Lab Cl Centro De Certificaciones Medicas Region

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 40D1016052
Address Calle Vallejo Esq Garcia Moreno, Rio Piedras, PR, 00925
City Rio Piedras
State PR
Zip Code00925
Phone(787) 250-1330

Citation History (2 surveys)

Survey - June 12, 2024

Survey Type: Standard

Survey Event ID: I0FY11

Deficiency Tags: D5413 D2009 D0000

Summary:

Summary Statement of Deficiencies D0000 The Centers for Medicare & Medicaid Services (CMS) Survey Branch federal surveyors conducted an announced CLIA recertification survey at LAB CL CENTRO DE CERTIFICACIONES MEDICAS REGION on June 12, 2024. The laboratory was surveyed under 42 CFR part 493 CLIA requirements. The following standard level deficiencies were found during the announced routine CLIA recertification survey on June 12, 2024. D2009 TESTING OF PROFICIENCY TESTING SAMPLES CFR(s): 493.801(b)(1) The individual testing or examining the samples and the laboratory director must attest to the routine integration of the samples into the patient workload using the laboratory's routine methods. This STANDARD is not met as evidenced by: Based on the review of the Department of Health (DOH) of Puerto Rico (PR) Public Health Laboratories - Proficiency Testing (PT) Service Program records and interview with the technical consultant (TC), the laboratory failed to have the testing personnel (TP) attest to the examination of the PR PT programs samples for six of six rapid plasma reagin (RPR) testing events from 2022 to 2024. Findings include: 1. On the day of survey, June 12, 2024, review of the PR PT records revealed the following six of six RPR PT attestation documents were only signed by the TP: Events #2 and #3 in 2022. Events #1, #2 and #3 in 2023. Event #1 in 2024. 2. On CMS form 209, the TC is also listed as TP#1. 3. On June 12, 2024, the TC confirmed the findings above and corrected the deficiency onsite at 11:30 am. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) The laboratory must define criteria for those conditions that are essential for proper Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (1) Water quality. (2) Temperature. (3) Humidity. (4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: 42956 Based on observation, a review of temperature records, and an interview with the Laboratory Director (LD), it was determined that the laboratory failed to monitor and document the storage room temperature. Findings: 1. During the survey on June 12, 2024, at approximately 9:30 AM, it was observed that a storage room contained 12 packs of Greiner Bio-One Vacuette Red Tops tubes, which require a storage temperature of 425C (4077F). 2. Review of temperature records indicated that no monitoring or recording of temperatures was conducted for the storage room. 3. In an interview with the LD on June 12, 2024, at 9:45 AM, it was confirmed that the laboratory does not monitor or document the temperature of the storage room. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 23, 2023

Survey Type: Standard

Survey Event ID: JS6011

Deficiency Tags: D0000 D6051

Summary:

Summary Statement of Deficiencies D0000 The Centers for Medicare & Medicaid Services (CMS) New York (NY) Clinical Laboratory Improvement Amendments of 1988 (CLIA) Branch Location federal surveyor conducted an announced virtual CLIA recertification survey for LAB CL CENTRO DE CERTIFICACIONES MEDICAS REGION on February 23, 2023. Documents received were reviewed from February 17, 2023 to February 23, 2023. The laboratory was surveyed under 42 CFR part 493 CLIA requirements. The following deficiency was found during the announced routine CLIA recertification survey performed on February 23, 2023. D6051 TECHNICAL CONSULTANT RESPONSIBILITIES CFR(s): 493.1413(b)(8)(v) The procedures for evaluation of the competency of the staff must include, but are not limited to assessment of test performance through testing previously analyzed specimens, internal blind testing samples or external proficiency testing samples. This STANDARD is not met as evidenced by: Based on review the Puerto Rico (PR) Department of Health (DOH) Proficiency Testing (PT) Program records, and interview with the laboratory director (LD), technical consultant (TC) and administrative personnel, the laboratory failed to evaluate the assessment of 1 of 2 testing personnel (TP) for their performance of rapid plasma reagin (RPR) testing perform in 2021 and 2022. Finding Include: 1. On February 17, 2023, a virtual review of the PR DOH PT records from 2021 and 2022 revealed, 1 of 2 TP (TP#1) signed the attestations forms. 2. During there virtual survey (February 23, 2023 at 8:50 am), the laboratory could not provide TP#2's evaluations for their assessment of RPR test performance through testing previously analyzed specimens, internal blind testing samples or external PT in 2021 and 2022. 3. The LD and TC confirmed on February 13, 2023 around 8:55 am, that TP#2 was not evaluated for their performed of RPR testing in 2021 and 2022. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access