Laboratorio Clinico Garcia

CLIA Laboratory Citation Details

1
Total Citation
6
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 40D0697549
Address #21 Ruiz Belvis Street, Cabo Rojo, PR, 00623
City Cabo Rojo
State PR
Zip Code00623
Phone(787) 851-1362

Citation History (1 survey)

Survey - May 9, 2024

Survey Type: Special

Survey Event ID: 519311

Deficiency Tags: D2016 D6076 D2016 D2096 D2096 D6076

Summary:

Summary Statement of Deficiencies D2016 SUCCESSFUL PARTICIPATION CFR(s): 493.803(a)(b)(c) (a) Each laboratory performing nonwaived testing must successfully participate in a proficiency testing program approved by CMS, if applicable, as described in subpart I of this part for each specialty, subspecialty, and analyte or test in which the laboratory is certified under CLIA. (b) Except as specified in paragraph (c) of this section, if a laboratory fails to participate successfully in proficiency testing for a given specialty, subspecialty, analyte or test, as defined in this section, or fails to take remedial action when an individual fails gynecologic cytology, CMS imposes sanctions, as specified in subpart R of this part. (c) If a laboratory fails to perform successfully in a CMS- approved proficiency testing program, for the initial unsuccessful performance, CMS may direct the laboratory to undertake training of its personnel or to obtain technical assistance, or both, rather than imposing alternative or principle sanctions except when one or more of the following conditions exists: (1) There is immediate jeopardy to patient health and safety. (2) The laboratory fails to provide CMS or a CMS agent with satisfactory evidence that it has taken steps to correct the problem identified by the unsuccessful proficiency testing performance. (3) The laboratory has a poor compliance history. This CONDITION is not met as evidenced by: Based on review of proficiency testing records (years 2023-2024), it was determined that the laboratory failed to attain successful participation in a Proficiency Testing Program for routine chemistry subspecialty. Refer to D2096. D2096 ROUTINE CHEMISTRY CFR(s): 493.841(f) Failure to achieve satisfactory performance for the same analyte or test in two consecutive testing events or two out of three consecutive testing events is Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- unsuccessful performance. This STANDARD is not met as evidenced by: Based on review of proficiency testing records (years 2023-2024), it was determined that the laboratory failed to achieve satisfactory performance in two out of three consecutive testing events for thyroxine (T4). The finding includes: 1.The laboratory obtained unsatisfactory results for thyroxine (T4) in second testing event for year 2023 (60%) and first testing event for year 2024 (40%). D6076 LABORATORY DIRECTOR CFR(s): 493.1441 The laboratory must have a director who meets the qualification requirements of 493. 1443 of this subpart and provides overall management and direction in accordance with 493.1445 of this subpart. This CONDITION is not met as evidenced by: Based on review of proficiency testing records (years 2023-2024), it was determined that the laboratory director failed to ensure the laboratory's successful participation in a Proficiency Testing Program for routine chemistry test. Refer to D2096. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access