Laboratorio Clinico Laurel

CLIA Laboratory Citation Details

2
Total Citations
11
Total Deficiencyies
10
Unique D-Tags
CMS Certification Number 40D1024025
Address Ave Laurel Aq 35 Santa Juanita, Bayamon, PR
City Bayamon
State PR
Phone(787) 995-3888

Citation History (2 surveys)

Survey - July 23, 2021

Survey Type: Standard

Survey Event ID: RYL011

Deficiency Tags: D6093 D5421

Summary:

Summary Statement of Deficiencies D5421 ESTABLISHMENT AND VERIFICATION OF PERFORMANCE CFR(s): 493.1253(b)(1) Each laboratory that introduces an unmodified, FDA-cleared or approved test system must do the following before reporting patient test results: (1)(i) Demonstrate that it can obtain performance specifications comparable to those established by the manufacturer for the following performance characteristics: (1)(i)(A) Accuracy. (1)(i) (B) Precision. (1)(i)(C) Reportable range of test results for the test system. (1)(ii) Verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. This STANDARD is not met as evidenced by: Based on review of validation records and laboratory director interview on July 23, 2021 at 12:05 PM, it was determined that the laboratory failed to complete the evaluation of the performance specifications of following test by the new cobas e 411 analyzer: Thyroxin (T4) free, T4 Total, triiodothyronine (T3) uptake, thyroid stimulating hormone (TSH) , Vitamin-D and prostate specific antigen (PSA) before reporting 4,192 out of 4,192 test results from October 1, 2020 to July 20, 2021. The findings include: 1. The laboratory validated the cobas e 411 analyzer on August 26, 2020 to processed the following tests since October 1, 2020: T4 free, T4 Total, T3 uptake, TSH , Vitamin-D and PSA. 2. On July 23, 2021 at 12:05 PM, the cobas e 411 analyzer validation records showed that the laboratory did not verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population before reporting patients tests. 3. The laboratory director confirmed on July 23, 2021 at 12:05 PM, that the laboratory did not verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population. 4. The laboratory processed and reported the following 4,192 patients tests from October 1, 2020 to July 20, 2021: Test Patient's tests reported a. T4 free 347 b. T4 Total 435 c. T3 uptake 337 d. TSH 1910 e. Vitamin-D 796 f. PSA 367 Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on validation records review and interview with the laboratory director on on July 23, 2021 at 12:05 PM, it was determined that the laboratory director failed to comply with the requirements of the following tests from October 1, 2020 to July 20, 2021:T4 free, T4 Total, T3 uptake, TSH , Vitamin-D and PSA. Refer to D5421 (The laboratory did not verify that the manufacturer's reference intervals (normal values) are appropriate for the laboratory's patient population before reporting patients tests). -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - May 17, 2019

Survey Type: Standard

Survey Event ID: XN2M11

Deficiency Tags: D5413 D6076 D6108 D6177 D5403 D5439 D6093 D5405 D6117

Summary:

Summary Statement of Deficiencies D5403 PROCEDURE MANUAL CFR(s): 493.1251(b) The procedure manual must include the following when applicable to the test procedure: (1) Requirements for patient preparation; specimen collection, labeling, storage, preservation, transportation, processing, and referral; and criteria for specimen acceptability and rejection as described in 493.1242. (2) Microscopic examination, including the detection of inadequately prepared slides. (3) Step-by-step performance of the procedure, including test calculations and interpretation of results. (4) Preparation of slides, solutions, calibrators, controls, reagents, stains, and other materials used in testing. (5) Calibration and calibration verification procedures. (6) The reportable range for test results for the test system as established or verified in 493.1253. (7) Control procedures. (8)

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access