Laboratorio Clinico Shaddai

CLIA Laboratory Citation Details

2
Total Citations
9
Total Deficiencyies
9
Unique D-Tags
CMS Certification Number 40D2059616
Address Carr 2, Km 99 Bo Cocos, Quebradillas, PR
City Quebradillas
State PR
Phone(787) 895-6173

Citation History (2 surveys)

Survey - August 4, 2023

Survey Type: Standard

Survey Event ID: 4IT111

Deficiency Tags: D5024 D5439 D6000 D5405 D6020 D5469

Summary:

Summary Statement of Deficiencies D5024 HEMATOLOGY CFR(s): 493.1215 If the laboratory provides services in the specialty of Hematology, the laboratory must meet the requirements specified in 493.1230 through 493.1256, 493.1269, and 493. 1281 through 493.1299. This CONDITION is not met as evidenced by: Based on hematology quality control records review ( year 2022-2023 ) and interview with the laboratory director on August 4, 2023 at 12:30 P.M. , it was determined that the laboratory failed to ensure compliance with the analytic system requirements for hematology. Refer D5469 1. The laboratory did not evaluate nor define the statistical values of all the lot numbers of the commercial control material used by the Cell Dyn 1700 instrument since July 2022.) 2. The laboratory failed to verify the stated value of the new lot CBC commercially assayed control materials from July 2022 to August 2023. D5405 PROCEDURE MANUAL CFR(s): 493.1251(c) Manufacturer's test system instructions or operator manuals may be used, when applicable, to meet the requirements of paragraphs (b)(1) through (b)(12) of this section. Any of the items under paragraphs (b)(1) through (b)(12) of this section not provided by the manufacturer must be provided by the laboratory. This STANDARD is not met as evidenced by: Based on Immuno Card Mycoplasma manufacturer's instructions, Mycoplasma testing records review ( year 2023 ) and laboratory director interview on August 4, 2023 at 11: 00 A.M., , it was determined that the laboratory failed to follow the manufacturer's Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 4 -- instruction when 127 out of 127 patient specimen were tested for Mycoplasma by Immuno Card Meridian method. The findings include: 1. The manufacturer's instruction establishes to perform the test procedures at room temperature from 22 to 25 C. 2. On August 4, 2023 at 11:05 A.M., the Mycoplasma testing records showed that the laboratory did not monitor nor documented the room temperature when it processed Mycoplasma patients specimens. 3. The laboratory director confirmed on August 4, 2023 at 11:10 A.M., that the laboratory did not follow the manufacture's instructions for the temperature of processing. 4. The laboratory processed and reported 127 out of 127 patient specimen for mycoplasma test out of the manufacturer's temperature ranged in year 2023. D5439 CALIBRATION AND CALIBRATION VERIFICATION CFR(s): 493.1255(b) Unless otherwise specified in this subpart, for each applicable test system the laboratory must do the following: Perform and document calibration verification procedure - (b)(1) Following the manufacturer's calibration verification instructions; (b)(2) Using the criteria verified or established by the laboratory under 493.1253(b)(3) -- (b)(2)(i) Including the number, type, and concentration of the materials, as well as acceptable limits for calibration verification; and (b)(2)(ii) Including at least a minimal (or zero) value, a mid-point value, and a maximum value near the upper limit of the range to verify the laboratory's reportable range of test results for the test system; and (b)(3) At least once every 6 months and whenever any of the following occur: (b)(3)(i) A complete change of reagents for a procedure is introduced, unless the laboratory can demonstrate that changing reagent lot numbers does not affect the range used to report patient test results, and control values are not adversely affected by reagent lot number changes. (b)(3)(ii) There is major preventive maintenance or replacement of critical parts that may influence test performance. (b)(3)(iii) Control materials reflect an unusual trend or shift, or are outside of the laboratory's acceptable limits, and other means of assessing and correcting unacceptable control values fail to identify and correct the problem. (b)(3)(iv) The laboratory's established schedule for verifying the reportable range for patient test results requires more frequent calibration verification. This STANDARD is not met as evidenced by: Based on routine chemistry calibration verification records review (year 2022-2023) and interview with the laboratory director on August 4, 2023 at 10:45 A.M., it was determined that the laboratory did not perform , at least every 6 months, the calibration verification procedures for the routine chemistry (lipid panel and glucose) tests processed by the Daytona system. The findings include: 1. The laboratory used the Daytona system to perform lipid panel and glucose tests. 2. Review of routine chemistry calibration verification records showed that the laboratory did not perform the lipid panel and glucose calibration verification procedure since June 2022. 3. The laboratory director confirmed on August 4, 2023 at 10:55 A.M., that the laboratory did not perform , at least every 6 months, the calibration verification procedures for the routine chemistry tests. The laboratory processed and reported since June 2022 the following patient samples : 822 lipid panel and 23 glucose test. D5469 CONTROL PROCEDURES CFR(s): 493.1256(d)(10)(g) Unless CMS Approves a procedure, specified in Appendix C of the State Operations -- 2 of 4 -- Manual (CMS Pub. 7), that provides equivalent quality testing, the laboratory must-- Establish or verify the criteria for acceptability of all control materials. (i) When control materials providing quantitative results are used, statistical parameters (for example, mean and standard deviation) for each batch and lot number of control materials must be defined and available. (ii) The laboratory may use the stated value of a commercially assayed control material provided the stated value is for the methodology and instrumentation employed by the laboratory and is verified by the laboratory. (iii) Statistical parameters for unassayed control materials must be established over time by the laboratory through concurrent testing of control materials having previously determined statistical parameters. (g) The laboratory must document all control procedures performed. This STANDARD is not met as evidenced by: 1. Based on hematology quality control values review ( July 2022-August 2023 ) and interview with the laboratory director on August 4, 2023 at 11:30 A.M. , it was found that the laboratory did not evaluate nor define the statistical values of all the lot numbers of the commercial control material used by the Cell Dyn 1700 instrument since July 2022. The findings include: a. The laboratory did not have any statistical data (Levy-Jennings, control value mean and limits) of the control materials used since July 2022. b. The Cell Dyn 1700 system showed the quality control ( low , normal and high ) , however, the laboratory director confirmed that the laboratory did not evaluate any control in Levey Jenny graphs since July 2022, due the laboratory did not have printer. c. The hematology lot number used were : Lot : 23530422, 23530423, 23530424 ( 7/22/2022 - 8/26/2022 ) 31560422, 31560423, 3156024 ( 02/23 /2023- 8/4/23 ) d. The laboratory did not have any recorded information (paper or electronically) of the lot numbers used from 8/27/022 to 2/22/202.. e. The laboratory processed and reported 1,261 Complete blood cell ( CBC ) in 2022. f. During the survey performed on August 4, 2023, the laboratory director confirmed that the laboratory did not evaluate control results to detect any outliers, shifts or trends in control values since July 2022. 2. Based on complete cell count (CBC) quality control records review in Cell Dyn system and interview with the laboratory director on August 4, 2023 at 12 : 00 P. M , it was determined that the laboratory failed to verify the stated value of the new lot CBC commercially assayed control materials from July 2022 to August 2023. The finding include : a. The CBC quality control records showed that the laboratory did not verify the new lots of CBC control materials (lot 350307-42 and 350307-43) prior to placed in routine on April 1, 2022 and February 2023, respectively. b. The laboratory director confirmed on August 4, 2023 at 12: 15. P.M. that the laboratory did not verify those new lots of CBC control materials prior to placed in routine. c. The laboratory processed and reported 1,261 Complete blood cell ( CBC ) in 2022. D6000 MODERATE COMPLEXITY LABORATORY DIRECTOR CFR(s): 493.1403 The laboratory must have a director who meets the qualification requirements of 493. 1405 of this subpart and provides overall management and direction in accordance with 493.1407 of this subpart. This CONDITION is not met as evidenced by: -- 3 of 4 -- Based on review of hematology quality control records review on August 4, 2023 at 1: 00 P.M. it was determined that the laboratory director failed to fulfill her responsibilities with the hematology analytic requirements. Refer to D6020. D6020 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(5) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(5) Ensure that the quality control program is established and maintained to assure the quality of laboratory services provided. This STANDARD is not met as evidenced by: Based on hematology, routine chemistry and general Immunology quality control records review ( year 2022-2023 ) on August 4, 2023 at 12:30 P.M. and laboratory director interview on August 4, 2023 at 12:30 P.M. , it was determined that laboratory director failed to ensure compliance with the requirements for analytic systems. The findings include : 1.The laboratory failed to follow the manufacturer's instruction when 127 out of 127 patient specimen were tested for Mycoplasma by Immuno Card Meridian method. ( Refer to D5405 ) 2. The laboratory did not perform , at least every 6 months, the calibration verification procedures for the routine chemistry (lipid panel and glucose) tests processed by the Daytona system. ( Refer to D5439 ) 3. The laboratory did not evaluate nor define the statistical values of all the lot numbers of the commercial control material used by the Cell Dyn 1700 instrument since July 2022. ( Refer to D5469 ) 4. The laboratory failed to verify the stated value of the new lot CBC commercially assayed control materials from July 2022 to August 2023. ( Refer to D5469 ) -- 4 of 4 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access

Survey - August 23, 2019

Survey Type: Standard

Survey Event ID: L89S11

Deficiency Tags: D6016 D2123 D2067

Summary:

Summary Statement of Deficiencies D2067 SYPHILIS SEROLOGY CFR(s): 493.835(b) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on Puerto Rico Proficiency Testing Program records reviewed ( 2018-2019) laboratory director interview on August 23, 2019 at 10: 00 A.M., it was determined that the laboratory failed to participate in the syphilis serology second testing event performed in August 2018. The findings include: 1. Proficiency testing records were reviewed from February 2018 to July 2019. 2. The laboratory did not participate in the second testing event of syphilis serology performed in August 2018 established by the Proficiency Testing Program. 3. The laboratory director confirmed on August 23, 2019 at 10:00 A.M., that the laboratory failed to participate in the second testing event of syphilis serology specialty in August 2018. D2123 HEMATOLOGY CFR(s): 493.851(c) Failure to participate in a testing event is unsatisfactory performance and results in a score of 0 for the testing event. Consideration may be given to those laboratories failing to participate in a testing event only if-- (1) Patient testing was suspended Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- during the time frame allotted for testing and reporting proficiency testing results; (2) The laboratory notifies the inspecting agency and the proficiency testing program within the time frame for submitting proficiency testing results of the suspension of patient testing and the circumstances associated with failure to perform tests on proficiency testing samples; and (3) The laboratory participated in the previous two proficiency testing events. This STANDARD is not met as evidenced by: Based on American Association of Bioanalysts (AAB) Testing Program records reviewed ( 2018-2019) laboratory director interview on August 23, 2019 at 10: 00 A. M., it was determined that the laboratory failed to participate in the hematology first testing event performed in February 2019. The findings include: 1. Proficiency testing records were reviewed from February 2018 to July 2019. 2. The laboratory did not participate in the first testing event of hematology performed in February 2019 established by the AAB Proficiency Testing Program. 3. The laboratory director confirmed on August 23, 2019 at 10:00 A.M., that the laboratory failed to participate in the first testing event of hematology specialty in February 2019. D6016 LABORATORY DIRECTOR RESPONSIBILITIES CFR(s): 493.1407(e)(4)(i) The laboratory director is responsible for the overall operation and administration of the laboratory, including the employment of personnel who are competent to perform test procedures, and record and report test results promptly, accurate, and proficiently and for assuring compliance with the applicable regulations. (e) The laboratory director must-- (e)(4)(i) Ensure that the proficiency testing samples are tested as required under Subpart H of this part; This STANDARD is not met as evidenced by: Based on Puerto Rico proficiency testing records review ( 2018-2019) and laboratory director interview on August 23, 2019 at 10:00 A.M., it was determined that the laboratory failed to ensure that proficiency testing samples were tested as required under Subpart H requirements. Refer to D 2067 and D2123. -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access