Kootenai Health Post Falls

CLIA Laboratory Citation Details

2
Total Citations
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 13D1081769
Address 1300 E Mullan Ave, Post Falls, ID, 83854
City Post Falls
State ID
Zip Code83854
Phone(208) 625-5630

Citation History (2 surveys)

Survey - February 24, 2025

Survey Type: Standard

Survey Event ID: TWJK11

Deficiency Tags: D5209

Summary:

Summary Statement of Deficiencies D5209 PERSONNEL COMPETENCY ASSESSMENT POLICIES CFR(s): 493.1235 As specified in the personnel requirements in subpart M, the laboratory must establish and follow written policies and procedures to assess employee and, if applicable, consultant competency. This STANDARD is not met as evidenced by: Based on a review of the Centers for Medicare and Medicaid Services (CMS) 209 personnel form, laboratory procedures, training and competency assessment records and an interview with the technical consultant on 2/24/2025, the laboratory failed to follow written policies and procedures to assess testing personnel competency in 2024. The findings include: 1. The CMS 209 identified three (3) testing personnel (TP) performing moderate complexity testing. 2. A review of laboratory procedures identified that the laboratory established policies and procedures to assess TP initial training, semiannual and annual competency. 3. A review of training and competency assessment records identified that the laboratory failed to have six month competency assessments for three (3) of three (3) TP for the Abbott Alinity in 2024. 4. An interview with the TC on 2/24/2025 at 1:50 pm confirmed the above finding. 5. The laboratory reports performing 104,189 chemistry tests annually. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - March 21, 2023

Survey Type: Standard

Survey Event ID: 740B11

Deficiency Tags: D5429

Summary:

Summary Statement of Deficiencies D5429 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(1) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document maintenance as defined by the manufacturer and with at least the frequency specified by the manufacturer. This STANDARD is not met as evidenced by: Based on a review of maintenance records for the Roche Cobas C311 and an interview with the technical supervisor on 3/21/2023, the laboratory failed to perform instrument maintenance as required by the manufacturer. The findings include: 1. A review of maintenance records for the Roche Cobas C311 identified that the laboratory failed to complete quarterly maintenance which included replacing the ISE pinch valve tubing and replacing the ISE sipper tubing in April 2022, July 2022, October 2022 and January 2023. 2. An interview with the technical supervisor on 3/21 /2023 at 2:09 pm confirmed that quarterly maintenance had not been performed. 3. The laboratory reports performing 101,045 chemistry tests on the Roche Cobas C311 annually. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access