Laboratorio Clinico Cuba

CLIA Laboratory Citation Details

2
Total Citations
5
Total Deficiencyies
4
Unique D-Tags
CMS Certification Number 40D1069513
Address Carr Pr-125 Km 5 Hm 2 Calle Barbosa 326, Moca, PR, 00676
City Moca
State PR
Zip Code00676
Phone(787) 818-2822

Citation History (2 surveys)

Survey - January 14, 2026

Survey Type: Standard

Survey Event ID: UF2611

Deficiency Tags: D5413 D0000 D6144 D6093

Summary:

Summary Statement of Deficiencies D0000 The Centers for Medicare & Medicaid Services (CMS) conducted an unannounced CLIA Recertification survey at the Laboratorio Clnico Cuba on January 14, 2026. The laboratory was surveyed under 42 CFR part 493 CLIA Requirements. The following standard level deficiencies were found during the unannounced routine CLIA recertification survey ending on January 14, 2026. D5413 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(b) (b) The laboratory must define criteria for those conditions that are essential for proper storage of reagents and specimens, accurate and reliable test system operation, and test result reporting. The criteria must be consistent with the manufacturer's instructions, if provided. These conditions must be monitored and documented and, if applicable, include the following: (b)(1) Water quality. (b)(2) Temperature. (b)(3) Humidity. (b)(4) Protection of equipment and instruments from fluctuations and interruptions in electrical current that adversely affect patient test results and test reports. This STANDARD is not met as evidenced by: Based on review of the ImmunoCard Mycoplasma pneumoniae manufacturer's instructions, Mycoplasma pneumoniae testing records (year 2025), and interview with the general supervisor on January 14, 2026, at 11:15 a.m., the laboratory failed to follow the manufacturer's instructions regarding the established temperature range for Mycoplasma pneumoniae testing when the laboratory processed and reported 60 of 394 patient specimens outside the manufacturer's required temperature range from January 2, 2025, through December 31, 2025. Findings include: 1. The laboratory used the ImmunoCard Mycoplasma pneumoniae qualitative test to perform Mycoplasma pneumoniae testing. 2. Review of the manufacturer's instructions established a required temperature range of 22C to 25C for test procedures. 3. Review Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- of Mycoplasma pneumoniae testing records showed that from January 2, 2025, through December 31, 2025, the laboratory processed and reported 60 of 394 patient specimens at a temperature of 21C, which was below the manufacturer's required temperature range. 4. During interview on January 14, 2026, at 11:15 a.m., the general supervisor confirmed that the laboratory processed patient specimens outside the manufacturer's established temperature range. D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) (e)(5) Ensure that the quality control and quality assessment programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur; This STANDARD is not met as evidenced by: Based on review of the Mycoplasma pneumoniae manufacturer's instructions, Mycoplasma pneumoniae testing records (year 2025), and interview with the general supervisor on January 14, 2026, at 12:00 p.m., the laboratory director failed to ensure that the manufacturer's instructions regarding the established temperature range for Mycoplasma pneumoniae testing were followed by the general supervisor, the laboratory processed and reported 60 of 394 patient specimens outside the manufacturer's required temperature range. Refer to D5413. D6144 GENERAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1463 The general supervisor is responsible for day-to-day supervision or oversight of the laboratory operation and personnel performing testing and reporting test results. This STANDARD is not met as evidenced by: Based on review of the Mycoplasma pneumoniae manufacturer's instructions, Mycoplasma pneumoniae testing records (year 2025), and interview with the laboratory general supervisor on January 14, 2026, at 12:00 p.m., the laboratory general supervisor failed to ensure that the manufacturer's instructions regarding the established temperature range for Mycoplasma pneumoniae testing were followed by testing personnel. Refer to D5413. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - February 13, 2020

Survey Type: Standard

Survey Event ID: SCR311

Deficiency Tags: D0000

Summary:

Summary Statement of Deficiencies D0000 The Laboratorio Clnico Cuba was found to be in substantial compliance with CLIA regulation (42 CFR Part 493, effective April 24, 2003). No deficiencies were cited as a result of an onsite survey performed on February 13, 2020. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 1 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access