Laboratorio Clinico Migrant San German

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
2
Unique D-Tags
CMS Certification Number 40D0856733
Address Ave Universidad Interamericana 158, Bo Pueblo, San German, PR, 00683
City San German
State PR
Zip Code00683
Phone(787) 892-5565

Citation History (1 survey)

Survey - February 22, 2022

Survey Type: Standard

Survey Event ID: BGJ011

Deficiency Tags: D6093 D5449 D6093

Summary:

Summary Statement of Deficiencies D5449 CONTROL PROCEDURES CFR(s): 493.1256(d)(3)(ii)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- At least once a day patient specimens are assayed or examined perform the following for-- Each qualitative procedure, include a negative and positive control material; (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: Based on endocrinology quality control records review (year 2021) and interview with the laboratory supervisor it was determined that the laboratory failed to include a negative and positive external control material when performed hCG (Human Chrorionic Gonadotropin) tests. The finding include : a. Endocrinology quality control logs were reviewed on February 22, 2022 at 2:23 PM from January to November 2021. b. Review of records showed that the laboratory did not include a positive nor a negative external control material when patient's test were performed from January 5, 2021 to November 24, 2021. The laboratory processed and reported 11 out of 12 patient. c. The laboratory supervisor on February 22, 2022 at 2:23 PM, stated that the laboratory only run external control with each new lot kit. D6093 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1445(e)(5) The laboratory director must ensure that the quality control programs are established and maintained to assure the quality of laboratory services provided and to identify failures in quality as they occur. Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- This STANDARD is not met as evidenced by: Based on endocrinology quality control records review (years 2021) and laboratory general supervisor interview it was found that the laboratory director did not assure that quality control procedures were followed. The findings include: 1. On February 22, 2022 at 2:25 PM the laboratory supervisor confirmed that the laboratory did not run an external positive and negative control each day of patient testing. Refer to D5449. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access