Larkin Mohs Laboratory

CLIA Laboratory Citation Details

1
Total Citation
3
Total Deficiencyies
3
Unique D-Tags
CMS Certification Number 10D2086344
Address 6140 Sw 70 St, 2nd Fl, South Miami, FL, 33143
City South Miami
State FL
Zip Code33143
Phone(305) 284-7577

Citation History (1 survey)

Survey - December 16, 2020

Survey Type: Standard

Survey Event ID: UZAV11

Deficiency Tags: D0000 D5417 D3031

Summary:

Summary Statement of Deficiencies D0000 A recertification survey was completed on 12/14/2020 to 12/16/2020 at LARKIN MOHS LABORATORY. The laboratory was not in compliance with 42 CFR Part 493, Requirements for Laboratories. D3031 RETENTION REQUIREMENTS CFR(s): 493.1105(a)(3) Analytic systems records. Retain quality control and patient test records (including instrument printouts, if applicable) and records documenting all analytic systems activities specified in 493.1252 through 493.1289 for at least 2 years. This STANDARD is not met as evidenced by: Based on record review and interview , the laboratory failed to provide documentation of MOHS tissue mapping for patients S18-14060 and 19-004 onsite. Findings Included : Review of Patient Reports revealed MOHS maps were missing from S18- 14060 and 19-004 patient records . During an interview conducted on 12/14/2020 at 1: 54pm , the laboratory consultant confirmed no documentation of MOHS map for tissue mapping for patient S18-14060 and 19-004 onsite. D5417 TEST SYSTEMS, EQUIPMENT, INSTRUMENTS, REAGENT CFR(s): 493.1252(d) Reagents, solutions, culture media, control materials, calibration materials, and other supplies must not be used when they have exceeded their expiration date, have deteriorated, or are of substandard quality. This STANDARD is not met as evidenced by: Based on observation and interview , the laboratory failed to have dyes , reagent alcohol and liquid submount that were not expired onsite. Findings Included: Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number (X3) Date Survey Completed Name of Provider or Supplier Street Address, City, State -- 1 of 2 -- Observation of the laboratory revealed red, blue, yellow and black dye inks expiring after 9-01-2020 on the counter. A biohazard cabinet contained liquid submount and reagent alcohol that expired after 9-30-19. During an interview conducted on 12/14 /2020 at 1:54pm , the laboratory consultant confirmed dyes , reagent alcohol and liquid submount were expired onsite . -- 2 of 2 --

πŸ”’ Unlock Deficiency Summary

Get full access to the detailed deficiency summary for this facility

One-time payment β€’ Lifetime access