Laboratorio Clinico Llanadas

CLIA Laboratory Citation Details

2
Total Citations
10
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 40D1071152
Address Carr 140 Km 67, Barceloneta, PR, 00617
City Barceloneta
State PR
Zip Code00617
Phone(787) 846-6323

Citation History (2 surveys)

Survey - November 8, 2023

Survey Type: Standard

Survey Event ID: X0WA11

Deficiency Tags: D2094 D5471 D5311 D5431 D6093 D5429 D6091 D6144

Summary:

Summary Statement of Deficiencies D2094 ROUTINE CHEMISTRY CFR(s): 493.841(e) (1) For any unsatisfactory analyte or test performance or testing event for reasons other than a failure to participate, the laboratory must undertake appropriate training and employ the technical assistance necessary to correct problems associated with a proficiency testing failure. (2) For any unacceptable analyte or testing event score, remedial action must be taken and documented, and the documentation must be maintained by the laboratory for two years from the date of participation in the proficiency testing event. This STANDARD is not met as evidenced by: Based on Puerto Rico Proficiency Testing (PRPT) records review ( year 2022-2023 ) and laboratory general supervisor interview on November 8, 2023 at 10:15 A.M. , it was determined that the laboratory failed to take and document

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - December 7, 2021

Survey Type: Standard

Survey Event ID: O6LN11

Deficiency Tags: D6093 D5449

Summary:

Summary Statement of Deficiencies D5449 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(ii)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each qualitative procedure, include a negative and positive control material; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on General Immunology (Mycoplasma pneumoniae test) testing records review from October 27, 2021 to December 6, 2021 and interview with the laboratory supervisor on December 7, 2021 at 9:59 AM, it was determined that the laboratory did not include an external positive and negative control material when 16 out of 16 patients specimens were tested and reported for Mycoplasma pneumoniae from October 27, 2021 to December 6, 2021. The findings include: 1. The laboratory use the Immuno Card Mycoplasma Test Cassette to perform the Mycoplasma pneumoniae qualitative tests. 2. On December 7, 2021 at 9:59 AM, Mycoplasma pneumoniae testing record review showed that the laboratory performs and report patient sample from October 27, 2021 to December 6, 2021. The laboratory did not include a external positive and negative control each day of patient testing. 3. The laboratory supervisor confirmed on December 7, 2021 at 9:59 AM, that the laboratory failed to include each day of patient testing an external negative and positive control material . She stated that the laboratory run the external controls when it received a new reagent kit. 4. The laboratory processed and reported 16 patients specimens for Mycoplasma pneumoniae from October 27, 2021 to December 6, 2021. D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- The laboratory director must ensure that the quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. This STANDARD is not met as evidenced by: Based on Mycoplasma pneumonia rapid test quality control records and interview with the laboratory supervisor on December 7, 2021 at 9:59 AM, it was determined that the laboratory director did not assure that external control was run each day of patient testing. Refer to D5449. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access