidenced by: Based on the surveyor's review of the laboratory's Quality Control (QC) records and interview with the laboratory supervisor and the laboratory administrator, the laboratory failed to follow the manufacturer's instructions for performing external positive and negative controls with each new lot of Henry Schein Influenza A&B kit, each new lot of Henry Schein Rapid Strep kit and with each new lot of Binax RSV kit. FINDINGS: 1. On 1/10/2018 at approximately 11:00 AM the laboratory supervisor and the laboratory administrator confirmed surveyor's findings that although the laboratory documented the lot numbers, expiration dates and the received dates, there were no records of external positive and negative controls for each new lot of Henry Schein Influenza A&B, each new lot of Henry Schein Rapid Strep and with each new lot of Binax RSV from September 2017 through the survey date. 2. Approximately 60 patient specimens were tested and reported for Influenza A&B, RSV and for Rapid Strep during the above time frame. D5291 GENERAL LABORATORY SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1239(a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and, when indicated, correct problems identified in the general laboratory systems requirements specified at 493.1231 through 493.1236. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on the surveyor's review of the laboratory's Quality Assessment (QA) polices /procedures and an interview with and confirmed by the laboratory supervisor and the laboratory administrator, the laboratory failed to follow the laboratory's written QA policy and perform general laboratory systems QA reviews yearly for bacteriology testing in calendar years 2016 and 2017. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: Based on surveyor's findings and interview with the laboratory supervisor and the laboratory administrator, the laboratory director failed to provide overall management of the laboratory. The laboratory director failed to ensure that the laboratory: 1. maintained the

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access