Laboratorio Clinico Del Mar

CLIA Laboratory Citation Details

2
Total Citations
12
Total Deficiencyies
6
Unique D-Tags
CMS Certification Number 40D0705372
Address Calle Marginal Pr# 2 Urb Montecarlo #113, Vega Baja, PR, 00693
City Vega Baja
State PR
Zip Code00693
Phone(787) 858-8362

Citation History (2 surveys)

Survey - October 12, 2022

Survey Type: Standard

Survey Event ID: 4CHP11

Deficiency Tags: D6020 D6070 D5403 D6070 D5403 D6020

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - September 13, 2018

Survey Type: Standard

Survey Event ID: 8XWU11

Deficiency Tags: D5421 D5791 D5791 D6115 D5421 D6115

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of the Sysmex XN 500 verification of performance specifications documents and interview with the laboratory supervisor on September 13, 2018, it was found that the laboratory did not perform the immature granulocytes method comparison prior to use. The findings include: a. The laboratory performed the Sysmex XN 500 instrument verification performance in January 2018. b. Review of the verification performance statistical data on September 13, 2018 at 10:15 AM, showed that the laboratory did not evaluate the immature granulocytes method comparison. c. The laboratory supervisor confirmed during survey that the parameter was not included. d. Since February 2018 the laboratory received and reported 2, 385 patient's samples. D5791 ANALYTIC SYSTEMS QUALITY ASSESSMENT CFR(s): 493.1289(a)(c) (a) The laboratory must establish and follow written policies and procedures for an ongoing mechanism to monitor, assess, and when indicated, correct problems identified in the analytic systems specified in 493.1251 through 493.1283. (c) The Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- laboratory must document all analytic systems assessment activities. This STANDARD is not met as evidenced by: Based on review of the laboratory Quality Assessment Program (QA) and interview with the laboratory director on September 13, 2018. it was determined that the laboratory did not follow the established written program for comparison of test results. The findings include: a. The QA program was reviewed on September 13, 2018 at 12:10 PM. b. The QA program that evaluation of patient's test results for inconsistencies (age, sex, diagnostic and others) must be evaluated using 10 patient's results and must be every six months. c. The QA program showed that the laboratory did not evaluate the patient's inconsistencies since year 2017. d. The laboratory director stated that the QA evaluation were not performed since year 2017. D6115 TECHNICAL SUPERVISOR RESPONSIBILITIES CFR(s): 493.1451(b)(2) The technical supervisor is responsible for verification of the test procedures performed and establishment of the laboratory's test performance characteristics, including the precision and accuracy of each test and test system. This STANDARD is not met as evidenced by: Based on review of the Sysmex XN 550 instrument verification of performance specification sand interview with the laboratory supervisor on September 13, 2018, it was determined that the technical supervisor did not assure to include the evaluation of the immature granulocytes parameter method comparison when the laboratory performed the instrument performance verification. The finding includes: a. The laboratory acquired a new hematology instruments (Sysmex XN 550) however did not perform the immature granulocytes parameter method comparison. Refer to D5421. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access