Laboratorio Clinico Caribe

CLIA Laboratory Citation Details

1
Total Citation
2
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 40D2031886
Address Edificio Vale Colon, Carr Pr-111 Km 3, Hm 5, Moca, PR
City Moca
State PR
Phone(787) 818-2822

Citation History (1 survey)

Survey - March 12, 2024

Survey Type: Standard

Survey Event ID: 56ON11

Deficiency Tags: D5479 D6086

Summary:

Summary Statement of Deficiencies D5479 CONTROL PROCEDURES CFR(s): 493.1256(e)(5)(g) (e) For reagent, media, and supply checks, the laboratory must do the following: (e) (5) Follow the manufacturer's specifications for using reagents, media, and supplies and be responsible for results. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on Human chorionic gonadotropin (hCG) manufacturer's instructions, worksheet records review and laboratory supervisor interview on March 12, 2024 at 10:58 AM, it was determined that the laboratory failed to follow manufacturer's instructions to document the internal control observed results of each hCG control level material (two), when the laboratory processed patient samples. The findings include: 1. The laboratory performed (hCG) human chorionic gonadotropin by Aim Step Combo Pregnancy kit. 2. The manufacturer's instructions stated that the laboratory must monitor and document the internal control to ensure the validity of the hCG test performed. 3. The hCG test worksheet records showed on March 12, 2024 at 10:58 AM, that the laboratory did not document the observed results of the internal procedural control of each hcg control material tested when processing patient samples. 4. The laboratory processed and reported 12 hCG control material on the following dates: March 24, 2023, July 5, 2023, October 30, 2023, December 18, 2023, February 21, 2024 and March 11, 2024. A total of six patient samples were tested during the mentioned dates. 5. The laboratory supervisor confirmed on March 12, 2024 at 11:05 AM, that the laboratory failed to monitor and document the internal control of each hCG level control material when processing patient samples. D6086 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(3)(ii) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- The laboratory director must ensure that verification procedures used are adequate to determine the accuracy, precision, and other pertinent performance characteristics of the method. This STANDARD is not met as evidenced by: Based on Human chorionic gonadotropin (hCG) manufacturer's instructions, worksheet records review and laboratory supervisor interview on March 12, 2024 at 10:58 AM, it was determined that the laboratory director failed to fulfill her responsibilities and duties to ensure compliance with the manufacturer's instructions and laboratory quality control requirements. Refer to D5479. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access