Lab Clinico Gordo

CLIA Laboratory Citation Details

2
Total Citations
13
Total Deficiencyies
7
Unique D-Tags
CMS Certification Number 40D0673285
Address 71 Carazo St, Guaynabo, PR, 00969
City Guaynabo
State PR
Zip Code00969
Phone(787) 720-3643

Citation History (2 surveys)

Survey - August 24, 2023

Survey Type: Standard

Survey Event ID: MDCD11

Deficiency Tags: D5431 D5431 D6097 D6097

Summary:

Summary Statement of Deficiencies D5431 MAINTENANCE AND FUNCTION CHECKS CFR(s): 493.1254(a)(2) For unmodified manufacturer's equipment, instruments, or test systems, the laboratory must perform and document function checks as defined by the manufacturer and with at least the frequency specified by the manufacturer. Function checks must be within the manufacturer's established limits before patient testing is conducted. This STANDARD is not met as evidenced by: Based on Hematology quality control records, backgrounds logs and interview with the laboratory supervisor on August 24, 2023 at 10:50 AM; it was determined that the laboratory failed to take any

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - October 5, 2021

Survey Type: Standard

Survey Event ID: XPBF11

Deficiency Tags: D5421 D5783 D6093 D6093 D5449 D5421 D5783 D5405 D5449

Summary:

Summary Statement of Deficiencies D5405 PROCEDURE MANUAL CFR(s): 493.1251(c) Manufacturer's test system instructions or operator manuals may be used, when applicable, to meet the requirements of paragraphs (b)(1) through (b)(12) of this section. Any of the items under paragraphs (b)(1) through (b)(12) of this section not provided by the manufacturer must be provided by the laboratory. This STANDARD is not met as evidenced by: Based on Immuno Card Mycoplasma manufacturer's instructions, Mycoplasma testing records and laboratory director interview on October 5, 2021 at 1:54 PM, it was determined that the laboratory failed to follow the manufacturer's instruction when 31 out of 31 patient's specimens were tested for Mycoplasma by Immuno Card Meridian method from August 4, 2021 to September 29, 2021. The findings include: 1. The manufacturer's instruction establishes to perform the test procedures at room temperature from 22 to 25 C. 2. On October 5, 2021 at 1:54 PM, the Mycoplasma testing records showed that the laboratory did not monitor nor record the room temperature when patient's specimens were tested for Mycoplasma by Immuno Card Meridian method from August 4, 2021 to September 29, 2021 3. The laboratory director confirmed on October 5, 2021 at 1:54 PM, that the laboratory did not follow the manufacture's instructions for the temperature of processing. 4. The laboratory processed and reported 31 out of 31 patients specimens for mycoplasma test by Immuno Card Meridian method from August 4, 2021 to September 29, 2021. D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 3 -- manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of validation records for Vitamin D performed by the Dimension system and laboratory director interview on October 5, 2021 at 1:34 PM, it was determined that the laboratory failed to verify that the manufacturer's reference intervals (established normal values) were appropriate for the laboratory's patient population. The findings include: a.During review of records on October 5, 2021 the Dimension system validation records showed that the laboratory performed the validation procedures for Vitamin D test on November 24, 2020. However, the laboratory did not verify that the manufacturer's Vitamin D test reference intervals (established normal values) are appropriate for the laboratory's patient population before reporting patient results on February 10, 2021. b.The Laboratory director confirmed on October 5, 2021 at 1:34 PM, that the laboratory did not verify that the manufacturer's Vitamin D test reference intervals (established normal values) before reporting patients results. c.The laboratory processed and reported 1,559 patients specimens for Vitamin D from February 10, 2021 to October 5,2021. D5449 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(ii)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each qualitative procedure, include a negative and positive control material; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on General Immunology (COVID-19 IgM/IgG) quality control records review and manufacturer instructions for use (IFU) from August 1, 2021 to September 30, 2021 and interview the laboratory director on October 5, 2021 at 12:13 PM, it was determined that the laboratory did not include an external positive and negative control material each day of COVID-19 rapid test patient testing. The findings include: a.The laboratory use the Healgen COVID-19 IgG/IgM Rapid Test Cassette to perform rapid immunology IgM/IgG patient test. b.The quality control section of the IFU stated that: additional controls may be required according to guidelines or local, state and/or federal regulations (such as 42 CFR 493.1256) or accrediting organizations. c.Review of COVID-19 IgM/IgG quality control at patient results records showed that the laboratory performs patient testing from August 1, 2021 to September 30, 2021, the laboratory did not include every day of testing the positive and the negative control materials. Instead the laboratory run the external controls once a week and when new reagent kit lot or shipment were received. d.From August 1, 2021 to September 30, 2021 the laboratory processed and reported 740 patient samples. e.The laboratory director confirmed on October 5,2021 at 12:13 PM, that the laboratory failed to include a negative and positive external control materials each day of testing. D5783

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access